Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Podręcznik Użytkownika Strona 452

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 931
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 451
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR49
Message The dedicated hot spare
arg1
is too small.
Arguments
arg1 =
PD Name
Detailed
Description
The dedicated hot spare is not large enough to protect all virtual disks that reside on the disk
group.
Recommended
Response Action
Assign a larger disk as the dedicated hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR50
Message Insufficient space on the global hot spare
arg1
.
Arguments
arg1 =
PD Name
Detailed
Description
The global hot spare is not large enough to protect all virtual disks that reside on the controller.