Dell OpenManage Server Administrator Version 6.5 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Serwery Dell OpenManage Server Administrator Version 6.5. Dell OpenManage Server Administrator Version 6.5 Command Line Interface Guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 282
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Interface Guide

Dell OpenManageServer AdministratorVersion 6.5Command LineInterface Guide

Strona 2 - Notes and Cautions

10 Contentsomreport Fan Status . . . . . . . . . . . . . . . . 184omreport Power Supply Status . . . . . . . . . . . 185omreport EMM Status . . . .

Strona 3 - Contents

100 omconfig: Managing Componentsattribute=nic1 setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsienabled:

Strona 4 - 4 Contents

omconfig: Managing Components 101attribute=nic3 setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsienabled:

Strona 5

102 omconfig: Managing Componentsattribute=numlocksetting=on | off on: Uses the keypad as number keys.off: Uses the keypad as arrow keys.attribute=num

Strona 6 - 6 Contents

omconfig: Managing Components 103attribute=romb setting=raid | off | scsiforce=trueraid: Instructs the BIOS to detect RAID-on-motherboard as a RAID de

Strona 7

104 omconfig: Managing Componentsattribute=secondaryscsisetting=on | off on: Enables this device.off: Disables this device.attribute=serialportaddrset

Strona 8 - 8 Contents

omconfig: Managing Components 105attribute=serialport1setting=off | auto | com1 | com3 | bmcserial | bmcnic | rac | com1bmcoff: Disables serial port 1

Strona 9

106 omconfig: Managing Componentsattribute=uausb setting=on | backonly | offon: Enables the user-accessible USB port(s).backonly: Enables only the use

Strona 10 - 10 Contents

omconfig: Managing Components 107omconfig chassis currents/omconfig mainsystem currents NOTE: This command is no longer available through Server Admi

Strona 11

108 omconfig: Managing ComponentsSpecifying a Value for Minimum and Maximum Warning ThresholdsIf you prefer to specify values for the fan probe warnin

Strona 12 - 12 Contents

omconfig: Managing Components 109• Ambient temperature of the system• Remote access IPv4 address• Remote access IPv6 address• Specify and configure th

Strona 13 - Command Results

Contents 11omconfig Pause Check Consistency . . . . . . . . 205omconfig Resume Check Consistency . . . . . . . 205omconfig Blink Virtual Disk . . .

Strona 14 - 14 Contents

110 omconfig: Managing Components NOTE: The options ipv4idrac, ipv6idrac, and macidrac are deprecated.omconfig chassis info/omconfig mainsystem infoU

Strona 15 - Introduction

omconfig: Managing Components 111Index 0 always defaults to the main system chassis. The following command omits index=n, but accomplishes the same th

Strona 16

112 omconfig: Managing Componentsomconfig chassis memorymode/omconfig mainsystem memorymodeUse the omconfig chassis memorymode or omconfig mainsystem

Strona 17

omconfig: Managing Components 113Table 4-8 shows the valid parameters for the command.Table 4-8. omconfig chassis memorymode/omconfig mainsystem memor

Strona 18 - Primary CLI Commands

114 omconfig: Managing Componentsomconfig chassis pwrmanagement/omconfig mainsystem pwrmanagementUse the omconfig chassis pwrmanagement or omconfig ma

Strona 19 - Success Messages

omconfig: Managing Components 115 NOTE: Reboot your system for the power profiles setup options to take effect.cpupowermode=min | max | systemdbpm |

Strona 20 - Failure Messages

116 omconfig: Managing Componentsomconfig chassis pwrmonitoring/omconfig mainsystem pwrmonitoringUse the omconfig chassis pwrmonitoring or omconfig ma

Strona 21 - Introduction 21

omconfig: Managing Components 117Specify a Value for Warning ThresholdsIf you prefer to specify values for the power consumption probe warning thresho

Strona 22

118 omconfig: Managing ComponentsThe output of the omconfig chassis remoteaccess or omconfig mainsystem remoteaccess command lists each of the availab

Strona 23 - Command Syntax Overview

omconfig: Managing Components 119dnssourcev6=static | auto static: DNS source is set to static.auto: DNS source is set to auto.config=nic (continued)e

Strona 24 - 24 Introduction

12 Contentsomconfig Set Background Initialization Rate. . . . . . . . . . . . . . . . . . 233omconfig Set Reconstruct Rate . . . . . . . . . . 233om

Strona 25 - Using the omhelp Command

120 omconfig: Managing Componentsipsourcev6=static | auto static: IPv6 address source is set to static.auto: IPv6 address source is set to auto.config

Strona 26

omconfig: Managing Components 121config=serial baudrate=9600 | 19200 | 38400 | 57600 | 1152009600: Sets the connection speed to 9600 bits per second.

Strona 27

122 omconfig: Managing Componentsconfig=serial (continued)mode=directbasic | directterminal | directbasicterminal | modembasic | modemterminal | modem

Strona 28 - 28 Using the omhelp Command

omconfig: Managing Components 123config=serialoverlan enable=true | false true: Enables serial over LAN for the BMC. false: Disables serial over LAN f

Strona 29

124 omconfig: Managing Componentsprivilegelevel=administrator | operator | useradministrator: Sets the maximum privilege level that can be accepted on

Strona 30

omconfig: Managing Components 125newlinesequence=none | crlf | null | cr | lfcr | lfnone: BMC does not use a termination sequence.crlf: BMC uses <C

Strona 31

126 omconfig: Managing Componentsid=number newpw=text confirmnewpw=textid=number: ID (in numeric format) of the user being configured.newpw=text: New

Strona 32

omconfig: Managing Components 127id=user id dracusergroup=admin | poweruser | guest | custom | noneid=user id: User ID of the user being configured.dr

Strona 33

128 omconfig: Managing ComponentsTable 4-12. omconfig chassis remoteaccess config=user id=<user id> dracusergroup=custom/omconfig mainsystem rem

Strona 34

omconfig: Managing Components 129omconfig chassis temps/omconfig mainsystem tempsUse the omconfig chassis temps or omconfig mainsystem temps command t

Strona 35

Contents 13omconfig Reset Temperature Probe Thresholds . . . . . . . . . . . . . . . . . 248omconfig Set All Temperature Probe Thresholds . . . . . .

Strona 36

130 omconfig: Managing ComponentsSpecify a Value for Minimum and Maximum Warning ThresholdsIf you want to specify values for the temperature probe war

Strona 37 - <command level 2> -?

omconfig: Managing Components 131Default Minimum and Maximum Warning Threshold ValuesIf you want to set both the upper and lower voltage warning thres

Strona 38

132 omconfig: Managing ComponentsWhen you issue the command and the system sets the values you specify, the following message appears:Voltage probe wa

Strona 39 - Commands

omconfig: Managing Components 133Therefore, for a computer named "myOmsa" running Server Administrator, the default name would be "myOm

Strona 40

134 omconfig: Managing Components CAUTION: Interactive mode is the more encrypted method of setting the SNMP root password. In non-interactive mode,

Strona 41

omconfig: Managing Components 135For example, to disallow SNMP set operations use the following command:omconfig preferences snmp setting=snmpset enab

Strona 42 - Parameters Description

136 omconfig: Managing ComponentsTable 4-20 shows the name=value pairs you can use with this command.Table 4-20. Configuring Webserver PreferencesFor

Strona 43

omconfig: Managing Components 137omconfig system/omconfig servermoduleUse the omconfig system or omconfig servermodule commands to clear logs, determi

Strona 44

138 omconfig: Managing ComponentsThe event is a power supply failure and the action is to broadcast a message to all Server Administrator users.Availa

Strona 45

omconfig: Managing Components 139event=fanwarn Sets actions when a fan probe detects a warning value.event=fanfail Sets actions when a fan probe detec

Strona 46 - Critical

14 ContentsWriting Command Output to a File . . . . . . . . . . . 262Saving Command Results to a File That Can Be Overwritten. . . . . . . . . . . .

Strona 47

140 omconfig: Managing Components NOTE: storagectrlbatterywarn and storagectrlbatteryfail events are not available on modular systems.Example Set Ale

Strona 48

omconfig: Managing Components 141Example Current Probe ActionsTo disable system console alert if a current probe detects a warning event, type:omconfi

Strona 49

142 omconfig: Managing ComponentsCommands for Clearing Logs NOTE: For more information about alert messages, see the Dell OpenManage Server Administr

Strona 50

omconfig: Managing Components 143omconfig system platformevents/omconfig servermodule platformeventsUse the omconfig system platformevents or omconfig

Strona 51

144 omconfig: Managing ComponentsTable 4-25 lists the components and the events for which you can set platform events. Components are listed in alphab

Strona 52

omconfig: Managing Components 145event=intrusion Sets action or enables/disables alert generation when a chassis is opened.event=powerwarn Sets actio

Strona 53

146 omconfig: Managing Componentsomconfig system events/omconfig servermodule eventsUse the omconfig system events or omconfig servermodule events com

Strona 54

omconfig: Managing Components 147SourceAt present, source=snmptraps is a required name=value pair because SNMP is currently the only supported source

Strona 55

148 omconfig: Managing ComponentsSeverityIn the context of configuring events, severity determines how severe an event must be before Server Administr

Strona 56 - Server Administrator

omconfig: Managing Components 149IndexIndex refers to the number of an event for a particular component. Index is an optional parameter. When you omit

Strona 57

Introduction 151IntroductionOverviewDell OpenManage Server Administrator (OMSA) provides a comprehensive, one-to-one systems management solution in tw

Strona 58

150 omconfig: Managing ComponentsExample Recovery CommandsTo set the action on hung operating system detection to powercycle, type:omconfig system rec

Strona 59

omconfig: Managing Components 151omconfig system shutdown/omconfig servermodule shutdownUse the omconfig system shutdown or omconfig servermodule shut

Strona 60

152 omconfig: Managing ComponentsTo bypass operating system shutdown before the system is powered off, type:omconfig system shutdown action=reboot osf

Strona 61

omconfig: Managing Components 153To disable thermal shutdown so that an administrator has to initiate an omconfig system shutdown, type:omconfig syste

Strona 62

154 omconfig: Managing Components

Strona 63

omconfig system or servermodule 1555omconfig system or servermodule assetinfo: Editing Cost of Ownership Values The omconfig system assetinfo or omcon

Strona 64

156 omconfig system or servermoduleTable 5-2. omconfig system assetinfo info=acquisition/omconfig servermodule assetinfo info=acquisitionCommand Level

Strona 65

omconfig system or servermodule 157Example Commands for Adding Acquisition InformationTo provide a value for an acquisition parameter, type a command

Strona 66 - Commands for Viewing Logs

158 omconfig system or servermoduleAdding Depreciation InformationDepreciation is a set of methods for computing the devaluation of your asset over ti

Strona 67

omconfig system or servermodule 159omconfig system assetinfo info=depreciation method=straightlineoromconfig servermodule assetinfo info=depreciation

Strona 68

16 IntroductionThe reporting and viewing features allow retrieval of overall health status for systems on your network. At the component level, you ca

Strona 69

160 omconfig system or servermoduleTable 5-4 shows the valid parameters for the command.Example Command for Adding Extended Warranty InformationTo pro

Strona 70 - <component name>

omconfig system or servermodule 161You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, a

Strona 71

162 omconfig system or servermoduleExample Command for Adding Lease InformationTo provide a value for a lease parameter, type a command of the form: o

Strona 72 - Output Attributes Description

omconfig system or servermodule 163Example Command for Adding Maintenance InformationTo provide a value for a maintenance parameter, type a command of

Strona 73

164 omconfig system or servermoduleAdding Outsource InformationOutsourcing is the practice of contracting with another business to maintain the system

Strona 74 - Example Command Output

omconfig system or servermodule 165Example Command for Adding Outsource InformationTo provide a value for an outsource parameter, type a command of th

Strona 75

166 omconfig system or servermoduleExample Command for Adding Owner InformationTo provide a value for an owner parameter, type a command of the form:

Strona 76

omconfig system or servermodule 167Adding Service Contract InformationA service contract is an agreement that specifies fees for preventive maintenanc

Strona 77

168 omconfig system or servermoduleYou can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, a

Strona 78 - Remote Access Information

omconfig system or servermodule 169Example Command for Adding Support InformationTo provide a value for a support parameter, type a command of the for

Strona 79 - Memory Array

Introduction 17• Deprecated the following operating systems:– Red Hat Enterprise Linux 4.x– VMware ESX 4.0 U2 – VMware ESX 4.1 – VMware ESXi 4.0 U2 –

Strona 80 - Firmware

170 omconfig system or servermoduleAdding System InformationSystem information includes the primary user of the system, the phone number for the prima

Strona 81

omconfig system or servermodule 171You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, a

Strona 82

172 omconfig system or servermoduleExample Command for Adding Warranty InformationTo provide a value for a warranty parameter, type a command of the f

Strona 83

Using the Storage Management 1736Using the Storage Management ServiceThe CLI of Storage Management enables you to perform reporting, configuration, an

Strona 84

174 Using the Storage ManagementTable 6-1 describes these command levels.Following the command levels, the omreport and omconfig command syntax may re

Strona 85

Using the Storage Management 175Table 6-2. Syntax For Name=Value Pairs For ParametersSyntax Description controller=id Indicates the controller ID as r

Strona 86

176 Using the Storage ManagementUser Privileges for omreport storage and omconfig storageStorage Management requires Administrator privileges to use t

Strona 87 - NOTE: You cannot change

omreport storage Commands 1777omreport storage Commands The omreport command allows you to view storage component information for disks, controllers,

Strona 88

178 omreport storage Commandsomreport Physical Disk Status Table 7-2 describes the syntax for the omreport Physical Disk Commands.battery Displays a l

Strona 89

omreport storage Commands 179cachecade=idwhere id is the cachecade number. For example: cachecade=1Displays all physical disks included in the specifi

Strona 90

18 IntroductionUsing CLI Commands From Windows Command PromptsIf you are running the Microsoft Windows operating system, use the 32-bit command prompt

Strona 91

180 omreport storage Commandsomreport Virtual Disk Status Table 7-3 describes the syntax for the omreport Virtual Disk Commands.Table 7-3. omreport Vi

Strona 92

omreport storage Commands 181omreport Controller StatusTable 7-4 describes the syntax for the omreport Controller Commands.Table 7-4. omreport Control

Strona 93

182 omreport storage Commandsomreport Enclosure Status Table 7-5 describes the syntax for the omreport Enclosure Commands.Table 7-5. omreport Enclosur

Strona 94

omreport storage Commands 183The following sections provide the omreport storage enclosure command syntax required to execute the enclosure commands.o

Strona 95

184 omreport storage Commandsomreport Fan StatusTable 7-7 describes the syntax for the omreport Fan Commands.Table 7-7. omreport Fan StatusRequired Co

Strona 96

omreport storage Commands 185omreport Power Supply StatusTable 7-8 describes the syntax for the omreport Power Supply Commands.Table 7-8. omreport Pow

Strona 97

186 omreport storage Commandsomreport EMM Status NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmwar

Strona 98

omreport storage Commands 187omreport Enclosure Slot Occupancy ReportTable 7-10 describes the syntax for the omreport Enclosure Slot Occupancy Report

Strona 99 - NOTE: The

188 omreport storage Commandsomreport Global Information (Smart Thermal Shutdown Status, Hot Spare Protection Policy)Table 7-12 describes the syntax f

Strona 100 - (continued)

omreport storage Commands 189omreport Connector Status Table 7-13 describes the syntax for the omreport Connector Commands.Table 7-13. omreport Connec

Strona 101

Introduction 19 NOTE: omupdate commands are no longer supported in Server Administrator and are replaced by Dell Update Package or Server Update Util

Strona 102

190 omreport storage Commandsomreport Cachecade Status Table 7-14 describes the syntax for the omreport Cachecade Commands. NOTE: The cachecade featu

Strona 103

omconfig storage Commands 1918omconfig storage CommandsThe omconfig commands allows you to configure physical disks, virtual disks, controllers, enclo

Strona 104

192 omconfig storage Commandsomconfig Physical Disk Commands The following sections provide the omconfig command syntax required to execute physical d

Strona 105

omconfig storage Commands 193omconfig Blink Physical Disk You can blink the light (light emitting diode or LED display) on one or more physical disks

Strona 106

194 omconfig storage CommandsComplete Syntax omconfig storage pdisk action=unblink controller=id pdisk=<PDISKID> where id is the controller ID.

Strona 107

omconfig storage Commands 195Example Syntax In this example, you want to prepare physical disk 3 on connector 0 of controller 1 for removal. On a SAS

Strona 108

196 omconfig storage CommandsExample for SCSI, SATA, and ATA Controllers To erase the physical disk described in this example, type: omconfig storage

Strona 109

omconfig storage Commands 197To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdi

Strona 110

198 omconfig storage CommandsExample for SCSI, SATA, and ATA Controllers To bring the physical disk described in this example back online, type: omcon

Strona 111

omconfig storage Commands 199Example for SAS Controllers To assign the physical disk described in this example as a global hot spare, type: omconfig s

Strona 112

Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potenti

Strona 113

20 IntroductionMessage:Temperature probe warning threshold value(s) set successfully.Command:omconfig chassis biossetup attribute=numlock setting=on M

Strona 114

200 omconfig storage Commandsomconfig Cancel Rebuild Physical DiskUse the following omconfig command syntax to cancel a rebuild that is in progress. I

Strona 115

omconfig storage Commands 201omconfig Cancel Replace MemberUse the following omconfig command syntax to cancel a replace member operation. Complete Sy

Strona 116 - Default Warning Thresholds

202 omconfig storage CommandsExample for SAS Controllers To clear the physical disk described in this example, type: omconfig storage pdisk action=cle

Strona 117

omconfig storage Commands 203Table 8-3. omconfig Manage Virtual Disk CommandsRequired Command Levels (1, 2, 3) Optional name=value pairs omconfig stor

Strona 118

204 omconfig storage Commandsomconfig Check Consistency Use the following omconfig command syntax to initiate a check consistency on a virtual disk. T

Strona 119

omconfig storage Commands 205omconfig Pause Check Consistency Use the following omconfig command syntax to pause a check consistency while in progress

Strona 120

206 omconfig storage Commandsomconfig Blink Virtual Disk Use the following omconfig command syntax to blink the physical disks included in a virtual d

Strona 121

omconfig storage Commands 207omconfig Initialize Virtual Disk Use the following omconfig command syntax to initialize a virtual disk. Complete Syntax

Strona 122

208 omconfig storage CommandsExample Syntax To fast initialize virtual disk 4 on controller 1, type: omconfig storage vdisk action=fastinit controller

Strona 123

omconfig storage Commands 209omconfig Cancel Initialize Virtual Disk Use the following omconfig command syntax to cancel the initialization of a virtu

Strona 124

Introduction 21Example message:Error! Number with up to 3 digits after decimal point expected, read 3.3000The value given by the command specifies mor

Strona 125

210 omconfig storage Commandsomconfig Assign Dedicated Hot SpareUse the following omconfig command syntax to assign one or more physical disks to a vi

Strona 126

omconfig storage Commands 211omconfig Delete Virtual Disk Use the following omconfig command syntax to delete a virtual disk. CAUTION: Deleting a vi

Strona 127 - NOTE: extipmiusergroup

212 omconfig storage Commandswhere id is the controller ID and virtual disk ID as reported by the omreport command. To obtain these values, type omrep

Strona 128

omconfig storage Commands 213Example for SAS Controllers In this example, type: omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5

Strona 129

214 omconfig storage Commandsomconfig Clear Virtual Disk Bad BlocksUse the following omconfig command syntax to clear virtual disk bad blocks.Complete

Strona 130

omconfig storage Commands 215See the Dell OpenManage Online Help for more information about the controller-specific diskcache, read, write, and cache

Strona 131

216 omconfig storage CommandsExample for SCSI, SATA, and ATA Controllers To replace the member disk described in this example, type: omconfig storage

Strona 132

omconfig storage Commands 217omconfig Controller Commands The following sections provide the omconfig command syntax required to execute controller ta

Strona 133

218 omconfig storage Commandsaction=setchangecontrollerproperties controller=<id> [bgirate=<rate>][reconstructrate=<rate>][checkcons

Strona 134

omconfig storage Commands 219action=importforeignconfig controller=idaction=importrecoverforeignconfig controller=idaction=clearforeignconfig controll

Strona 135 - Command Result Description

22 IntroductionScripting and Comparing With the CLIThe Server Administrator CLI allows administrators to write batch programs or scripts to be execute

Strona 136

220 omconfig storage Commandsomconfig Rescan Controller Use the following omconfig command syntax to rescan a controller. See Dell OpenManage Online H

Strona 137 - Defining Alert Actions

omconfig storage Commands 221omconfig Disable Controller Alarm Use the following omconfig command syntax to disable the controller alarm. See the Dell

Strona 138 - Available Alert Actions

222 omconfig storage Commandsomconfig Test Controller Alarm Use the following omconfig command syntax to test the functionality of the controller alar

Strona 139

omconfig storage Commands 223In some circumstances, you may receive a warning message if this command deletes the system or boot partition. You can ov

Strona 140

224 omconfig storage CommandsStorage Management supplies default values for any of the other parameters that you do not specify. For creating an encry

Strona 141 - Example Fan Probe Actions

omconfig storage Commands 225controller=id Parameter (Required) Specify the controller ID as reported by the omreport storage controller command. For

Strona 142 - Commands for Clearing Logs

226 omconfig storage Commandssize=<number | max | min> Parameter (Required) Table 8-6 indicates how to specify the size=<number | max | min&g

Strona 143 - Action Description

omconfig storage Commands 227[cachepolicy=<d | c>] Parameter (Optional) Different controllers support different cache policies. Table 8-7 indica

Strona 144

228 omconfig storage Commands[writepolicy=<wb| wt| wc| nwc>] Parameter (Optional) Different controllers support different write policies. Table

Strona 145

omconfig storage Commands 229Example Syntax For example, you may want to create a RAID-5 virtual disk on a PERC 3/QC controller. See the Dell OpenMana

Strona 146

Introduction 23Command Syntax OverviewCommands vary in complexity. The simplest command has only command level 1. The omhelp command is a simple comma

Strona 147

230 omconfig storage CommandsExample Syntax To set the rebuild rate to 50 on controller 1, type: omconfig storage controller action=setrebuildrate con

Strona 148 - Severity

omconfig storage Commands 231omconfig Discard Preserved Cache Use the following omconfig storage command syntax to discard the preserved cache on the

Strona 149

232 omconfig storage Commandsomconfig Change Encryption Key Use the following omconfig storage command syntax to change the encryption key for the con

Strona 150 - Example Recovery Commands

omconfig storage Commands 233omconfig Set Background Initialization RateUse the following omconfig command syntax to set the background initialization

Strona 151 - Example Shutdown Commands

234 omconfig storage Commandsomconfig Set Check Consistency RateUse the following omconfig command syntax to set the check consistency rate. Complete

Strona 152 - Description

omconfig storage Commands 235Depending on the controller, the log file name is afa_<mmdd>.log or lsi_<mmdd>.log where <mmdd> is the

Strona 153

236 omconfig storage CommandsExample SyntaxTo unlock the encrypted DKM configuration drives on controller 1, type:omconfig storage controller action=u

Strona 154

omconfig storage Commands 237Example Syntax To import and recover foreign configurations on controller 1, type: omconfig storage controller action=imp

Strona 155 - Ownership Values

238 omconfig storage CommandsExample SyntaxTo spin down drives that are not configured or hot spares that are unattended for 30 minutes, type:omconfig

Strona 156

omconfig storage Commands 239Example SyntaxTo start the patrol read task on controller 1, type:omconfig storage controller action=startpatrolread cont

Strona 157

24 IntroductionIn each section, command syntax and other information about commands is formatted with any of the following fields that apply:command l

Strona 158

240 omconfig storage CommandsComplete Syntaxomconfig storage controller action=createcachecade controller=id pdisk=<PDISKID> [name=<string>

Strona 159

omconfig storage Commands 241omconfig Switch to LKM ControllerUse the following omconfig storage command syntax to change the encryption key from DKM

Strona 160

242 omconfig storage Commandsomconfig Switch to DKM ControllerUse the following omconfig storage command syntax to change the encryption key from LKM

Strona 161 - Adding Lease Information

omconfig storage Commands 243omconfig Rekey DKM ControllerUse the following omconfig storage command syntax to re-key the encryption key in DKM mode f

Strona 162

244 omconfig storage Commandsomconfig Enclosure Commands The following sections provide the omconfig command syntax required to execute enclosure task

Strona 163

omconfig storage Commands 245omconfig Enable Enclosure Alarm Use the following omconfig command syntax to enable the enclosure alarm: Complete Syntax

Strona 164 - Adding Outsource Information

246 omconfig storage CommandsExample for SCSI, SATA, and ATA Controllers To disable the alarm on the enclosure attached to connector 2 on controller 1

Strona 165 - Adding Owner Information

omconfig storage Commands 247omconfig Set Enclosure Asset Name Use the following omconfig command syntax to specify the asset name for an enclosure. C

Strona 166

248 omconfig storage CommandsComplete Syntax omconfig storage enclosure action=settempprobes controller=id enclosure=<ENCLOSUREID> index=id minw

Strona 167

omconfig storage Commands 249Example for SCSI, SATA, and ATA Controllers In this example, temperature probe 3 resides in the enclosure attached to con

Strona 168 - Adding Support Information

Using the omhelp Command 252Using the omhelp CommandThe omhelp command and its equivalent, <command> -?, accesses the detailed help text interfa

Strona 169

250 omconfig storage Commandsomconfig Reset All Temperature Probe ThresholdsUse the following omconfig command syntax to reset the minimum and maximum

Strona 170 - Adding System Information

omconfig storage Commands 251Example for SCSI, SATA, and ATA Controllers To blink the LEDs for the enclosure attached to connector 2 on controller 1,

Strona 171 - Adding Warranty Information

252 omconfig storage CommandsExample SyntaxTo start the learn cycle on controller 1, type:omconfig storage battery action=startlearn controller=1 batt

Strona 172

omconfig storage Commands 253omconfig Global Enable Smart Thermal ShutdownBy default, the operating system and server shut down when the PV220S and PV

Strona 173 - Using the Storage Management

254 omconfig storage Commands NOTE: You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enab

Strona 174 - Command Elements

omconfig storage Commands 255Example SyntaxThe omconfig command syntax for rescanning all controllers on the system does not require that you specify

Strona 175 - Syntax Description

256 omconfig storage Commandsomconfig Connector Commands The following sections provide the omconfig command syntax required to execute connector task

Strona 176

omconfig storage Commands 257omconfig Cachecade Commands The following sections provide the omconfig command syntax required to execute cachecade task

Strona 177

258 omconfig storage Commandsomconfig Unblink Cachecade Use the following omconfig command syntax to unblink the physical disks included in a cachecad

Strona 178 - Replacing

omconfig storage Commands 259Example Syntax To delete cachecade 4 on controller 1, type: omconfig storage cachecade action=deletecachecade controller=

Strona 179 - NOTE: The cachecade

26 Using the omhelp Command• recovery• shutdown• thrmshutdown• webserverFigure 2-1 shows the levels of help for a command.Figure 2-1. Different Levels

Strona 180 - 180 omreport storage Commands

260 omconfig storage Commandsomconfig Rename Cachecade Use the following omconfig command syntax to rename a cachecade. Complete Syntax omconfig stora

Strona 181 - NOTE: This command is not

Working With CLI Command 2619Working With CLI Command ResultsServer Administrator Command Line Interface (CLI) users can use the command output in var

Strona 182 - 182 omreport storage Commands

262 Working With CLI CommandLinux Enterprise Server terminal. To display command output with control over scrolling, type the CLI command and append t

Strona 183 - Required Command Levels

Working With CLI Command 263Four hours later, you repeat the command. You have no interest in the 11:00 A.M. snapshot as written to fans.txt. You type

Strona 184 - NOTE: For SCSI controllers

264 Working With CLI CommandFans.txt now reads as follows:You can use a text editor to insert the time that each block of data was captured. In compar

Strona 185 - 2, 3) and name=value pair

Working With CLI Command 265The Syntax for the formatting option is:<command> -fmt <format option>For example, type:omreport system summar

Strona 186 - 186 omreport storage Commands

266 Working With CLI Command--------------Network Data--------------Network Interface Card 0 DataIP Address: 143.166.152.108Subnet Mask: 255.255.255.0

Strona 187 - Report Commands

Working With CLI Command 267omreport system summary -fmt ssvoromreport servermodule summary -fmt ssvThe example output displays as follows:-----------

Strona 188 - Optional name=

268 Working With CLI Command

Strona 189

Index 269IndexSymbols-?omconfig, 89omconfig chassis, 92omreport, 37request for help, 25Aaboutomconfig, 90acquisitioninformation, 155optional parameter

Strona 190 - 190 omreport storage Commands

Using the omhelp Command 27For one info value, specify one or more optional parameter(s). Table 2-1 displays the optional parameters for info=acquisit

Strona 191

270 Indexomconfig chassis, 92omreport chassis, 41blinkomconfig, 250blink physical diskomconfig, 193bmcomconfig chassis, 117omreport chassis, 62Ccache

Strona 192 - 192 omconfig storage Commands

Index 271command levels 1,2, and 3omconfig, 85command levels 1,2,3omreport, 31command syntax overview, 23commands for clearing logs, 142commands for v

Strona 193 - Example for SAS Controllers

272 Indexdelay battery learn cycleomconfig, 252delete virtual diskomconfig, 211, 258-260delimitersdata fields, 132depreciation informationabout, 158ad

Strona 194

Index 273formatting CLI command output, 264frontpanelomconfig chassis, 108omreport chassis, 47Gglobalinfoomconfig storage, 253omreport storage, 188Hhe

Strona 195

274 IndexNname=value pairsomconfig chassis biossetup, 93omconfig chassis bmc, 118nicsomreport chassis, 52NMI button, 48Oomconfgcancel initialize virtu

Strona 196

Index 275reset temperature probe thresholds, 248-250resume check consistency, 205secure virtual disk, 213set controller rebuild rate, 229set enclosure

Strona 197

276 Indexomconfig enable LKM controller, 240omconfig enclosure commands, 244, 257omconfig global commands, 252omconfig offline physical disk, 196omcon

Strona 198

Index 277info=maintenance, 163info=outsource, 165info=owner, 166info=service, 167info=support, 169info=system, 170info=warranty, 172omconfig system ev

Strona 199

278 Indexbase I/O address, 54connector type, 54external name, 53IRQ level, 54maximum speed, 54port type, 53omreport chassis processorscache properties

Strona 200

Index 279Pparameters for fan warning thresholds, 107pause check consistencyomconfig, 205pdisk, 192omconfig storage, 173-174omconfig virtual disk, 223-

Strona 201 - Example Syntax

28 Using the omhelp Command

Strona 202

280 Indexomconfig, 205Sscripting, 22scripting with the CLI, 22secure virtual disk, 213service contract information, 167adding, 167set enclosure asset

Strona 203 - Optional name=value pairs

Index 281thrmshutdownomconfig system, 152omreport system, 80Uunblink physical diskomconfig, 193unlock DKM foreign configurationomconfig, 235user acces

Strona 204

Index 282

Strona 205

omreport: Viewing System Status 293omreport: Viewing System Status Using the Instrumentation ServiceThe omreport command allows you to see detailed in

Strona 206

Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 15Overview . . . . . . . . . . . . . . . . . . . . . . . . 15What&a

Strona 207

30 omreport: Viewing System StatusConventions for Parameter TablesWhen listing the parameters that a command can take, the parameters are listed in al

Strona 208

omreport: Viewing System Status 31Table 3-2. Command Level 1, Level 2, and Level 3 for omreportCommand Level 1Command Level 2 Command Level 3User Pri

Strona 209

32 omreport: Viewing System Statusfans U, P, A Shows the status and thresholds for system fans.firmware U, P, A Shows the name and version of the firm

Strona 210

omreport: Viewing System Status 33leds U, P, A Shows the properties you have set for light-emitting diodes to flash under various alert conditions.mem

Strona 211

34 omreport: Viewing System Statusremoteaccess U, P, A Shows general information on remote access.slots U, P, A Shows properties of your system’s expa

Strona 212 - Example Syntax to reconfigure

omreport: Viewing System Status 35alertlog U, P, A Allows the administrator to display the alert log.assetinfo U, P, A Shows the cost of ownership inf

Strona 213

36 omreport: Viewing System Statusrecovery P, A Shows how your system is configured to respond to a hung operating system.shutdown P, A Shows how the

Strona 214

omreport: Viewing System Status 37Help With the omreport CommandUse the omreport -? command to get a list of the available commands for omreport.Use o

Strona 215

38 omreport: Viewing System Statusomreport aboutUse the omreport about command to learn the product name and version number of the systems management

Strona 216

omreport: Viewing System Status 39Server Administrator includes a number of services, each of which has a version number of its own. The Contains fiel

Strona 217

4 Contentsomreport modularenclosure . . . . . . . . . . . . . . . 37omreport about . . . . . . . . . . . . . . . . . . . . . 38omreport chassis/om

Strona 218 - 218 omconfig storage Commands

40 omreport: Viewing System StatusServer Administrator displays a general status for your main system chassis/main system components.omreport chassis

Strona 219

omreport: Viewing System Status 41Server Administrator reports values for the Redundancy Status and Redundancy Mode fields.omreport chassis batteries/

Strona 220

42 omreport: Viewing System StatusTable 3-3 dis plays the availa ble BIOS setup parameters: NOTE: All the BIOS Setup parameters are not displayed. On

Strona 221

omreport: Viewing System Status 43NIC 1 Displays whether the first NIC is enabled (with or without PXE/iSCSI) or disabled during system boot.NIC 2 Di

Strona 222

44 omreport: Viewing System StatusIDE Primary Drive 0 Displays whether the device is automatically detected and enabled or if the device is disabled.I

Strona 223 - For SAS Controllers

omreport: Viewing System Status 45To view all available boot devices, alias names, and boot order sequences, type:omreport chassis biossetup attribute

Strona 224

46 omreport: Viewing System StatusDepending on your configuration of your system, you may notice the following output:Removable Flash Media Informatio

Strona 225

omreport: Viewing System Status 47omreport chassis fans/omreport mainsystem fansUse the omreport chassis fans or omreport mainsystem fans command to v

Strona 226 - Parameter Specification

48 omreport: Viewing System StatusIf the NMI button is present on your system, you can see whether the NMI button is enabled or not. The NMI button ca

Strona 227

omreport: Viewing System Status 49Depending on your system’s configuration, you may notice the following output:omreport chassis info/omreport mainsys

Strona 228 - RAID 10)

Contents 5omreport chassis nics/omreport mainsystem nics. . . . . . . . . . . . . 52omreport chassis ports/omreport mainsystem ports . . . . . . . .

Strona 229

50 omreport: Viewing System Statusomreport chassis intrusionUse the omreport chassis intrusion command to find out whether the cover of your system is

Strona 230

omreport: Viewing System Status 51The following is an example output:omreport chassis memory/omreport mainsystem memoryUse omreport chassis memory or

Strona 231

52 omreport: Viewing System StatusIf your system supports redundant memory, the redundancy output may resemble the following:omreport chassis nics/omr

Strona 232

omreport: Viewing System Status 53If you specify the index, Server Administrator displays properties for a specific NIC and the values for the followi

Strona 233

54 omreport: Viewing System StatusBase I/O Address is the starting I/O address expressed in hexadecimal.IRQ Level is a hardware interrupt on a system.

Strona 234

omreport: Viewing System Status 55Capabilities and Cache Properties of a Specific ProcessorTo view the cache properties of a processor on a given conn

Strona 235

56 omreport: Viewing System Status NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features may not be

Strona 236

omreport: Viewing System Status 57Associativity refers to the way in which main memory content is stored on the cache. • A fully associative cache all

Strona 237

58 omreport: Viewing System StatusCustom attributes are:CPU Power and Performance Management, Memory Power and Performance Management, and Fan Power a

Strona 238

omreport: Viewing System Status 59For each power monitoring profile in the system, values display for the following fields:• Power Consumption Status

Strona 239

6 Contentsomreport system recovery/omreport servermodule recovery . . . . . . . . . 73omreport system shutdown/omreport servermodule shutdown. . . .

Strona 240

60 omreport: Viewing System StatusPower Consumption InformationPower ConsumptionIndexStatusProbe NameReadingWarning ThresholdFailure Threshold: 2: Ok:

Strona 241

omreport: Viewing System Status 61omreport chassis pwrsupplies/omreport mainsystem pwrsuppliesUse the omreport chassis pwrsupplies or omreport mainsys

Strona 242

62 omreport: Viewing System StatusFor each power supply profile in the system, values display for the following fields: • Status•Location•Type• Rated

Strona 243

omreport: Viewing System Status 63omreport chassis slots/omreport mainsystem slotsUse the omreport chassis slots or omreport mainsystem slots command

Strona 244 - 244 omconfig storage Commands

64 omreport: Viewing System StatusAdapter refers to the name and/or type of the card that fits into the slot, for example, a storage array controller,

Strona 245

omreport: Viewing System Status 65omreport system Commands/omreport servermodule CommandsUse the omreport system or omreport servermodule commands to

Strona 246

66 omreport: Viewing System StatusCommands for Viewing LogsYou can use the omreport system or omreport servermodule command to view logs: the alert lo

Strona 247

omreport: Viewing System Status 67omreport system alertaction/omreport servermodule alertactionUse the omreport system alertaction or omreport serverm

Strona 248

68 omreport: Viewing System Status• Power Supply Warning• Power Supply Failure• Degraded Redundancy• Lost Redundancy• Temperature Warning• Temperature

Strona 249 - ° Celsius, type:

omreport: Viewing System Status 69• Removable Flash Media Present• Removable Flash Media Removed• Removable Flash Media Failure NOTE: Storage Control

Strona 250

Contents 7omconfig chassis memorymode/omconfig mainsystem memorymode. . . . . . . . 112omconfig chassis pwrmanagement/omconfig mainsystem pwrmanageme

Strona 251

70 omreport: Viewing System Status---------------Power Supplies----------------SettingsEnable: Informational, Warning and CriticalDisable: None-------

Strona 252

omreport: Viewing System Status 71Example Command for an Event TypeTy p e :omreport system events type=fansoromreport servermodule events type=fansThe

Strona 253

72 omreport: Viewing System Statusomreport system pedestinations/omreport servermodule pedestinationsUse the omreport system pedestinations or omrepor

Strona 254

omreport: Viewing System Status 73omreport system platformevents/omreport servermodule platformeventsUse the omreport system platformevents or omrepor

Strona 255

74 omreport: Viewing System Statusomreport system shutdown/omreport servermodule shutdownUse the omreport system shutdown or omreport servermodule shu

Strona 256

omreport: Viewing System Status 75System Summary------------------Software Profile------------------System ManagementName : Dell OpenManage Server Adm

Strona 257

76 omreport: Viewing System StatusSystem--------------Host Name : svctag-dxxxxsSystem Location: Please set the valueModel : PowerEdge 1955Life Cycle C

Strona 258

omreport: Viewing System Status 77Voltage : 1400 mVProcessor 2Processor Brand: Intel(R) Xeon(R) CPUProcessor Version: Model 15 Stepping 6Voltage : 1

Strona 259

78 omreport: Viewing System StatusThe system summary hardware information includes data values for installed components of the following types present

Strona 260

omreport: Viewing System Status 79ProcessorThe following are listed for each processor in the system:• Processor Brand• Processor Family• Processor Ve

Strona 261 - Working With CLI Command 261

8 Contentsomconfig system thrmshutdown/omconfig servermodule thrmshutdown . . . . . . 1525 omconfig system or servermodule assetinfo: Editing Cost of

Strona 262 - Working With CLI Command

80 omreport: Viewing System StatusBIOS • Manufacturer •BIOS Version• Release DateFirmware •Name •VersionNetwork Data The following details are listed

Strona 263 - Working With CLI Command 263

omreport: Viewing System Status 81If the system is configured to shutdown when a temperature probe detects a warning or failure event, one of the foll

Strona 264

82 omreport: Viewing System Status---------------Software---------------Name : Microsoft Windows Server 2003, Enterprise EditionVersion : 5.2

Strona 265 - List (lst)

omconfig: Managing Components 834omconfig: Managing Components Using the Instrumentation ServiceThe omconfig command allows you to provide values that

Strona 266 - Table (tbl)

84 omconfig: Managing ComponentsConventions for Parameter TablesWhen listing the parameters that a command can take, the parameters are listed in alph

Strona 267 - Custom Delimited Format (cdv)

omconfig: Managing Components 85Table 4-2. omconfig Command Level 1, Level 2, and Level 3Command Level 1Command Level 2Command Level 3 User Privilege

Strona 268 - 268 Working With CLI Command

86 omconfig: Managing Componentsalertaction P, A Determines in advance the actions to be taken for warning or failure events on intrusion, fans, tempe

Strona 269 - Index 269

omconfig: Managing Components 87shutdown A Allows the administrator to select from several options when shutting down the system.thrmshutdown A Sets t

Strona 270

88 omconfig: Managing Componentsleds P, A Specifies when to flash a chassis fault LED or chassis identification LED, and allows you to clear the LED f

Strona 271 - Index 271

omconfig: Managing Components 89Help With the omconfig CommandUse the omconfig -? command to get a list of the available commands for omconfig.Use omc

Strona 272

Contents 9Adding Service Contract Information . . . . . . . . . . 167Example Command for Adding Service Information . . . . . . . . . . . . 167Addin

Strona 273 - Index 273

90 omconfig: Managing ComponentsTo scroll command output one screen at a time, type:omconfig system alertaction -? | morewhere | more allows you to pr

Strona 274

omconfig: Managing Components 91Server Administrator includes a number of services, each of which has a version number of its own. The Contains field

Strona 275 - Index 275

92 omconfig: Managing Componentsomconfig chassis/omconfig mainsystemUse the omconfig chassis or omconfig mainsystem commands to default or to set valu

Strona 276

omconfig: Managing Components 93Table 4-3 shows the name=value pairs you can use with this command.Table 4-3. BIOS Setup Settingsname=value pair 1attr

Strona 277 - Index 277

94 omconfig: Managing Componentsattribute=bootordersequence=aliasname1, aliasname2,... aliasnameNConfigures the boot sequence according to the set a

Strona 278

omconfig: Managing Components 95attribute=conredirectsetting=enabled | disabledenabled: Redirects the BIOS screen over Serial Port 1. Keyboard and tex

Strona 279 - Index 279

96 omconfig: Managing Componentsattribute=cpuxdsupportsetting=enabled | disabledenabled: Enables Execute Disable (XD) support on system.disabled: Disa

Strona 280

omconfig: Managing Components 97attribute=dualnic setting=off | on | pxeboth | nic1pxe |nic2pxe | isciboth | nic1isci | nic2isci | nic1pxenic2isci | n

Strona 281 - Index 281

98 omconfig: Managing Componentsattribute=embvideoctrlsetting=enabled | disabledenabled: Enables the embedded video controller to be the primary video

Strona 282 - Index 282

omconfig: Managing Components 99attribute=ide setting=on | offforce=trueon: Enables this device.off: Disables this device.force=true: Verification of

Komentarze do niniejszej Instrukcji

Brak uwag