Dell PowerEdge M520 (for PE VRTX) Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Dell PowerEdge M520 (for PE VRTX). Dell PowerEdge M520 (for PE VRTX) User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Owner's Manual

Dell PowerEdge M520 Systems (For Dell PowerEdge VRTX Enclosure)Owner's ManualRegulatory Model: HHBRegulatory Type: HHB004

Strona 2 - Notes, Cautions, and Warnings

• The Getting Started Guide for the VRTX enclosure provides an overview of the VRTX enclosure and the server modules, setting up your system, and tech

Strona 3 - Contents

Error Code Message InformationAction Cycle input power, update component drivers, if device is removable, reinstall the device.PCI1360Message A bus fa

Strona 4

Error Code Message InformationDetails Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and does not support FlexAddress.Action Update B

Strona 5

Error Code Message InformationAction Cycle input power, update component drivers, remove and reinstall the device at the next scheduled service time.

Strona 6

Error Code Message InformationDetails The controller detected that the drive was removed. Action Verify drive installation. Re-seat the failed drive.

Strona 7 - About Your System

Error Code Message InformationPST0132Message CMOS failed.LCD Message CMOS failed. Power cycle system.Details System BIOS detected a failure with CMOS

Strona 8 - Hard-Drive Indicator Patterns

Error Code Message InformationDetails System BIOS detected a parity error during post.Action Remove and reapply input power. If the issue persists, s

Strona 9

Error Code Message InformationPST0143Message Intel Trusted Execution Technology (TXT) fatal error.LCD Message Intel Trusted Execution Technology (TXT)

Strona 10

Error Code Message InformationLCD Message Incorrect memory configuration. Review User Guide.Details System BIOS detected an invalid memory population.

Strona 11 - Choosing The System Boot Mode

Error Code Message InformationPSU0004Message The power input for power supply <number> is outside of the allowable range.LCD Message Power input

Strona 12 - System Setup Options

Error Code Message InformationLCD Message PSU <number> is absent. Check PSU.Details The supply has been removed or has failed. Action1. Remove

Strona 13 - System Information Screen

2Using The System Setup And Boot ManagerSystem Setup enables you to manage your system hardware and specify BIOS-level options.NOTE: You can access Sy

Strona 14 - Processor Settings Screen

Error Code Message InformationDetails The current power operational mode is non-redundant because of a power supply exception, a power supply inventor

Strona 15 - SATA Settings Screen

Error Code Message InformationAction If unintended, review system configuration changes and power policy.PWR1006Message The system halted because syst

Strona 16 - Integrated Devices Screen

Error Code Message InformationRFM1006Message Removable Flash Media <name> is offline.Details At boot, the Card Identification (CID) signature of

Strona 17 - Serial Communications Screen

Error Code Message InformationRFM1024Message Removable Flash Media is offline.Details At boot, the Card Identification (CID) signature of the card is

Strona 18

Error Code Message InformationRFM1205Message Internal Dual SD Module is not redundant. Insufficient resources to maintain normal operations.LCD Messag

Strona 19 - Miscellaneous Settings

Error Code Message InformationSEC0001Message The drive bay is open.Details The drive bay is open. A drive may be added or removed. System performance

Strona 20

Error Code Message InformationSEC0033Message The chassis is open while the power is off.LCD Message Intrusion detected. Check chassis cover.Details Th

Strona 21

Error Code Message InformationAction Check system hardware inventory and software configuration.SEC0600Message A secure mode violation detected.Detail

Strona 22

Error Code Message InformationAction If unintended, re-enable logging.SEL0006Message All event logging is disabled.Details This message is displayed w

Strona 23 - UEFI Boot Menu

Error Code Message Informationa platform event (such as power down, cycle, interrupt, and send alert).Action Review platform event configuration.SEL12

Strona 24 - Embedded System Management

• UEFI boot mode is an enhanced 64-bit boot interface based on Unified Extensible Firmware Interface (UEFI) specifications that overlays the system BI

Strona 25 - Recommended Tools

Error Code Message InformationDetails An action or failure has taken place that breaks CMC redundancy.Action Check the CMC network cables and network

Strona 26 - 1. I/O connector cover

Error Code Message InformationSWC4004Message A firmware or software incompatibility detected between iDRAC in slot <number> and CMC.Details Flex

Strona 27 - Opening The Server Module

Error Code Message InformationLCD Message System board <name> temperature is outside of range.Details Ambient air temperature is too warm or one

Strona 28 - Inside The System

Error Code Message InformationDetails Ambient air temperature is too warm or one or more fans may have failed.Action The system board <name> tem

Strona 29 - Cooling Shroud

Error Code Message InformationAction Check the system operating environment and review event log for fan failures.TMP0115Message The <name> temp

Strona 30 - System Memory

Error Code Message InformationLCD Message System inlet <name> temperature is outside of range. Check Fans.Details Ambient air temperature is too

Strona 31

Error Code Message InformationTMP0130Message The control panel temperature is less than the lower warning threshold.LCD Message Control panel temperat

Strona 32 - Mode-Specific Guidelines

Error Code Message InformationDetails System hardware detected an over voltage or under voltage condition.If multiple voltage exceptions occur consecu

Strona 33 - Sample Memory Configurations

Error Code Message InformationDetails System hardware detected an over voltage or under voltage condition.If multiple voltage exceptions occur consecu

Strona 34

Error Code Message InformationDetails System hardware detected an over voltage or under voltage condition.If multiple voltage exceptions occur consecu

Strona 35 - Removing Memory Modules

System Setup Main ScreenNOTE: Press <Alt><F> to reset the BIOS or UEFI settings to their default settings.Menu Item DescriptionSystem BIOS

Strona 36 - Installing Memory Modules

Error Code Message InformationDetails System hardware detected an over voltage or under voltage condition.If multiple voltage exceptions occur consecu

Strona 37 - PCIe Mezzanine Cards

Error Code Message InformationDetails System hardware detected an over voltage or under voltage condition.If multiple voltage exceptions occur consecu

Strona 38

Error Code Message InformationDetails System hardware detected an over voltage or under voltage condition.If multiple voltage exceptions occur consecu

Strona 39 - Management Riser Card

Error Code Message InformationDetails System hardware detected an over voltage or under voltage condition.If multiple voltage exceptions occur consecu

Strona 40 - Internal USB Key

Error Code Message InformationIf multiple voltage exceptions occur consecutively the system may power down in fail-safe mode.Action1. Review system lo

Strona 41 - SD vFlash Card

Error Code Message InformationIf multiple voltage exceptions occur consecutively the system may power down in fail-safe mode.Action1. Review system lo

Strona 42 - Processors

Error Code Message InformationIf multiple voltage exceptions occur consecutively the system may power down in fail-safe mode.Action1. Review system lo

Strona 43

Error Code Message Information2. Re-seat the PCIe mezzanine card.3. If the issue persists, see Getting Help.VLT0232Message The PCIe mezzanine card <

Strona 44 - Installing A Processor

Warning MessagesA warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before

Strona 45 - Hard Drives/SSDs

9Getting HelpContacting DellNOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing

Strona 46 - Removing A Hard Drive/SSD

Menu Item DescriptionSystem Service Tag Displays the system Service Tag.System Manufacturer Displays the name of system manufacturer.System Manufactur

Strona 47 - Configuring The Boot Drive

Menu Item DescriptionAlternate RTID (Requestor Transaction ID) SettingAllows you to allocate more RTIDs to the remote socket increasing cache performa

Strona 48 - Hard-Drive/SSD Backplane

Boot Settings ScreenMenu Item DescriptionBoot Mode Allows you to set the boot mode of the system.CAUTION: Switching the boot mode may prevent the syst

Strona 49

Menu Item DescriptionNOTE: This option is displayed only if IDSDM is installed on the system board.Integrated Network Card 1Allows you to enable or di

Strona 50 - System Board

Menu Item DescriptionRedirection After BootAllows you to enable or disable to the BIOS console redirection when the operating system is loaded. By def

Strona 51 - Installing The System Board

System Security ScreenMenu Item DescriptionIntel AES-NI The Intel AES-In option improves the speed of applications by performing encryption and decryp

Strona 52 - NVRAM Backup Battery

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Strona 53 - Storage Controller Card

Menu Item DescriptionAsset Tag Displays the asset tag and allows you to modify it for security and tracking purposes.Keyboard NumLock Allows you to se

Strona 54

4. In the System Security screen, verify that Password Status is Unlocked.5. Select System Password , enter your system password, and press <Enter&

Strona 55 - Troubleshooting Your System

4. In the System Security screen, verify that Password Status is Unlocked.5. Select System Password, alter or delete the existing system password and

Strona 56 - Troubleshooting USB Devices

Using The Boot Manager Navigation KeysKey DescriptionUp arrow Moves to the previous field.Down arrow Moves to the next field.<Enter> Allows you

Strona 57 - Troubleshooting Processors

Menu Item DescriptionAdd Boot Option Adds a new boot option.Delete Boot Option Deletes an existing boot option.Embedded System ManagementThe Dell Life

Strona 58

3Installing Server Module ComponentsRecommended ToolsYou may need the following items to perform the procedures in this section:• #1 and #2 Phillips s

Strona 59 - Using System Diagnostics

Figure 4. Removing and Installing the I/O Connector Cover1. I/O connector coverFigure 5. Removing and Installing a Server Module26

Strona 60 - System Diagnostic Controls

1. release button2. PCIe label on server moduleNOTE: This label indicates that the server module is configured specifically for the VRTX enclosure.3.

Strona 61 - Jumpers And Connectors

Figure 6. Opening and Closing the server module1. I/O connector cover2. server module cover3. release button4. cover alignment pins and notchesClosing

Strona 62 - System Board Connectors

Figure 7. Inside the Server Module1. management riser card2. PCIe Mezzanine card 1 - Fabric C3. PCIe Mezzanine card 2 - Fabric B4. cooling shroud5. pr

Strona 63

ContentsNotes, Cautions, and Warnings... 21 About Your

Strona 64

Figure 8. Removing and Installing a Cooling Shroud1. cooling shroud2. tabs (5)3. slots on the chassis (5)Installing The Cooling ShroudCAUTION: Many re

Strona 65 - Technical Specifications

• DIMM operating voltage• system profile selected (for example, Performance Optimized, Custom, or Dense Configuration Optimized)• maximum supported DI

Strona 66

Processor 1 channel 1: memory sockets A1 and A4channel 2: memory sockets A2 and A5channel 3: memory sockets A3 and A6Processor 2 channel 1: memory soc

Strona 67 - Environmental

Advanced ECC (Lockstep)Advanced ECC mode extends SDDC from x4 DRAM based DIMMs to both x4 and x8 DRAMs. This protects against single DRAM chip failure

Strona 68

Table 1. Memory Configurations — Single ProcessorSystem Capacity (in GB)DIMM Size (in GB)Number of DIMMsOrganization and SpeedDIMM Slot Population2 2

Strona 69 - System Messages

System Capacity (in GB)DIMM Size (in GB)Number of DIMMsOrganization and SpeedDIMM Slot Population160 16 102R x4, 1333 MT/s2R x4, 1600 MT/sA1, A2, A3,

Strona 70

Figure 10. Installing and Removing a Memory Module or Memory Module Blank1. memory module or memory blank2. edge connector3. ejectors (2)4. socket5. a

Strona 71

NOTE: The memory module socket has an alignment key that allows you to install the memory module in the socket in only one way.7. Press down on the me

Strona 72

Figure 11. Removing and Installing a PCIe mezzanine Card1. PCIe mezzanine cards (2)2. Fabric B PCIe mezzanine card slot3. Fabric C PCIe mezzanine card

Strona 73

8. Close the server module.9. Install the server module in the enclosure.Management Riser CardThe management riser card provides two SD card slots and

Strona 74

iDRAC Settings Utility...

Strona 75

Figure 12. Replacing the SD Card1. SD card 12. SD card 23. management riser card4. USB connector5. SD card slot identification labelInternal USB KeyTh

Strona 76

6. Close the server module.7. Install the server module in the enclosure.8. Enter the System Setup and verify that the USB key is detected by the syst

Strona 77

1. SD vFlash card2. SD vFlash card slotProcessorsUse the following procedure when:• Installing an additional processor• Replacing a processorRemoving

Strona 78

Figure 15. Removing and Installing a Heat Sink1. retention sockets (4)2. heat sink3. retention screws (4)6. Use a clean, lint-free cloth to remove any

Strona 79

CAUTION: If you are permanently removing a processor, you must install a socket protective cap and a processor/DIMM blank in the vacant socket to ensu

Strona 80

CAUTION: Positioning the processor incorrectly can permanently damage the system board or the processor. Be careful not to bend the pins in the socket

Strona 81

Hard Drive/SSD Installation GuidelinesFor a single-drive configuration, a hard-drive blank must be installed in the other drive bay to maintain proper

Strona 82

Installing A Hard Drive/SSDCAUTION: When a replacement hot-swappable hard drive/SSD is installed and the server module is powered on, the drive automa

Strona 83

Figure 18. Removing and Installing a Hard Drive/SSD in a Hard-Drive/SSD Carrier1. hard drive/SSD2. screw holes (4)3. hard-drive/SSD carrier4. screws (

Strona 84

CAUTION: You must note the number of each hard drive/SSD and temporarily label them before removal so that you can replace them in the same locations.

Strona 85

Installing The System Board...

Strona 86

5. Close the server module.6. Install the server module in the enclosure.System BoardRemoving The System BoardCAUTION: Many repairs may only be done b

Strona 87

Figure 20. Removing and Installing the System Board1. I/O connector cover2. retention latch3. system board4. tabs on system chassis5. slots in system

Strona 88

7. Close the server module.8. Remove the plastic I/O connector covers from the back of the server module.9. Install the server module in the enclosure

Strona 89

Figure 21. Replacing the NVRAM Backup Battery1. positive side of battery2. negative side of battery connectorStorage Controller CardYour system includ

Strona 90

Figure 22. Removing and Installing a Storage Controller Card1. storage controller card2. screws (2)3. tabs (2)4. connectorInstalling The Storage Contr

Strona 91

4Troubleshooting Your SystemSafety First—For You and Your SystemCAUTION: Many repairs may only be done by a certified service technician. You should o

Strona 92

Troubleshooting Hard DrivesCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simpl

Strona 93

Troubleshooting An Internal SD CardCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting a

Strona 94

4. If there is a still a problem with the server module, remove and reinstall the server module in the enclosure.5. Turn on the server module.6. Run t

Strona 95

5Using System DiagnosticsIf you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The

Strona 97

Running The Embedded System DiagnosticsThe embedded system diagnostics program is run from the Dell Lifecycle Controller.CAUTION: Use the embedded sys

Strona 98

6Jumpers And ConnectorsSystem Board Jumper SettingsCAUTION: Many repairs may only be done by a certified service technician. You should only perform t

Strona 99

System Board ConnectorsFigure 23. System Board ConnectorsTable 4. System Board ConnectorsItem Connector Description1 PWRD_EN, NVRAM_CLR System configu

Strona 100

Item Connector Description13 USB1 USB connector14 BATTERY Connector for the 3.0 V coin cell batteryDisabling A Forgotten PasswordThe server modules so

Strona 102

7Technical SpecificationsProcessorProcessor type One or two Intel Xeon processor E5-2400 product familyMemoryArchitecture 1600 MT/s, 1333 MT/s, or 106

Strona 103

PCIe mezzanine CardsPCIe mezzanine card slots Two PCIe x8 Gen 2 slots supporting dual-port PCIe mezzanine cardsVideoVideo type Matrox G200 integrated

Strona 104

EnvironmentalFor temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 125 m above 950 m (1 °F per 228 ft).

Strona 106

8System MessagesLCD Status MessagesThe LCD messages consist of brief text messages that refer to events recorded in the System Event Log (SEL). For in

Strona 107

1About Your SystemIntroductionThis document provides information on the Dell PowerEdge M520 server module that is specifically configured for the Powe

Strona 108

Error Code Message InformationDetails System board <name> current is outside of the optimum range.Action1. Review system power policy.2. Check s

Strona 109

Error Code Message InformationLCD Message System board <name> current is outside of range.Details System board <name> current is outside o

Strona 110

Error Code Message InformationAMP0309Message Disk drive bay <name> current is greater than the upper critical threshold.LCD Message Disk drive b

Strona 111

Error Code Message InformationAMP0314Message System level current is greater than the upper warning threshold.Details System level current is outside

Strona 112

Error Code Message InformationAction1. Review system power policy.2. Check system logs for power related failures.3. Review system configuration chang

Strona 113

Error Code Message InformationASR0001Message The watchdog timer reset the system.Details The operating system or an application failed to communicate

Strona 114

Error Code Message InformationDetails The operating system or an application failed to communicate within the time-out period. The system was shutdown

Strona 115

Error Code Message InformationDetails The system board battery is either missing, bad, or unable to charge due to thermal issues.Action Check system f

Strona 116

Error Code Message InformationLCD Message Battery for disk drive bay <bay> is absent. Check battery.Details Verify the cable connection between

Strona 117

Error Code Message InformationLCD Message CPU <number> has a thermal trip. Check CPU heat sink.Details The processor temperature increased beyon

Strona 118

Front-Panel Features And IndicatorsFigure 2. Front-Panel Features and Indicators1. server module handle release button2. hard drives/SSDs (2) 3. statu

Strona 119

Error Code Message InformationAction1. Turn system off and remove input power for one minute. Reapply input power and turn system on. 2. Make sure th

Strona 120

Error Code Message InformationLCD Message CPU <number> temperature is outside of range. Check fans.Details System performance may be degraded.Ac

Strona 121

Error Code Message Informationdamage to the processor or other electronic components in side the system.Action1. Turn system off and remove input powe

Strona 122

Error Code Message Information4. If the issue persists, see Getting Help.CPU0701Message CPU <number> protocol error detected.LCD Message CPU <

Strona 123

Error Code Message InformationCPU0704Message CPU <number> machine check error detected.LCD Message CPU <number> machine check error detect

Strona 124

Error Code Message InformationAction1. Turn system off and remove input power for one minute.2. Reapply input power and turn system on.3. Ensure th

Strona 125

Error Code Message InformationDetails System performance may be degraded or the system may fail to operate.Action If removal was unintended, check pre

Strona 126

Error Code Message InformationAction If removal was unintended, check presence, then reinstall or reconnect.HWC2006Message The <name> is not ins

Strona 127

Error Code Message InformationHWC4000Message A hardware incompatibility detected between BMC/iDRAC firmware and CPU.LCD Message Incompatibility betwee

Strona 128

Error Code Message InformationAction Check chassis fabric type in CMC GUI and compare to the type of IOM or PCIe mezzanine card.HWC5004Message A link

Strona 129

NOTE: The server module must have a hard drive or a hard-drive blank installed in each hard-drive bay.Figure 3. Hard-Drive Indicators1. hard-drive act

Strona 130

Error Code Message InformationDetails The IOM module performance may be impacted.Action If the issue persists, see Getting Help.HWC6000Message The <

Strona 131

Error Code Message InformationAction Review System Log or front panel for additional information.HWC7008Message Server <number> health changed t

Strona 132

Error Code Message InformationMEM0002Message Parity memory errors detected on a memory device at location <location>.Details The memory is opera

Strona 133

Error Code Message InformationMEM0010Message Memory device at location <location> is over heating.LCD Message Memory device <location> is

Strona 134

Error Code Message InformationMEM1012Message Memory device at location <location> is in a degraded state.Details The memory may not be operation

Strona 135

Error Code Message InformationAction Review system logs for memory exceptions. reinstall memory at location <location>MEM1214Message Memory red

Strona 136

Error Code Message InformationAction Review system event log for platform events capable of shutting the system down.OSE0005Message Agent is not respo

Strona 137

Error Code Message InformationPCI1302Message A bus time-out was detected on a component at bus <bus>device<device>function <func>.De

Strona 138 - Warning Messages

Error Code Message InformationAction Cycle input power, update component drivers, if device is removable reinstall the device at the next scheduled se

Strona 139 - Getting Help

Error Code Message InformationPCI1344Message An I/O channel check error was detected.LCD Message An I/O channel check error was detected. Power cycle

Komentarze do niniejszej Instrukcji

Brak uwag