Cable Routing Procedures for Dell™ PowerEdge™ T610 Systems
Page 1
Contents
Introduction ............................................................................................................................................................... 2
Section 1: Cabling a Dell™ PowerEdge™ T610 With a Cable Management Arm (CMA) ............................................ 2
1.1 Connecting the CMA Cables to the System .................................................................................................. 2
1.2 Routing the Power Cables Through the Strain Reliefs ................................................................................. 3
1.3 Installation of the CMA ................................................................................................................................ 3
Section 2: Cabling a Dell™ PowerEdge™ T610 System Without a CMA ..................................................................... 5
2.1 Routing the Cables ....................................................................................................................................... 5
Section 3: Replacing a Power Supply on a PowerEdge™ T610 System With a CMA.................................................. 6
Table of Figures
Figure 1: System with Cables Installed .................................................................................................................. 2
Figure 2: Routing Power Cables Through the Strain Reliefs ............................................................................. 3
Figure 3: Routing the Cables Through the CMA ................................................................................................. 4
Figure 4: Right-Side Mounted CMA Installation .................................................................................................. 4
Figure 5: Left-Side Mounted CMA Installation ..................................................................................................... 5
Figure 6: Cable Routing Without a CMA ............................................................................................................... 5
Figure 7: Replacing the Power Supply ................................................................................................................... 6