Dell™PowerEdge™SC1425SystemsInstallationandTroubleshooting
Guide
Introduction
Indicators, Messages, and Codes
Finding Software Solutions
Running the System Diagnostics
Troubleshooting Your System
Installing System Components
Installing Drives
Getting Help
Jumpers, Switches, and Connectors
I/O Connectors
Service-Only Parts Replacement Procedures
Notes, Notices, and Cautions
Abbreviations and Acronyms
For a complete list of abbreviations and acronyms, see the Glossary in your User's Guide.
Information in this document is subject to change without notice.
©2004DellInc.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, PowerApp, PowerEdge, PowerConnect, PowerVault, DellNet, Axim, Latitude, and Dell
OpenManage are trademarks of Dell Inc.; Intel and Pentium are registered trademarks of Intel Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
Initial release: 15 Sept 2004
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Przeglądanie stron 0
1 2 3 4 5 6 ... 68 69

Podsumowanie treści

Strona 1 - Abbreviations and Acronyms

Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Introduction Indicators, Messages, and Codes Finding Software Solutions Runnin

Strona 2 - System Board Jumpers

Back to Contents Page  Service-Only Parts Replacement Procedures Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Recommen

Strona 3 - System Board Connectors

 3. Connect the control panel cables. See FigureC-1.  4. Close the system. See "Closing the System" in "Troubleshooting Your Sy

Strona 4 - Riser Board Connectors

 Installing the System Board Assembly   1. Unpack the new system board assembly.  2. Align the system board tray so that the tabs on the chas

Strona 5

 16. Close the system. See "Closing the System" in "Troubleshooting Your System." Back to Contents Page  NOTE: When installi

Strona 6 -  I/O Connectors

Back to Contents Page  Introduction Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Other Documents You May Need Your s

Strona 7 - Video Connector

Back to Contents Page  Indicators, Messages, and Codes Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide The system, applica

Strona 8 - Integrated NIC Connectors

Table 2-2.DiagnosticIndicatorCodes Hard-drive indicator The green hard-drive activity indicator flashes when the SATA hard drives are in use.

Strona 9 - Network Cable Requirements

Back-Panel Features and Indicators Figure2-2 shows the controls, indicators, and connectors located on the system's back panel. Figure 2-2. B

Strona 10 - Control Panel Assembly

System Messages System messages appear on the screen during system boot to notify you of a possible problem with the system. Table2-4 lists the sys

Strona 11 - System Board

Memory slots DIMM3_A and DIMM3_B must be empty if Dual Rank memory DIMMs are in slots DIMM2_A and DIMM2_B. Remove the memory modules in bank 3. See &

Strona 12

Back to Contents Page  Jumpers, Switches, and Connectors Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Jumpers—A Genera

Strona 13

System Beep Codes If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the pr

Strona 14 -  Introduction

Warning Messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, befo

Strona 15 - System Status Indicators

Alert Messages Systems management software generates alert messages for your system. Alert messages include information, status, warning, and failur

Strona 16

Back to Contents Page  Finding Software Solutions Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Before You Begin Tro

Strona 17 - NIC Indicators

Back to Contents Page  IRQ2 Interrupt controller 1 to enable IRQ8 through IRQ15 IRQ3 Available IRQ4 Serial port 1 (COM1 and COM3) IRQ5 Available IRQ6

Strona 18 - System Messages

Back to Contents Page  Running the System Diagnostics Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Using Dell Diagnost

Strona 19

1. Create a set of diagnostics diskettes from the Dell OpenManage Server Assistant CD. See "Using the Dell OpenManage Server Assistant" in y

Strona 20 - System Beep Codes

Back to Contents Page 

Strona 21 - Diagnostics Messages

Back to Contents Page  Troubleshooting Your System Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Safety First—For You a

Strona 22 - Alert Messages

This section provides troubleshooting procedures for external devices attached to the system, such as the monitor, keyboard, or mouse. Before you perf

Strona 23 - Before You Begin

Table A-1.SystemBoardJumperSettings System Board Connectors See FigureA-3 and TableA-2 for the location and description of the system boar

Strona 24

 2. Examine the mouse and its cable for signs of damage. If the mouse is not damaged, go to step 4. If the mouse is damaged, continue to the next s

Strona 25 - Using Dell Diagnostics

Problem l System message indicates a problem with a USB device. l Device connected to a USB port is not operating properly.  Action  1. Enter th

Strona 26

Figure 5-1. Inside the System The system board holds the system's control circuitry and other electronic components. The processor and memory

Strona 27 - Back to Contents Page

Figure 5-3. Installing and Removing the System Cover Closing the System  1. Ensure that you did not leave tools or parts inside the system. 

Strona 28 - Checking the Equipment

6. Let the system dry thoroughly for at least 24 hours.  7. Reinstall all of the components that you removed earlier in this procedure. See "

Strona 29 - Troubleshooting the Mouse

 1. Re-enter the time and date through the System Setup program. See "Using the System Setup Program" in your User's Guide.  2. Tu

Strona 30 - Problem

Action   1. Run the appropriate diagnostic test. See "Using Dell Diagnostics" in Running System Diagnostics."  2. Turn off the sy

Strona 31 - Inside the System

 10. Enter the System Setup program and check the system memory setting. See "Using the System Setup Program" in your User's Guide.

Strona 32 - Opening the System

l Damaged or improperly connected hard-drive cables.  Action   1. Run the appropriate online diagnostic test. See "Using Dell Diagnostics&q

Strona 33 - Closing the System

3. Ensure that the primary SCSI channel is enabled, and restart the system. See the documentation supplied with the controller for information about

Strona 34

Table A-2.SystemBoardConnectors Riser Board Connectors See FigureA-4 for the location and description of the riser card connectors. Figure

Strona 35

Troubleshooting the Processors  Problem l Error message indicates a processor problem. l A heat sink is not installed for each processor.  Act

Strona 36

22. Close the system. See "Closing the System."  23. Reconnect the system to the electrical outlet, and turn on the system and attached

Strona 37

Back to Contents Page  Installing System Components Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide This section describes

Strona 38

 1. Enter the System Setup program and record the option settings on the System Setup screens. See "Using the System Setup Program" in th

Strona 39

 5. Slide the fan modules toward the front of the system to remove them. Figure 6-3. Installing and Removing a Processor/Memory Fan Module  I

Strona 40

 Installing the Expansion Card Fan Module  1. With the fan power cable facing towards the rear of the system, align the fan module alignment hole

Strona 41

 Installing the Power Supply  1. Lower the power supply in the system and slide the new power supply backward until the power supply is fully seat

Strona 42 - System Battery

 3. Remove the filler bracket.  4. Insert the expansion card firmly into the expansion-card connector on the riser card until the card is fully

Strona 43

 1. Open the system. See "Opening the System" in "Troubleshooting Your System."  2. If applicable, remove the expansion card.

Strona 44

l If only one memory module is installed, it must be installed in socket DIMM1_A. l If two or more memory modules are installed, they must be insta

Strona 45 - Power Supply

 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  2. Open the system. See "Opening th

Strona 46 - Expansion Cards

Installing Memory Modules   1. Open the system. See "Opening the System" in Troubleshooting Your System."  2. Locate the memory m

Strona 47 - Riser Card

Processor It is possible to upgrade your processor(s) to take advantage of future options in speed and functionality. Each processor and its associa

Strona 48 - System Memory

the processor. Do not pry the heat sink off of the processor.  6. Lift the heat sink off of the processor and set the heat sink upside down so as

Strona 49 - Spare Bank Support

 15. Press <F2> to enter the System Setup program, and check that the processor information matches the new system configuration. See your Us

Strona 50 - Removing Memory Modules

Back to Contents Page  Installing Drives Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Optical Drive SCSI Configurat

Strona 51 - Processor

 2. Rotate the drive downward until it snaps into place.  3. Connect the interposer card to the optical drive.  4. Push the plungers into t

Strona 52

Remove the CD drive if you are removing hard drive 0. See "Removing the Optical Drive."  3. Disconnect the power and interface cables from

Strona 53

Installing a Hard Drive   1. Align the hard-drive mounting holes with the holes in the drive carrier.  2. Using a #2 Phillips screwdriver, insta

Strona 54 -  Installing Drives

Back to Contents Page  Getting Help Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Technical Assistance Dell Enterpri

Strona 55 - Hard Drives

support.jp.dell.com (Japan only) support.euro.dell.com (Europe only) l Electronic Quote Service [email protected] [email protected] (Asian/Pacific c

Strona 56

Back to Contents Page  I/O Connectors Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Serial Connector PS/2-Compatible

Strona 57 - Installing a Hard Drive

the system diagnostics.  4. Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diske

Strona 58 -  Getting Help

Country (City) International Access Code Country Code City Code Department Name or Service Area, Website and E-Mail Address Area Codes, Local Numbers,

Strona 59 - Product Information

Sales (med./large bus., government) toll-free:1-800-387-5755 Spare Parts Sales & Extended Service Sales 18664403355 Cayman Islands General Sup

Strona 60 - Contacting Dell

Fax 0925331399 Switchboard 0925331300 France (Paris) (Montpellier) International Access Code: 00 Country Code: 33 City Codes: (1) (4) Website: s

Strona 61

City Code: 1 Corporate Customer Care (dial within U.K. only) 08709074499 Ireland Sales 012044444 U.K. Sales (dial within U.K. only) 08709074000

Strona 62

Country Code: 853 Customer Service (Penang, Malaysia) 6046334949 Transaction Sales toll-free:0800581 Malaysia (Penang) International Access Code:

Strona 63

Panama General Support 001-800-507-0962 Peru General Support 0800-50-669 Poland (Warsaw) International Access Code: 011 Country Code: 48 City Code: 22

Strona 64

Switzerland (Geneva) International Access Code: 00 Country Code: 41 City Code: 22 Website: support.euro.dell.com  E-mail: Tech_support_central_Europ

Strona 65

Back to Contents Page  Spare Parts Sales toll-free:1-800-357-3355 Extended Service and Warranty Sales toll-free:1-800-247-4618 Fax toll-free:1-800

Strona 66

Back to Contents Page Dell™PowerEdge™SC1425SystemsInstallationandTroubleshootingGuide Notes, Notices, and Cautions Abbreviations and Acron

Strona 67

Table B-2.SerialConnectorPinAssignments PS/2-Compatible Keyboard and Mouse Connectors The PS/2-compatible keyboard and mouse cables attach t

Strona 68

USB Connectors The system's USB connectors support USB-compliant peripherals such as keyboards, mice, and printers and may also support USB-com

Strona 69 - Abbreviations and Acronyms

Network Cable Requirements The NIC supports a UTP Ethernet cable equipped with a standard RJ45-compatible plug. Observe the following cabling restr