Dell Powervault NX400 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Dell Powervault NX400. Dell Powervault NX400 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Owner's Manual

Dell PowerVault NX400 SystemsOwner's ManualRegulatory Model: E18S SeriesRegulatory Type: E18S001

Strona 2 - Notes, Cautions, and Warnings

Item Indicator, Button, or ConnectorIcon Description5 LCD menu buttons Allows you to navigate the control panel LCD menu.6 LCD panel Displays system I

Strona 4

7Technical SpecificationsProcessorProcessor type Intel Xeon processor E5-2420 product family, orIntel Xeon processor E5-2403 product familyExpansion B

Strona 5

ConnectorsBackNIC Two 10/100/1000 MbpsSerial 9-pin, DTE, 16550-compatibleUSB Two 4-pin, USB 2.0-compliantVideo 15-pin VGAiDRAC7 One optional 1 GbE Eth

Strona 6

EnvironmentalNOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event L

Strona 8

8System MessagesLCD MessagesNOTE: Applicable only if your system has an LCD display.The LCD messages consist of brief text messages that refer to even

Strona 9 - About Your System

Error Code Message InformationAMP0302Message The system board <name> current is greater than the upper warning threshold.Details System board &l

Strona 10 - LCD Panel Features

Error Code Message InformationASR0003Message The watchdog timer power cycled the system.Details The operating system or an application failed to commu

Strona 11 - Setup Menu

Error Code Message InformationAction Review the technical specifications for supported processor types.CPU0010Message CPU <number> is throttled.

Strona 12 - Hard-Drive Indicator Patterns

Error Code Message Information2. Turn off the system and remove input power for one minute. 3. Ensure the processor is seated correctly.4. Reapply

Strona 13

Item Button Description1 Left Moves the cursor back in one-step increments.2 Select Selects the menu item highlighted by the cursor.3 Right Moves the

Strona 14 - NIC Indicator Codes

Error Code Message Information5. If the issue persists, see Getting Help.FAN0000Message Fan <number> RPM is less than the lower warning thresh

Strona 15

Error Code Message InformationAction Check if the cable is present, then reinstall or reconnect.MEM0000Message Persistent correctable memory errors de

Strona 16 - Getting Started Guide

Error Code Message InformationLCD Message Memory mirror lost on <location>. Power cycle system.Details The memory may not be seated correctly, m

Strona 17 - Choosing The System Boot Mode

Error Code Message InformationAction Cycle input power, update component drivers, if device is removable, reinstall the device.PCI1320Message A bus fa

Strona 18 - System Setup Options

Error Code Message InformationLCD Message Drive <number> removed from disk drive bay <bay>. Check drive.Details The controller detected th

Strona 19 - System Information Screen

Error Code Message InformationPSU0006Message Power supply <number> type mismatch.LCD Message Power supply <number> is incorrectly configur

Strona 20 - Processor Settings Screen

Error Code Message InformationPSU0034Message An under voltage fault detected on power supply <number>.LCD Message An under voltage fault detecte

Strona 21 - SATA Settings Screen

Error Code Message InformationPSU1201Message Power supply redundancy is lost.Details The power supply tries to operate in a degraded state. System Per

Strona 22 - Integrated Devices Screen

Error Code Message InformationDetails An error was reported during a SD card read or write.Action Reseat the flash media. If the problem persists, see

Strona 23 - Serial Communications Screen

Error Code Message InformationSEC0031Message The chassis is open while the power is on.LCD Message Intrusion detected. Check chassis cover.Details The

Strona 24

View MenuNOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next action.Option DescriptioniDRAC IP

Strona 25 - System Security Screen

Error Code Message InformationAction Re-configure system to the minimum supported configuration. If issues persists, contact support.TMP0118Message Th

Strona 26 - Miscellaneous Settings

Error Code Message InformationAction1. Review system logs for power supply exceptions.2. Re-configure the system to minimum configuration, inspect and

Strona 28

9Getting HelpContacting DellNOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing

Strona 29 - Boot Manager Screen

Drive-Status Indicator Pattern (RAID Only)ConditionNOTE: The drive status indicator remains off until all hard drives are initialized after the system

Strona 30 - Embedded System Management

Item Indicator, Button, or ConnectorIcon Description4 Serial connector Allows you to connect a serial device to the system.5 PCIe expansion card slot

Strona 31

Indicator Indicator CodeLink and activity indicators are offThe NIC is not connected to the network.Link indicator is greenThe NIC is connected to a v

Strona 32

Power Indicator PatternConditionCAUTION: If two power supplies are used, they must be of the same type and have the same maximum output power.Flashing

Strona 33 - Installing System Components

2Using The System Setup And Boot ManagerSystem Setup enables you to manage your system hardware and specify BIOS-level options.The following keystroke

Strona 34 - Opening The System

mode. Thereafter, you must boot the system in the same boot mode (BIOS or UEFI) to access the installed operating system. Trying to boot the operating

Strona 35 - Inside The System

System Setup Main ScreenNOTE: Press <Alt><F> to reset the BIOS or UEFI settings to their default settings.Menu Item DescriptionSystem BIOS

Strona 36

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Strona 37 - Cooling Shroud

Menu Item DescriptionSystem Service Tag Displays the system Service Tag.System Manufacturer Displays the name of system manufacturer.System Manufactur

Strona 38 - Installing The Cooling Shroud

Menu Item DescriptionVirtualization TechnologyAllows you to enable or disable the additional hardware capabilities provided for virtualization. By def

Strona 39 - System Memory

Menu Item DescriptionPort C Auto enables BIOS support for the device attached to SATA port C. By default, Port C is set to Auto.Port D Auto enables BI

Strona 40

Menu Item DescriptionUser Accessible USB PortsAllows you enable or disable the user accessible USB ports. Selecting Only Back Ports On disables the fr

Strona 41 - Mode-Specific Guidelines

Menu Item DescriptionExternal Serial ConnectorAllows you to associate the external serial connector to serial device 1, serial device 2, or remote acc

Strona 42 - Sample Memory Configurations

Menu Item DescriptionMemory Refresh Rate Allows you to set the memory refresh rate. By default, the Memory Refresh Rate option is set to 1x.Memory Ope

Strona 43 - Removing Memory Modules

Menu Item DescriptionAC Power Recovery Allows you to set how the system reacts after AC power is restored to the system. By default, the AC Power Reco

Strona 44 - Installing Memory Modules

Assigning A System And/Or Setup PasswordNOTE: The password jumper enables or disables the System Password and Setup Password features. For more inform

Strona 45 - Hard Drives

The System Security screen is displayed.4. In the System Security screen, verify that Password Status is Unlocked.5. Select System Password, alter or

Strona 46

Entering The UEFI Boot ManagerNOTE: Operating systems must be 64-bit UEFI-compatible (for example, Microsoft Windows Server 2008 x64 version) to be in

Strona 47

ContentsNotes, Cautions, and Warnings...21 About Your

Strona 48 - Optical Drive (Optional)

Menu Item DescriptionBIOS Boot Menu Displays the list of available BIOS boot options (marked with asterisks). Select the boot option you wish to use a

Strona 49 - Cooling Fans

3. In the System Setup Main Menu page, click iDRAC Settings.The iDRAC Settings screen is displayed.31

Strona 51

3Installing System ComponentsRecommended ToolsYou may need the following items to perform the procedures in this section:• Key to the system keylock•

Strona 52

Removing The Front Bezel1. Unlock the keylock at the left end of the bezel.2. Lift the release latch next to the keylock.3. Rotate the left end of the

Strona 53 - Removing An Expansion Card

Figure 9. Opening and Closing the System1. system cover2. latch3. latch release lockClosing The System1. Lift the latch on the cover.2. Place the cove

Strona 54 - Installing An Expansion Card

Figure 10. Inside the System—With Redundant Power Supplies1. power distribution board shroud2. cooling shroud3. power supplies (2)4. integrated storag

Strona 55

Figure 11. Inside the System—With a Non-Redundant Power Supply1. cooling shroud2. power supply3. integrated storage controller card4. expansion-card r

Strona 56

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and peripherals.2. Open the system.3.

Strona 57 - Removing The iDRAC Ports Card

4. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.System MemoryYour system supports DDR3 unb

Strona 58 - SD vFlash Card

Entering The UEFI Boot Manager...

Strona 59 - Internal Dual SD Module

Figure 13. Memory Socket LocationsMemory channels are organized as follows:• Channel 0: memory sockets A1 and A4• Channel 1: memory sockets A2 and A5•

Strona 60

DIMM Type DIMMs Populated/ChannelOperating Frequency (in MT/s) Maximum DIMM Rank/Channel1.5 V 1.35 V1333, 1066, and 800 1066 and 800 Quad rank21600, 1

Strona 61 - Internal SD Card

Memory Optimized (Independent Channel) ModeThis mode supports SDDC only for memory modules that use x4 device width and does not impose any specific s

Strona 62

System Capacity (in GB)DIMM Size (in GB) Number of DIMMs DIMM Rank, Organization, and FrequencyDIMM Slot Population12 4 3 2R, x8, 1333 MT/s, A1, A2, A

Strona 63 - Processor

Figure 14. Removing and Installing a Memory Module1. memory-module socket ejectors (2)2. memory module3. alignment key6. Install memory-module blanks

Strona 64

6. Align the memory module's edge connector with the alignment key of the memory module socket, and insert the memory module in the socket.NOTE:

Strona 65 - Installing A Processor

Figure 15. Removing and Installing a 3.5 Inch Hard-Drive Blank1. hard-drive blank2. release buttonInstalling A 3.5 Inch Hard-Drive Blank1. If installe

Strona 66 - Power Supplies

Figure 16. Removing and Installing a Hot-Swap Hard Drive1. release button2. hard drive3. hard-drive carrier handleInstalling A Hot-Swap Hard DriveCAUT

Strona 67

Optical Drive (Optional)Removing The Optical Drive In Hot-Swappable Hard-Drive SystemsCAUTION: Many repairs may only be done by a certified service te

Strona 68

Installing The Optical Drive In Hot-Swappable Hard-Drive SystemsCAUTION: Many repairs may only be done by a certified service technician. You should o

Strona 69

Installing An Expansion Card...

Strona 70 - System Battery

1. Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.2. Open the system.3. Remove the cool

Strona 71 - Hard-Drive Backplane

6. Replace the cooling shroud or power distribution board shroud as applicable.7. Close the system.8. Reconnect the system to its electrical outlet an

Strona 72

Expansion Cards And Expansion-Card RisersNOTE: A missing or an unsupported expansion-card riser logs an SEL event. It does not prevent your system fro

Strona 73 - 4. chassis hooks (4)

Removing An Expansion CardCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple

Strona 74

Figure 21. Removing and Installing the Expansion Card in Riser 21. expansion-card riser 22. expansion-card riser touch points3. expansion-card latch4.

Strona 75 - Control Panel Assembly

NOTE: Ensure that the expansion card is properly seated along the chassis, so that expansion-card latch can be closed.9. Slide the expansion-card hold

Strona 76 - Installing The Control Panel

Figure 23. Removing and Installing the Expansion-Card Riser 21. chassis intrusion switch2. expansion-card riser touch points (2)3. expansion-card rise

Strona 77

iDRAC Ports Card (Optional)The iDRAC Ports card supports:• one 1GbE Ethernet port• SD vFlash cardRemoving The iDRAC Ports CardCAUTION: Many repairs ma

Strona 78

1. expansion-card latch2. expansion-card riser touch points (2)3. expansion-card riser 14. iDRAC Ports card connector5. SD card slot6. RJ-45 Ethernet

Strona 79 - Power Distribution Board

Figure 25. Replacing the SD vFlash Card1. SD vFlash card2. SD vFlash card slot3. To install the SD vFlash card, with the label side facing up, insert

Strona 80

Removing The Power Distribution Board...79Instal

Strona 81 - System Board

Figure 26. Removing and Installing the Internal Dual SD Module1. blue pull tab2. SD card 13. SD card 24. dual SD module5. connector on the system boar

Strona 82 - Installing The System Board

7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.Internal SD CardRemoving An Internal SD Ca

Strona 83

Removing The Integrated Storage Controller CardCAUTION: Many repairs may only be done by a certified service technician. You should only perform troub

Strona 84

1. touch-points (2)2. storage controller card3. storage-controller card holder4. release levers (2)5. storage-controller card connectorInstalling The

Strona 85 - Troubleshooting Your System

Figure 28. Removing and Installing the Processor Heat Sink1. retention sockets (4)2. heat sink3. retention screws (4)CAUTION: The processor is held in

Strona 86 - Troubleshooting A Wet System

Figure 29. Removing and Installing a Processor1. processor2. processor shield3. notches in processor (2)NOTE: After removing the processor, place it i

Strona 87

WARNING: The heat sink and processor are hot to the touch for some time after the system has been powered down. Allow the heat sink and processor to c

Strona 88

output voltage of the active power supply. If the output voltage of the active power supply drops, the redundant power supply in the sleep state retur

Strona 89 - Troubleshooting System Memory

Installing A Redundant Power Supply1. Verify that both power supplies are the same type and have the same maximum output power.NOTE: The maximum outpu

Strona 90 - Troubleshooting An SD Card

Figure 31. Removing and Installing a Non-Redundant Power Supply1. power supply2. screw3. 24-pin power cable4. 8-pin power cable5. standoff6. SATA powe

Strona 91

7 Technical Specifications...1018 System Messages.

Strona 92 - Troubleshooting A Hard Drive

If you are installing a second power supply, remove the power supply blank in the bay by pulling outward on the blank.Figure 32. Removing and Installi

Strona 93

CAUTION: To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery.5. To remove the batte

Strona 94 - Troubleshooting Processors

CAUTION: To prevent damage to the drives and backplane, you must remove the hard drives from the system before removing the backplane.CAUTION: You mus

Strona 95 - Using System Diagnostics

Figure 36. Removing and Installing the Four Hard-Drive Backplane1. release tabs (2)2. hard-drive backplane3. guide pins (2)4. chassis hooks (4)73

Strona 96 - System Diagnostic Controls

Figure 37. Cabling Diagram—Four Hard-Drive Backplane1. system board2. hard-drive backplane3. SAS cable connector4. cable routing guide5. signal cable

Strona 97 - Jumpers And Connectors

Control Panel AssemblyRemoving The Control PanelCAUTION: Many repairs may only be done by a certified service technician. You should only perform trou

Strona 98 - System Board Connectors

Installing The Control PanelCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simp

Strona 99

Figure 39. Removing and Installing the Control-Panel Module1. control-panel module2. screws (2)3. control-panel module connector cable4. USB connector

Strona 100

Power Distribution Board ShroudRemoving The Power Distribution Board ShroudCAUTION: Many repairs may only be done by a certified service technician. Y

Strona 101 - Technical Specifications

Installing The Power Distribution Board ShroudCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubl

Strona 103

Figure 41. Removing and Installing the Power Distribution Board1. screws (2)2. power supply cables to the system board (3)3. power supply cable to the

Strona 104

System BoardRemoving The System BoardCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting

Strona 105 - System Messages

Figure 42. Removing and Installing the System Board1. screws (9)2. system boardInstalling The System BoardCAUTION: Many repairs may only be done by a

Strona 106

6. Reconnect all cables to the system board.NOTE: Ensure that the cables inside the system are routed through the cable routing latch.7. Close the sys

Strona 108

4Troubleshooting Your SystemSafety First—For You And Your SystemCAUTION: Many repairs may only be done by a certified service technician. You should o

Strona 109

7. Power down all attached USB devices and disconnect them from the system.8. Restart the system and, if your keyboard is functioning, enter the Syste

Strona 110

3. Disassemble components from the system:– Hard drives– Hard-drive backplane– USB memory key– Cooling shroud– Expansion-card risers (if present)– Exp

Strona 111

If the tests fail, see Getting Help.Troubleshooting The System BatteryCAUTION: Many repairs may only be done by a certified service technician. You sh

Strona 112

Troubleshooting Cooling ProblemsCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

Strona 113

1About Your SystemFront-Panel Features And IndicatorsFigure 1. Front-Panel Features and IndicatorsItem Indicator, Button, or ConnectorIcon Description

Strona 114

8. Reseat the memory modules in their sockets.9. Close the system.10. Enter the System Setup and check the system memory setting.If the problem is not

Strona 115

1. Enter the System Setup and ensure that the Internal SD Card Port is enabled.2. Turn off the system, including any attached peripherals, and disconn

Strona 116

1. Try using a different tape cartridge.2. Ensure that the device drivers for the tape backup unit are installed and are configured correctly. See you

Strona 117

NOTE: When troubleshooting a SAS or PERC controller, also see the documentation for your operating system and the controller.1. Run the appropriate di

Strona 118

10. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.If the tests fail, see Getting Help.11. For each expansion

Strona 119

5Using System DiagnosticsIf you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The

Strona 120

The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts executing the tests on all

Strona 121 - Warning Messages

6Jumpers And ConnectorsSystem Board Jumper SettingsFor information on resetting the password jumper to disable a password, see Disabling A Forgotten P

Strona 122

System Board ConnectorsFigure 43. System Board Jumpers and ConnectorsItem Connector Description1 INT_STORAGE Integrated storage controller card connec

Strona 123 - Getting Help

Item Connector Description15 PWR_CONN_1 Power connector16 Fan2 Cooling fan connector17 A1, A4, A2, A5, A3, A6 Memory module sockets18 BP_SIG Backplane