Strona 1 - Performance Considerations

www.dell.com | support.dell.comDell™ PowerVault™ SystemsPerformance Considerationsfor Tape Drives and Libraries

Strona 2

10 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comRAID 1Also known as mirroring, RAID 1 means data is written

Strona 3 - Contents

100 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.com

Strona 4 - 4 Contents

www.dell.com | support.dell.comDell™ PowerVault™ システムテープドライブとライブラリのパフォーマンスに関する考慮事項

Strona 5 - Introduction

____________________本書の内容は予告なく変更されることがあります。© 2005 すべての著作権は Dell Inc. にあります。Dell Inc. の書面による許可のない複製は、いかなる形態においても厳重に禁じられています。本書で使用されている商標について:Dell、DELL

Strona 6

目次 103目次はじめに . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105ホストのバックアップに関する一般的な考慮事項 . . . . . . . . . . 105テープドライブとデータに関する考慮事項

Strona 8 - General overview of RAID

テープドライブとライブラリのパフォーマンスに関する考慮事項 105はじめに最近はテープドライブの転送速度が向上したため、ホストサーバーとテープドライブが同じ速度でデータを処理できるかどうかを判断する際に、RAID(Redundant Array of Inexpensive [または Indepen

Strona 9

106 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.comドライバおよびファームウェア。SCSI またはファイバーコントローラとテープドライブに最新のドライバとファームウェアがインストールされていることを常に確認してください。su

Strona 10

テープドライブとライブラリのパフォーマンスに関する考慮事項 107テープドライブのパフォーマンスの確認テープドライブの製造元が、スループットの確認に使用できるパフォーマンス診断モードをドライブに組み込んでいる場合もあります。PowerVault 110T LTO-2 および LTO-3(ファームウェ

Strona 11

108 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.com図 1-1 シングルチャネルの帯域幅対 2 チャネルの帯域幅ハードドライブのパフォーマンステープドライブはデータの書き込みを連続して行うように設計されており、バックヒッチン

Strona 12 - Drives in Tape Libraries

テープドライブとライブラリのパフォーマンスに関する考慮事項 109ファイルが小さいほど、ドライブはファイルをディスクとの間で読み取り / 書き込みするための「シーク」が多くなります。したがって、多くの小さなファイルを転送する際には、ディスクの読み取り / 書き込みが非常に遅くなりがちです。順次的 /

Strona 13 - SAN Configurations

Performance Considerations for Tape Drives and Libraries 11RAID 5With a RAID 5 array, data is striped across the disk array at the byte level and erro

Strona 14

110 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.comRAID 0RAID 0 では、2 台以上のディスクを結合して、1 つの LUN のように 1 つの仮想ドライブを作成する(一般に「ストライピング」と呼ばれています)ことが

Strona 15

テープドライブとライブラリのパフォーマンスに関する考慮事項 111RAID 1RAID 1 では、データが 2 つのディスクにまたがって 2 度同時に書き込まれます(「ミラーリング」とも呼ばれます)。1 台のドライブに障害が発生した場合、システムはデータを失うことなく、もう一方のドライブへの切り替え

Strona 16

112 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.comRAID 5RAID 5 アレイでは、データはバイトレベルでディスクアレイにまたがってストライピングされ、エラー訂正データまたはパリティデータも、ディスクアレイにまたがって

Strona 17

テープドライブとライブラリのパフォーマンスに関する考慮事項 113結論として、RAID 0 は読み取り / 書き込みのパフォーマンスにとっては総合的に最適な構成である場合が多いと言えますが、冗長性は提供しません。RAID 1 では、アレイに書き込まれるすべてのデータがミラーリングされ、読み取りもシン

Strona 18

114 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.comSAN 構成ファイバーチャネル(FC)は多くの点で SCSI よりも優れています。まず、SCSI の距離制限が克服されており(LVD SCSI では 12 m なのに対して

Strona 19

テープドライブとライブラリのパフォーマンスに関する考慮事項 115図 1-6 テープライブラリへのデータフロー:シングルと分割の比較同時に、外付けの FC ディスクアレイから読み取られるデータにボトルネックが存在する場合は、EMC® PowerPath® などの I/O 管理ソフトウェアを追加のファ

Strona 20

116 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.com図 1-7 ボトルネックの発生したデータフローと負荷分散されたディスクアレイの比較最後に、SAN 上の FC ディスクアレイでも、「ハードドライブと RAID アレイの構成

Strona 21

テープドライブとライブラリのパフォーマンスに関する考慮事項 117推奨するケーブル設定ホストへの SCSI ケーブル接続6 台までのテープドライブを備えたテープライブラリテープライブラリをホストに SCSI 接続する場合は、シングルバスに 3 台以上のドライブを接続しないでください。SCSI バスが

Strona 22

118 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.comただし、バックアップアプリケーションの検証機能を有効にするお客様は、2 台のドライブを 2 つの SCSI バスに分割することで、検証パフォーマンスを向上することが可能です

Strona 23

テープドライブとライブラリのパフォーマンスに関する考慮事項 119図 1-10 テープドライブが 1 台の場合のファイバーチャネルブリッジのケーブル接続ライブラリ SCSI インタフェースSCSI 1ターミネータドライブ 1

Strona 24

12 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comIn conclusion, RAID 0 tends to be the best overall configura

Strona 25 - 磁带驱动器和磁带存储库

120 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.com図 1-11 テープドライブが 2 台の場合のファイバーチャネルブリッジのケーブル接続ライブラリ SCSI インタフェースSCSI 1SCSI 2ターミネータターミネータド

Strona 26

テープドライブとライブラリのパフォーマンスに関する考慮事項 121図 1-12 テープドライブが 3 台の場合のファイバーチャネルブリッジのケーブル接続ライブラリ SCSI インタフェースSCSI 1SCSI 2ターミネータターミネータドライブ 1ドライブ 2ドライブ 3

Strona 27

122 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.com図 1-13 テープドライブが 4 台の場合のファイバーチャネルブリッジのケーブル接続図 1-14 1 台から 4 台のドライブを備えたテープライブラリ用のチャネルゾーニン

Strona 28

テープドライブとライブラリのパフォーマンスに関する考慮事項 123図 1-15 テープドライブが 5 台の場合のファイバーチャネルブリッジのケーブル接続ライブラリ SCSI インタフェースSCSI 1SCSI 2SCSI 3SCSI 4ドライブ 1ターミネータドライブ 2ドライブ 3ターミネータドラ

Strona 29 - 主机备份一般注意事项

124 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.com図 1-16 テープドライブが 6 台の場合のファイバーチャネルブリッジのケーブル接続図 1-17 5 台または 6 台のドライブを備えたテープライブラリ用のチャネルゾーニ

Strona 30 - 硬盘驱动器配置一般注意事项

テープドライブとライブラリのパフォーマンスに関する考慮事項 125図 1-18 と 図 1-19 は、ファイバーチャネルを介してテープのパフォーマンスを最適化するために、ファイバーチャネルブリッジモジュールを用いて最大 2 台のドライブを備えたテープライブラリを構成する方法を示したものです。図 1-

Strona 31

126 テープドライブとライブラリのパフォーマンスに関する考慮事項www.dell.com | support.dell.com

Strona 32 - 磁带驱动器和磁带存储库性能注意事项

www.dell.com | support.dell.comDell™ PowerVault™ 시스템테이프 드라이브및 라이브러리의성능 고려사항

Strona 33

____________________본 설명서에 수록된 정보는 사전 통보 없이 변경될 수 있습니다.© 2005 Dell Inc. All rights reserved.어떠한 경우에도 Dell Inc.의 사전 승인 없이 무단 복제하는 행위는 엄격하게 금지되어 있습니다.본

Strona 34

차례 129차례도입 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131일반적인 호스트 백업 고려사항 . . . . . . . . . . . . . . . . . . . . 131테이프

Strona 35

Performance Considerations for Tape Drives and Libraries 13SAN ConfigurationsFibre Channel (FC) offers many advantages over SCSI. First, it overcomes

Strona 37

테이프 드라이브 및 라이브러리의 성능 고려사항 131도입최근 테이프 드라이브의 전송률 향상으로 인해 호스트 서버와 테이프 드라이브에서 동일한 속도로 데이터를 처리할 수 있는지의 여부를 결정할 때 RAID 구성과 하드 드라이브 사양과 같은 많은 호스트 측 요소들이 고려되

Strona 38 - 使用存储库光纤信道桥接器进行

132 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.com테이프 드라이브와 하드 드라이브를 별도의 HBA(호스트 버스 어댑터)의 개별 컨트롤러(내부 또는 외부)에 연결하십시오. 이 사항은 컨트롤러의 성능에 다소 영향을

Strona 39

테이프 드라이브 및 라이브러리의 성능 고려사항 133일반적인 하드 드라이브 구성 고려사항여러 LUN에서의 데이터/운영 체제(OS). OS LUN(Logical Unit Number)과는 별도로 LUN 상의 데이터를 백업하면 하드 드라이브에서 OS 작업과 백업 작업 간의

Strona 40

134 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.com임의 액세스 시간 또는 탐색 시간. 일반적으로 밀리초로 측정되는 탐색 시간은 드라이브 헤드가 디스크상의 데이터를 찾는 데 걸리는 시간을 의미합니다. 하드 디스크의

Strona 41

테이프 드라이브 및 라이브러리의 성능 고려사항 135RAID 0흔히 스트라이핑이라고 하는 RAID 0은 두 개 이상의 디스크를 연결하여 단일 LUN 방식으로 하나의 가상 드라이브를 생성할 수 있습니다. RAID 0을 스트라이핑이라고 일컫는 이유는 데이터가 한번에 하나의

Strona 42 - 42 磁带驱动器和磁带存储库性能注意事项

136 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.comRAID 1미러링이라고도 하는 RAID 1은 데이터가 두 개의 디스크에 동시에 두 번에 걸쳐 쓰여집니다. 하나의 드라이브에 오류가 있으면 시스템은 다른 드라이브로

Strona 43

테이프 드라이브 및 라이브러리의 성능 고려사항 137RAID 5RAID 5 배열에서 데이터는 바이트 레벨에서 디스크 배열 전체에 걸쳐 저장되며 오류 수정 데이터, 즉 패리티 데이터 또한 디스크 배열 전체에 저장됩니다. RAID 5 배열은 매우 양호한 임의 읽기 성능을

Strona 44 - 44 磁带驱动器和磁带存储库性能注意事项

138 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.com요약하면 RAID 0은 전체적으로 읽기 및 쓰기 성능 측면에서 최상의 구성이지만 중복성을 허용하지 않습니다. RAID 1은 전체적인 성능에서는 가장 뒤떨어지지만

Strona 45

테이프 드라이브 및 라이브러리의 성능 고려사항 139SAN 구성Fibre Channel(FC)은 SCSI에 비해 많은 이점을 제공합니다. 우선 FC는 SCSI의 거리 제약을 극복하고(LVD SCSI의 12미터 vs. 단파 2Gb FC 링크의 300미터) 고속 데이터 전

Strona 46 - 46 磁带驱动器和磁带存储库性能注意事项

14 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comFigure 1-6. Single vs. Split Data Flow to Tape LibraryAt the

Strona 47

140 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.com그림 1-6. 테이프 라이브러리로의 단일 및 분할 데이터 흐름또한, 외부 FC 디스크 배열에서 읽는 데이터에 병목이 존재하는 경우, 추가적인 구조 연결과 함께 E

Strona 48 - 48 磁带驱动器和磁带存储库性能注意事项

테이프 드라이브 및 라이브러리의 성능 고려사항 141그림 1-7. 병목 상태의 데이터 흐름 vs. 부하 조정된 디스크 배열마지막으로 SAN의 FC 디스크 배열 또한 "하드 드라이브 및 RAID 배열 구성"에서 설명하는 동일한 성능 제한 현상을 경험할

Strona 49 - Remarques sur

142 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.com권장 케이블 연결 구성호스트에 SCSI 케이블 연결최대 6개의 테이프 드라이브로 구성된 테이프 라이브러리테이프 라이브러리가 호스트에 SCSI로 연결된 경우, 단일

Strona 50

테이프 드라이브 및 라이브러리의 성능 고려사항 143그림 1-9. 최대 2 개 테이프 드라이브로 구성된 라이브러리의 SCSI 케이블 연결드라이브를 Fibre Channel 브릿지에 연결그림 1-10부터 1-17까지는 FC 상에서의 테이프 성능을 최적화하기 위해 최대 6

Strona 51 - Sommaire

144 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.com그림 1-10. Fibre Channel 브릿지를 단일 테이프 드라이브에 연결라이브러리 SCSI 인터페이스SCSI 1터미네이터드라이브 1

Strona 52 - 52 Sommaire

테이프 드라이브 및 라이브러리의 성능 고려사항 145그림 1-11. Fibre Channel 브릿지를 2 개 테이프 드라이브에 연결라이브러리 SCSI 인터페이스SCSI 1SCSI 2터미네이터터미네이터드라이브 1드라이브 2

Strona 53 - Présentation

146 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.com그림 1-12. Fibre Channel 브릿지를 3 개 테이프 드라이브에 연결라이브러리 SCSI 인터페이스SCSI 1SCSI 2터미네이터터미네이터드라이브 1드라

Strona 54

테이프 드라이브 및 라이브러리의 성능 고려사항 147그림 1-13. Fibre Channel 브릿지를 4 개 테이프 드라이브에 연결그림 1-14. 1 ~ 4 개 드라이브로 구성된 테이프 라이브러리의 Channel Zoning 설정라이브러리 SCSI 인터페이스SCSI 1

Strona 55

148 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.com그림 1-15. Fibre Channel 브릿지를 5 개 테이프 드라이브에 연결라이브러리 SCSI 인터페이스SCSI 1SCSI 2SCSI 3SCSI 4드라이브 1

Strona 56 - Performances des disques durs

테이프 드라이브 및 라이브러리의 성능 고려사항 149그림 1-16. Fibre Channel 브릿지를 6 개 테이프 드라이브에 연결그림 1-17. 5 개 또는 6 개 드라이브로 구성된 테이프 라이브러리의 Channel Zoning 설정라이브러리 SCSI 인터페이스SCS

Strona 57

Performance Considerations for Tape Drives and Libraries 15Figure 1-7. Bottlenecked Data Flow vs. Load-Balanced Disk ArrayFinally, FC disk arrays on t

Strona 58

150 테이프 드라이브 및 라이브러리의 성능 고려사항www.dell.com | support.dell.com그림 1-18 및 1-19는 FC 상에서의 테이프 성능을 최적화하기 위해 최대 2개의 드라이브로 구성된 테이프 라이브러리를 Fibre Channel 브릿지 모듈로

Strona 59

www.dell.com | support.dell.comSistemas Dell™ PowerVault™Consideraciones sobreel rendimiento de lasunidades de cinta y lasbibliotecas de cintas

Strona 60

____________________La información contenida en este documento puede modificarse sin previo aviso.© 2005 Dell Inc. Reservados todos los derechos.Queda

Strona 61 - Configurations SCSI

Índice 153ÍndiceIntroducción . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155Consideraciones generales sobre la copia de segu

Strona 63

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 155IntroducciónCon la reciente introducción de mejoras en la

Strona 64

156 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comCuanto mayor sea el búfer,

Strona 65

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 157Confirmación del rendimiento de la unidad de cintaAlgunos

Strona 66 - Terminaison

158 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comFigura 1-1. Amplitud de ba

Strona 67

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 159Este atributo es muy significativo cuando una unidad de d

Strona 68

16 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comRecommended Cabling ConfigurationsSCSI Cabling to the HostTa

Strona 69

160 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comRAID 0RAID 0, conocida tam

Strona 70

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 161RAID 1RAID 1, conocida también como duplicación, consiste

Strona 71

162 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comFigura 1-3. Ejemplo de con

Strona 72

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 163Las restauraciones de una cinta a una matriz RAID 5 tiend

Strona 73

164 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comLas operaciones de copia d

Strona 74

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 165Configuraciones de SANFibre Channel (FC) presenta muchas

Strona 75 - Leistungsoptimierung

166 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comCuando se identifica un cu

Strona 76

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 167Figura 1-7. Flujo de datos con cuello de botella frente a

Strona 77

168 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comConfiguraciones de cablead

Strona 78 - 78 Inhalt

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 169Biblioteca de cintas con hasta dos unidades de cintaLas u

Strona 79 - Einführung

Performance Considerations for Tape Drives and Libraries 17Figure 1-9. SCSI Cabling for Library With up to Two Tape DrivesCabling Drives to the Fibre

Strona 80

170 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comCableado de las unidades a

Strona 81

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 171Figura 1-11. Cableado del puente Fibre Channel con dos un

Strona 82 - Festplattenleistung

172 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comFigura 1-12. Cableado del

Strona 83 - RAID – Allgemeine Übersicht

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 173Figura 1-13. Cableado del puente Fibre Channel con cuatro

Strona 84

174 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comFigura 1-14. Configuración

Strona 85

Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintas 175Figura 1-16. Cableado del puente Fibre Channel con seis u

Strona 86

176 Consideraciones sobre el rendimiento de las unidades de cinta y las bibliotecas de cintaswww.dell.com | support.dell.comEn las figuras 1-18 y 1-19

Strona 87 - SCSI-Konfigurationen

18 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comFigure 1-10. Fibre Channel Bridge Cabling With One Tape Driv

Strona 88 - SAN-Konfigurationen

Performance Considerations for Tape Drives and Libraries 19Figure 1-11. Fibre Channel Bridge Cabling With Two Tape Driveslibrary SCSI interfaceSCSI 1S

Strona 89

____________________Information in this document is subject to change without notice.© 2005 Dell Inc. All rights reserved.Reproduction in any manner w

Strona 90

20 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comFigure 1-12. Fibre Channel Bridge Cabling With Three Tape Dr

Strona 91 - SCSI-Kabelverbindung zum Host

Performance Considerations for Tape Drives and Libraries 21Figure 1-13. Fibre Channel Bridge Cabling With Four Tape DrivesFigure 1-14. Channel Zoning

Strona 92 - Abschlusswiderstand

22 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comFigure 1-15. Fibre Channel Bridge Cabling With Five Tape Dri

Strona 93

Performance Considerations for Tape Drives and Libraries 23Figure 1-16. Fibre Channel Bridge Cabling With Six Tape DrivesFigure 1-17. Channel Zoning S

Strona 94

24 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comFigure 1-18 and Figure 1-19 illustrate how a tape library wi

Strona 95

www.dell.com | support.dell.comDell™ PowerVault™ 系统磁带驱动器和磁带存储库性能注意事项

Strona 96

____________________本文件中的信息如有更改,恕不另行通知。© 2005 Dell Inc. 版权所有,翻印必究。未经 Dell Inc. 书面许可,严禁以任何方式进行复制。本文中使用的商标:Dell、DELL 徽标和 PowerVault 是 Dell Inc. 的商标; EMC

Strona 97

目录 27目录简介 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29主机备份一般注意事项. . . . . . . . . . . . . . . . . . . . . . . .

Strona 98

28 目录

Strona 99 - FC zu optimieren

磁带驱动器和磁带存储库性能注意事项 29简介随着近来磁带驱动器传输速率的提高,在确定主机服务器和磁带驱动器能否以相同速率处理数据时,必须考虑许多主机方面的因素,如 RAID(廉价[或独立]磁盘冗余阵列)配置和硬盘驱动器的规格。在“主机备份一般注意事项”中,将讨论可能会限制从主机服务器到磁带驱动器吞吐

Strona 100

Contents 3ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5General Host Backup Considerations. . . . .

Strona 101 - パフォーマンスに関する考慮事項

30 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com有污垢的驱动器磁头或旧的介质。有污垢的磁带驱动器磁头或旧的介质可能会导致很高的错误率,并相应地降低读/写速度。每次驱动器尝试在磁带上重写或重读区块时,性能都会下降。一旦到达了读/写错误的某个阈值,驱

Strona 102 - ____________________

磁带驱动器和磁带存储库性能注意事项 31图 1-1.单信道与双信道带宽硬盘驱动器性能根据设计,磁带驱动器应按顺序写入数据,并要求稳定的数据传输,以确保驱动器按顺序操作(避免出现后系留现象)。相反,硬盘驱动器是随机访问设备。因此,如果数据广泛分布在驱动器盘片上,则硬盘驱动器有时需要尽量向磁带驱动器按顺

Strona 103

32 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com硬件 RAID 配置注意事项RAID 概述本节概述了典型的 RAID 配置以及它们如何影响备份和恢复速率。RAID 阵列是一组可作为单一存储系统或 LUN 的硬盘。由于可以一次通过每个硬盘驱动器的信

Strona 104

磁带驱动器和磁带存储库性能注意事项 33图 1-2.示例 RAID 0 配置RAID 1RAID 1 也称作镜像,它意味着将数据同时写入两个磁盘中。如果其中一个驱动器出现故障,系统将切换到另一个驱动器,数据将不会丢失。在磁带驱动器备份期间,从 RAID 1 阵列读取数据的速率大约与从单一驱动器读取数

Strona 105 - ホストのバックアップに関する一般的な考慮事項

34 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com图 1-3.示例 RAID 1 配置RAID 5使用 RAID 5 阵列,数据以字节级方式分拆到磁盘阵列中,且纠错数据或奇偶校验数据也分拆到磁盘阵列中。RAID 5 阵列具有非常好的随机读取性能,随

Strona 106 - テープドライブとライブラリのパフォーマンスに関する考慮事項

磁带驱动器和磁带存储库性能注意事项 35图 1-4.示例 RAID 5 配置总之,RAID 0 可以获得读和写性能的最佳整体配置,但没有考虑冗余性能。RAID 1 总体上效果最差,因为需要对所有写入阵列的数据进行镜像,且读取数据时只涉及一个磁盘。RAID 5 的读性能很好,但写性能一般;然而,如果阵

Strona 107 - ハードドライブと RAID アレイの構成

36 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com在磁带存储库中使用多个驱动器时的一般性能注意事项同时使用多个磁带驱动器执行数据备份时(如在磁带存储库中),就必须考虑硬盘配置的其它方面。通过使用简单的注重性能的方式设置硬盘和布线配置,可以限制发生额

Strona 108 - ハードドライブのパフォーマンス

磁带驱动器和磁带存储库性能注意事项 37在 SAN 中设置磁带存储库时,性能仍然会受到各种因素的影响。包括 FC 链路速度,源与磁带存储库之间的数据流,以及外部存储阵列的性能限制。随着对解决方案的总体设置和管理的逐步了解,可以避免其中的许多因素。即使 SAN 中的 FC 协议提供了很高的数据带宽,也

Strona 109 - ハードウェア RAID 構成に関する考慮事項

38 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com图 1-7.瓶颈数据流与负载均衡磁盘阵列最后,SAN 上的 FC 磁盘阵列也可能会遇到在“硬盘驱动器和 RAID 阵列配置”中介绍的相同的性能限制因素。因此,通过改进磁盘阵列的性能特性,可直接影响到

Strona 110 - 図 1-2 RAID 0 構成の例

磁带驱动器和磁带存储库性能注意事项 39建议的布线配置SCSI 与主机之间的布线配有最多六个磁带驱动器的磁带存储库当磁带存储库通过 SCSI 连接到主机时,应确保单一总线上不超过两个驱动器。对于配有五至六个磁带驱动器的存储库,需添加其它 SCSI 控制器,以确保 SCSI 总线不会成为障碍,从而实现

Strona 112 - 図 1-4 RAID 5 構成の例

40 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com图 1-9.配有最多两个磁带驱动器的存储库的 SCSI 布线将驱动器连接至光纤信道桥接器图 1-10 至图 1-17 图示说明了如何使用光纤信道桥接器模块配置一个配有最多六个驱动器的磁带存储库,以便

Strona 113 - フォーマンスに関する一般的な考慮事項

磁带驱动器和磁带存储库性能注意事项 41图 1-10.采用一个磁带驱动器时的光纤信道桥接器布线存储库 SCSI 接口SCSI 1终结处理器驱动器 1

Strona 114 - 図 1-5 ファイバーチャネルリンクの図

42 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com图 1-11.采用两个磁带驱动器时的光纤信道桥接器布线存储库 SCSI 接口SCSI 1SCSI 2终结处理器终结处理器驱动器 1驱动器 2

Strona 115

磁带驱动器和磁带存储库性能注意事项 43图 1-12.采用三个磁带驱动器时的光纤信道桥接器布线存储库 SCSI 接口SCSI 1SCSI 2终结处理器终结处理器驱动器 1驱动器 2驱动器 3

Strona 116

44 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com图 1-13.采用四个磁带驱动器时的光纤信道桥接器布线图 1-14.配有一到四个驱动器的磁带存储库的信道分区设置存储库 SCSI 接口SCSI 1SCSI 2终结处理器终结处理器驱动器 1驱动器 2

Strona 117 - ホストへの SCSI ケーブル接続

磁带驱动器和磁带存储库性能注意事项 45图 1-15.采用五个磁带驱动器时的光纤信道桥接器布线存储库 SCSI 接口SCSI 1SCSI 2SCSI 3SCSI 4驱动器 1终结处理器驱动器 2驱动器 3终结处理器驱动器 4驱动器 5终结处理器

Strona 118 - ファイバーチャネルブリッジへのドライブのケーブル接続

46 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com图 1-16.采用六个磁带驱动器时的光纤信道桥接器布线图 1-17.配有五或六个驱动器的磁带存储库的信道分区设置存储库 SCSI 接口SCSI 3SCSI 4SCSI 1SCSI 2驱动器 1终结处

Strona 119 - ライブラリ SCSI

磁带驱动器和磁带存储库性能注意事项 47图 1-18 和图 1-19 图示说明了如何使用光纤信道桥接器模块配置一个配有最多两个磁带驱动器的磁带存储库,以便通过 FC 优化磁带性能。图 1-18.配有一个驱动器的磁带存储库图 1-19.配有两个驱动器的磁带存储库终结处理器终结处理器终结处理器

Strona 120

48 磁带驱动器和磁带存储库性能注意事项www.dell.com | support.dell.com

Strona 121

www.dell.com | support.dell.comSystèmes Dell™ PowerVault™Remarques surles performancesdes lecteurs et desbibliothèques de bandes

Strona 122

Performance Considerations for Tape Drives and Libraries 5IntroductionWith recent improvements in tape drive transfer rates, many host-side factors, s

Strona 123

____________________Les informations contenues dans ce document peuvent être modifiées sans préavis.© 2005 Dell Inc. Tous droits réservés.La reproduct

Strona 124

Sommaire 51SommairePrésentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Remarques générales sur la sauvegarde du sys

Strona 126

Remarques sur les performances des lecteurs et des bibliothèques de bandes 53PrésentationRécemment, les vitesses de transfert des lecteurs de bande on

Strona 127 - 및 라이브러리의

54 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comTaille de tampon du logiciel de sauvegarde

Strona 128

Remarques sur les performances des lecteurs et des bibliothèques de bandes 55Vérification des performances du lecteur de bandeCertains fabricants de l

Strona 129

56 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comFigure 1-1. Bande passante simple canal/do

Strona 130

Remarques sur les performances des lecteurs et des bibliothèques de bandes 57Vitesses de transfert séquentielles/moyennes (STR). Ce paramètre correspo

Strona 131 - 일반적인 호스트 백업 고려사항

58 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comLa figure 1-2 montre quatre disques durs c

Strona 132 - 하드 드라이브 및 RAID 배열 구성

Remarques sur les performances des lecteurs et des bibliothèques de bandes 59Cependant, la vérification ECC (vérification et correction d'erreurs

Strona 133 - 하드 드라이브 성능

6 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comAttach tape drives and hard drives on separate controllers (i

Strona 134 - 하드웨어 RAID 구성 고려사항

60 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comPlus la matrice contient de disques, plus

Strona 135

Remarques sur les performances des lecteurs et des bibliothèques de bandes 61En résumé, la configuration RAID 0 offre généralement les meilleures perf

Strona 136

62 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comConfigurations SANLa technologie Fibre Cha

Strona 137

Remarques sur les performances des lecteurs et des bibliothèques de bandes 63Par exemple, si la solution de sauvegarde nécessite l'utilisation si

Strona 138 - 테이프 드라이브 및 라이브러리의 성능 고려사항

64 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comFigure 1-7. Ralentissement du débit des do

Strona 139

Remarques sur les performances des lecteurs et des bibliothèques de bandes 65Configurations de câblage recommandéesCâblage SCSI vers le système hôteBi

Strona 140

66 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comFigure 1-9. Câblage SCSI pour une biblioth

Strona 141

Remarques sur les performances des lecteurs et des bibliothèques de bandes 67Figure 1-10. Câblage reliant un pont Fibre Channel à un lecteur de bandeI

Strona 142

68 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comFigure 1-11. Câblage reliant un pont Fibre

Strona 143 - 드라이브를 Fibre Channel 브릿지에 연결

Remarques sur les performances des lecteurs et des bibliothèques de bandes 69Figure 1-12. Câblage reliant un pont Fibre Channel à trois lecteurs de ba

Strona 144 - 144 테이프 드라이브 및 라이브러리의 성능 고려사항

Performance Considerations for Tape Drives and Libraries 7General Hard Drive Configuration ConsiderationsData/operating system (OS) on different LUNs.

Strona 145

70 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comFigure 1-13. Câblage reliant un pont Fibre

Strona 146 - 146 테이프 드라이브 및 라이브러리의 성능 고려사항

Remarques sur les performances des lecteurs et des bibliothèques de bandes 71Figure 1-14. Paramètres de division en zones du canal pour une bibliothèq

Strona 147

72 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.comFigure 1-16. Câblage reliant un pont Fibre

Strona 148 - 148 테이프 드라이브 및 라이브러리의 성능 고려사항

Remarques sur les performances des lecteurs et des bibliothèques de bandes 73Les figures 1-18 et 1-19 indiquent comment configurer une bibliothèque co

Strona 149

74 Remarques sur les performances des lecteurs et des bibliothèques de bandeswww.dell.com | support.dell.com

Strona 150

www.dell.com | support.dell.comDell™ PowerVault™-SystemeHinweise zurLeistungsoptimierungbei Bandlaufwerkenund Bandbibliotheken

Strona 151 - Consideraciones sobre

____________________Irrtümer und technische Änderungen vorbehalten.© 2005 Dell Inc. Alle Rechte vorbehalten.Die Reproduktion dieses Dokuments in jegli

Strona 152

Inhalt 77InhaltEinführung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Allgemeine Datensicherungshinweise für Hostserv

Strona 153

78 Inhalt

Strona 154 - 154 Índice

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 79EinführungAngesichts der jüngsten Verbesserungen bei den Übertragungsraten

Strona 155 - Introducción

8 Performance Considerations for Tape Drives and Librarieswww.dell.com | support.dell.comRandom access time or seek time. Usually measured in millisec

Strona 156

80 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comPuffergröße der Datensicherungssoftware. Um

Strona 157

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 81So passt sich etwa das Bandlaufwerk Dell PowerVault 110T (LTO2 und LTO3) b

Strona 158

82 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comAbbildung 1-1. Single-Channel- vs. Two-Chan

Strona 159 - Información general de RAID

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 83Dieses Merkmal ist von entscheidender Bedeutung, wenn sich auf einem Festp

Strona 160

84 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comRAID 0RAID 0 ist auch unter der Bezeichnung

Strona 161

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 85RAID 1RAID 1 wird auch als „Mirroring“ bezeichnet. Bei dieser Konfiguratio

Strona 162

86 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comRAID 5Bei einem RAID-5-Array werden Daten i

Strona 163

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 87Insgesamt ist RAID 0 tendenziell die beste Konfiguration für maximale Lese

Strona 164 - Configuraciones SCSI

88 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comSAN-KonfigurationenFibre-Channel (FC) biete

Strona 165 - Configuraciones de SAN

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 89Wenn die Datensicherungslösung beispielsweise den gleichzeitigen Betrieb m

Strona 166

Performance Considerations for Tape Drives and Libraries 9RAID 0Commonly known as striping, RAID 0 allows two or more disks to be joined to create one

Strona 167

90 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comAbbildung 1-7. Datenübertragungs-Engpass vs

Strona 168

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 91Empfehlungen für die KabelkonfigurationSCSI-Kabelverbindung zum HostBandbi

Strona 169 - Terminador

92 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comDatensicherungsanwendung aktivieren, können

Strona 170

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 93Kabelkonfigurationen für Fibre-Channel-Brücke mit BandlaufwerkenDie Abbild

Strona 171

94 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comAbbildung 1-11. Kabelkonfiguration für Fibr

Strona 172

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 95Abbildung 1-12. Kabelkonfiguration für Fibre-Channel-Brücke mit drei Bandl

Strona 173

96 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comAbbildung 1-13. Kabelkonfiguration für Fibr

Strona 174

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 97Abbildung 1-15. Kabelkonfiguration für Fibre-Channel-Brücke mit fünf Bandl

Strona 175

98 Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliothekenwww.dell.com | support.dell.comAbbildung 1-16. Kabelkonfiguration für Fibr

Strona 176

Hinweise zur Leistungsoptimierung bei Bandlaufwerken und Bandbibliotheken 99Die Abbildungen 1-18 bis 1-19 zeigen, wie eine Bandbibliothek mit bis zu z