Dell OpenManage Server Administrator Version 6.0.1 Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Płyty główne Dell OpenManage Server Administrator Version 6.0.1. Dell OpenManage Server Administrator Version 6.0.1 CIM Reference Guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 140
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - CIM Reference Guide

www.dell.com | support.dell.comDell™ OpenManage™Server AdministratorCIM Reference Guide

Strona 2 - Notes and Cautions

10 Introduction• Added a new property — SystemSlotType to the CIM_Slot class.• Added new values for the UpgradeMethod and Family properties of the CIM

Strona 3 - Contents

100 Dell-Defined ClassesDELL_PostLogThe DELL_PostLog identified in Table 4-2 is a record of the system’s power-on self-test (POST). When you turn on a

Strona 4 - 4 Contents

Dell-Defined Classes 101DELL_CMDeviceThe DELL_CMDevice identified in Table 4-4 contains information related to the Dell Change Management device.Table

Strona 5

102 Dell-Defined ClassesDELL_CMDeviceApplicationThe DELL_CMDeviceApplication class identified in Table 4-5 contains information related to the Dell Ch

Strona 6 - 6 Contents

Dell-Defined Classes 103DELL_CMInventoryThe DELL_CMInventory identified in Table 4-6 contains information related to the Dell Change Management invent

Strona 7

104 Dell-Defined ClassesDELL_CMProductInfoThe DELL_CMProductInfo identified in Table 4-8 contains information related to the Dell Change Management pr

Strona 8 - 8 Contents

Dell-Defined Classes 105DELL_BIOSExtensionsThe DELL_BIOSExtensions identified in Table 4-9 contain information related to the specific extension of th

Strona 9 - Introduction

106 Dell-Defined ClassesManagement Object File For Change ManagementThis section shows the Management Object File (MOF) invcim.mof.#pragma classflags(

Strona 10 - Base Classes

Dell-Defined Classes 107 SupportsEnumeration = "TRUE";};instance of __MethodProviderRegistration{ Provider = $P;};//core.mof//========

Strona 11 - Parent Classes

108 Dell-Defined Classes[write (true), key: ToSubClass]string subVendorID;[write (true), key: ToSubClass]string bus;[write (true), key: ToSubClass]str

Strona 12 - Common Properties of Classes

Dell-Defined Classes 109{[write (true), key: ToSubClass]string name;[write (true), key: ToSubClass]string description;[write (true), key: ToSubClass]s

Strona 13

Introduction 11• DELL_CMInventory• DELL_CMOS• DELL_CMProductInfoThe CIM_ManagedSystemElement class is the base class for the system element hierarchy

Strona 14 - Other Documents You May Need

110 Dell-Defined Classes};[Dynamic, Provider ("omprov"),Description("The Dell_CMApplication class contains all the information related

Strona 15 - Typographical Conventions

Dell-Defined Classes 111Dell_CMDevice REF Antecedent; [key, Override ("Dependent"), Description ("The Application")

Strona 16 - 16 Introduction

112 Dell-Defined Classes [Override("UnitModifier") ]sint32 UnitModifier = -1; [Override("RateUnits") ]uint16 RateUnits =

Strona 17 - CIM_PhysicalElement

Dell-Defined Classes 113 [Override ("NormalMin"), MappingStrings {"MIF.DMTF|Electrical Current Probe|001.8"} ]sint

Strona 18 - 18 CIM_PhysicalElement

114 Dell-Defined Classes ]sint32 Tolerance; [Override ("Accuracy"), MappingStrings {"MIF.DMTF|Electrical Current Probe

Strona 19 - CIM_PhysicalPackage

Dell-Defined Classes 115sint32 UpperThresholdCritical; [Override ("LowerThresholdFatal"), MappingStrings {"MIF.DMTF|Electric

Strona 20 - CIM_PhysicalFrame

116 Dell-Defined Classes [Override("BaseUnits") ]uint16 BaseUnits = 7; [Override("UnitModifier") ]sint32 UnitModifier =

Strona 21 - CIM_Chassis

Dell-Defined Classes 117 ]sint32 NormalMax; [Override ("NormalMin"), MappingStrings {"MIF.DMTF|Electrical Current Probe

Strona 22 - DELL_Chassis

118 Dell-Defined Classes [Override ("Tolerance"), MappingStrings {"MIF.DMTF|Electrical Current Probe|001.18"} ]sin

Strona 23 - 2 - Unformatted

Dell-Defined Classes 119 [Override ("UpperThresholdCritical"), MappingStrings {"MIF.DMTF|Electrical Current Probe|001.14&quo

Strona 24 - CIM_Chip

12 IntroductionDell-Defined ClassesServer Administrator has extended some CIM classes and has created new classes to assist in managing systems and th

Strona 25

120 Dell-Defined Classesclass DELL_PowerConsumptionData : CIM_LogicalDevice {[Description ( "total power consumed from a start time")]uin

Strona 26 - CIM_PhysicalMemory

Dell-Defined Classes 121datetime parTime;[Description ( "Peak wattage reading")]unint16 peakWattReading;[Description ( "The time

Strona 27

122 Dell-Defined Classes// ==================================================[Association, Description ( "A PowerConsumptionAmpsSensor associated

Strona 28 - CIM_PhysicalConnector

Dell-Defined Classes 123 "A PowerConsumptionWattsSensor associated with a DELL_System which is defined by this class.")]class DELL_Ass

Strona 29

124 Dell-Defined Classes{ [Override ("Antecedent"), Description ("The DELL_System instance.") ]DELL_System REF Ant

Strona 30 - 30 CIM_PhysicalElement

Dell-Defined Classes 125 uint32 DellInstanceID; [read, Description ( "Enables or Disables the Trusted Platform Module (TPM)."), Displa

Strona 31 - CIM_Slot

126 Dell-Defined Classes

Strona 32 - 32 CIM_PhysicalElement

CIM_Dependency 127CIM_DependencyThe CIM_Dependency class is an association used to establish dependency relationships between two managed system eleme

Strona 33 - CIM_PhysicalElement 33

128 CIM_DependencyDELL_FanSensorThe DELL_FanSensor class described in Table 5-1 defines a Dell-specific association between a fan and a sensor. The CI

Strona 34 - 34 CIM_PhysicalElement

CIM_Dependency 129CIM_PackageVoltSensorThe CIM_PackageVoltSensor identified in Table 5-3 contains voltage sensors that are often installed in a packag

Strona 35 - CIM_LogicalElement

Introduction 13IsLinear Indicates that the sensor is linear over its dynamic range.BooleanManufacturer Provides the name of the organization responsib

Strona 36

130 CIM_DependencyCIM_PackageCurrentSensorThe CIM_PackageCurrentSensor shown in Table 5-4 contains amperage sensors that are often installed in a pack

Strona 37 - CIM_System

CIM_Dependency 131CIM_PackagePowerSupplySensorThe CIM_PackagePowerSupplySensor class described in Table 5-6 contains power supplies that provide power

Strona 38 - DELL_System

132 CIM_DependencyDELL_PackagePSRedundancyThe DELL_PackagePSRedundancy class listed in Table 5-7 defines what constitutes power supply redundancy for

Strona 39 - CIM_LogicalDevice

CIM_Dependency 133Table 5-8. DELL_PSRedundancy PropertiesClass Name: DELL_PSRedundancyParent Class: CIM_DependencyElement DescriptionAntecedent CIM_P

Strona 41

Glossary 135GlossaryThe following list defines or identifies technical terms, abbreviations, and acronyms used in user documents.asset tag codeAn indi

Strona 42 - CIM_NetworkPort

136 GlossarycomponentManageable components are operating systems, computer systems, expansion cards, or peripherals that are compatible with a systems

Strona 43

Glossary 137propertyA property is a capability or characteristic of a CIM class. The temperature probe class, for example, has a property that describ

Strona 44 - DELL_NetworkPort

138 GlossarySNMPAbbreviation for Simple Network Management Protocol. SNMP is an industry-standard interface that allows a network manager to remotely

Strona 45

Index 139IndexCCIM classes and properties, 10base classes, 10classes that describe relationships, 11common properties of classes, 12conventions, 12par

Strona 46 - 46 CIM_LogicalElement

14 IntroductionOther Documents You May NeedBesides this Dell OpenManage Server Administrator CIM Reference Guide, you can find the following guides ei

Strona 47 - CIM_Sensor

140 IndexCIM_PhysicalComponent, 24CIM_PhysicalElememtCIM_PhysicalConnector, 28CIM_PhysicalMemory, 26CIM_PhysicalElement, 17CIM_Chassis, 21CIM_Chip, 24

Strona 48 - 48 CIM_LogicalElement

Introduction 15•Dell OpenManage Installation and Security User’s Guide provides complete information on installation procedures and step-by-step instr

Strona 49 - CIM_NumericSensor

16 IntroductionTable 1-2. CIM_DMA PropertiesClass Name: CIM_DMAParent Class: CIM_SystemResourceProperty Description Data TypeDMAChannel A part of the

Strona 50 - 50 CIM_LogicalElement

CIM_PhysicalElement 17CIM_PhysicalElementCIM_PhysicalElement is a CIM-defined class. The CIM_PhysicalElement class contains the subclasses shown in Fi

Strona 51

18 CIM_PhysicalElementTable 2-1. CIM_PhysicalElement PropertiesClass Name: CIM_PhysicalElementParent Class: CIM_ManagedSystemElementProperty Descript

Strona 52 - CIM_TemperatureSensor

CIM_PhysicalElement 19CIM_PhysicalPackageThe CIM_PhysicalPackage class listed in Table 2-2 represents physical elements that contain or host other com

Strona 53 - CIM_CurrentSensor

Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potenti

Strona 54 - CIM_VoltageSensor

20 CIM_PhysicalElementCIM_PhysicalFrameThe CIM_PhysicalFrame class described in Table 2-3 contains other frame enclosures such as racks and chassis. P

Strona 55 - CIM_Tachometer

CIM_PhysicalElement 21CIM_ChassisThe CIM_Chassis class described in Table 2-4 represents the physical elements that enclose physical elements such as

Strona 56 - CIM_WatchDog

22 CIM_PhysicalElementDELL_ChassisThe DELL_Chassis class explained in Table 2-5 defines the identifying and status properties of the chassis. DELL_Cha

Strona 57 - CIM_CoolingDevice

CIM_PhysicalElement 23LogFormat Defines whether the event log data is unicode formatted or binary (raw). Values for the event LogFormat property are:1

Strona 58

24 CIM_PhysicalElementCIM_PhysicalComponentThe CIM_PhysicalComponent class listed in Table 2-6 represents any low-level or basic component within a pa

Strona 59 - CIM_PointingDevice

CIM_PhysicalElement 25Table 2-7. CIM_Chip PropertiesClass Name: CIM_ChipParent Class: CIM_PhysicalComponentProperty Description Data TypeFormFactor0

Strona 60 - 60 CIM_LogicalElement

26 CIM_PhysicalElementCIM_PhysicalMemoryThe CIM_PhysicalMemory class described in Table 2-8 is a subclass of CIM_Chip, representing low-level memory d

Strona 61 - CIM_Keyboard

CIM_PhysicalElement 27MemoryType (continued)11 - Flash12 - EEPROM13 - FEPROM14 - EPROM15 - CDRAM16 - 3DRAM17 - SDRAM18 - SGRAM19 - RDRAM20 - DDR21 - D

Strona 62 - CIM_PowerSupply

28 CIM_PhysicalElementCIM_PhysicalConnectorThe CIM_PhysicalConnector class explained in Table 2-9 includes physical elements such as plugs, jacks, or

Strona 63

CIM_PhysicalElement 29Table 2-9. CIM_PhysicalConnector PropertiesClass Name: CIM_PhysicalConnectorParent Class: CIM_PhysicalElementProperty Descripti

Strona 64 - CIM_Controller

Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . 9Server Administrator . . . . . . . . . . . . . . . . . . . 9Docu

Strona 65 - CIM_ParallelController

30 CIM_PhysicalElement11 - Fibre Channel (DB-9 Copper)41 - unused 71 - Bus Mouse 101 - unused12 - Fibre Channel (Fiber Optical)42 - unused 72 - ADB 10

Strona 66 - CIM_SerialController

CIM_PhysicalElement 31CIM_SlotThe CIM_Slot class described in Table 2-11 represents connectors into which packages are inserted. For example, a physic

Strona 67 - CIM_PCIController

32 CIM_PhysicalElementSystemSlotType Indicates the type of system slot. Values for the SystemSlotType property are as follows:OtherUnknownISAMCAEISAPC

Strona 68 - CIM_PCIDevice

CIM_PhysicalElement 33Contd.PCI Express x16PCI Express Gen 2PCI Express Gen 2 x1PCI Express Gen 2 x2PCI Express Gen 2 x4PCI Express Gen 2 x8PCI Expres

Strona 69 - CIM_PCIBridge

34 CIM_PhysicalElement

Strona 70 - CIM_Processor

CIM_LogicalElement 35CIM_LogicalElementCIM_LogicalElement is a CIM-defined class containing the subclasses shown in Figure 3-1.Figure 3-1. CIM_Logical

Strona 71

36 CIM_LogicalElementCIM_LogicalElementTable 3-1 lists the following characteristics for members of the CIM_LogicalElement class:• Represent abstracti

Strona 72 - 72 CIM_LogicalElement

CIM_LogicalElement 37CIM_SystemThe CIM_System class shown in Table 3-2 defines a collection of managed system elements that operates as a functional w

Strona 73

38 CIM_LogicalElementCIM_ComputerSystemThe CIM_ComputerSystem class listed in Table 3-3 contains some or all of the following CIM_ManagedSystemElement

Strona 74 - 74 CIM_LogicalElement

CIM_LogicalElement 39CIM_LogicalDeviceThe CIM_LogicalDevice class described in Table 3-5 models a hardware entity that may be realized in physical har

Strona 75

4 ContentsCIM_PhysicalMemory . . . . . . . . . . . . . . . . . . 26CIM_PhysicalConnector. . . . . . . . . . . . . . . . . 28CIM_Slot. . . . . . .

Strona 76 - 76 CIM_LogicalElement

40 CIM_LogicalElementCIM_FRUThe CIM_FRU class described in Table 3-6 contains manufacturing information related to the Field Replaceable Units (FRU) o

Strona 77

CIM_LogicalElement 41CIM_LogicalPortThe CIM_LogicalPort class listed in Table 3-7 represents the abstraction of a port or connection point of a device

Strona 78 - 78 CIM_LogicalElement

42 CIM_LogicalElementCIM_NetworkPortThe CIM_NetworkPort class listed in Table 3-8 describes the logical representation of a network. Table 3-8. CIM_Ne

Strona 79 - CIM_Memory

CIM_LogicalElement 43DELL_ManagedSystemServicesDeviceThe DELL_ManagedSystemServicesDevice class listed in Table 3-9 defines the type, size of storage

Strona 80 - CIM_CacheMemory

44 CIM_LogicalElementDELL_NetworkPortThe DELL_NetworkPort class listed in Table 3-10 represents the abstraction of a port or connection point of a dev

Strona 81

CIM_LogicalElement 45Table 3-10. DELL_NetworkPort PropertiesClass Name: Dell_NetworkPort Parent Class: CIM_NetworkPortProperty Description Data TypeN

Strona 82 - CIM_SoftwareElement

46 CIM_LogicalElementNiciSCSICapability Defines NIC Internet Small Computer System Interface (iSCSI) Capability. The following values, with explanatio

Strona 83

CIM_LogicalElement 47CIM_SensorThe CIM_Sensor class explained in Table 3-11 contains hardware devices capable of measuring the characteristics of some

Strona 84 - CIM_BIOSElement

48 CIM_LogicalElementTable 3-11. CIM_Sensor PropertiesClass Name: CIM_SensorParent Class: CIM_LogicalDeviceProperty Description Data TypeSensorType T

Strona 85 - CIM_SoftwareFeature

CIM_LogicalElement 49CIM_DiscreteSensorThe CIM_DiscreteSensor class described in Table 3-12 has a set of legal string values that it can report. The C

Strona 86 - CIM_SystemResource

Contents 5CIM_WatchDog . . . . . . . . . . . . . . . . . . . . . 56CIM_CoolingDevice. . . . . . . . . . . . . . . . . . . 57CIM_Fan. . . . . . . .

Strona 87

50 CIM_LogicalElementFigure 3-2. Ranges for Threshold ValuesTable 3-13 provides definitions for NumericSensor properties.Table 3-13. CIM_NumericSensor

Strona 88 - 88 CIM_LogicalElement

CIM_LogicalElement 51UpperThresholdNonCritical See Table 1-1. sint32LowerThresholdCritical See Table 1-1. sint32UpperThresholdCritical See Table 1-1.

Strona 89 - CIM_MemoryMappedIO

52 CIM_LogicalElementCIM_TemperatureSensorThe CIM_TemperatureSensor class listed in Table 3-14 contains sensors that sample ambient temperature and re

Strona 90

CIM_LogicalElement 53CIM_CurrentSensorThe CIM_CurrentSensor class listed in Table 3-15 contains sensors that measure amperage and returns a value in a

Strona 91 - CIM_RedundancyGroup

54 CIM_LogicalElementCIM_VoltageSensorThe CIM_VoltageSensor class shown in Table 3-16 contains sensors that measure voltage and return a value in volt

Strona 92 - CIM_ExtraCapacityGroup

CIM_LogicalElement 55CIM_TachometerThe CIM_Tachometer class listed in Table 3-17 contains devices that measure revolutions per minute (RPM) of a fan a

Strona 93 - DELL_PSRedundancyGroup

56 CIM_LogicalElementCIM_WatchDogThe CIM_WatchDog class described in Table 3-18 represents a timer that is implemented in system hardware. The watchdo

Strona 94 - DELL_FanRedundancyGroup

CIM_LogicalElement 57CIM_CoolingDeviceThe CIM_CoolingDevice class described in Table 3-19 contains a set of devices that work to keep the ambient inte

Strona 95 - CIM_RemoteServiceAccessPoint

58 CIM_LogicalElementCIM_FanThe CIM_Fan class explained in Table 3-20 contains a set of devices that work to keep the ambient internal temperature of

Strona 96 - 96 CIM_LogicalElement

CIM_LogicalElement 59CIM_UserDeviceThe CIM_UserDevice class shown in Table 3-21 contains logical devices that allow a computer system’s users to input

Strona 97

6 ContentsCIM_SystemResource . . . . . . . . . . . . . . . . . . 86CIM_IRQ. . . . . . . . . . . . . . . . . . . . . . . . . 87CIM_MemoryMappedIO.

Strona 98 - 98 CIM_LogicalElement

60 CIM_LogicalElementTable 3-22. CIM_PointingDevice PropertiesClass Name: CIM_PointingDeviceParent Class: CIM_UserDeviceProperty Description Data Typ

Strona 99

CIM_LogicalElement 61CIM_KeyboardThe CIM_Keyboard class explained in Table 3-23 includes devices that allow users to enter data.Table 3-23. CIM_Keyboa

Strona 100 - DELL_CMApplication

62 CIM_LogicalElementCIM_PowerSupplyThe CIM_PowerSupply class described in Table 3-24 contains devices that provide current and voltage for the operat

Strona 101 - DELL_CMDevice

CIM_LogicalElement 63ActiveInputVoltage Indicates which input voltage range is currently in use. Range 1, 2, or both can be specified using the values

Strona 102 - DELL_CMDeviceApplications

64 CIM_LogicalElementCIM_ControllerThe CIM_Controller class shown in Table 3-25 groups miscellaneous control-related devices. Examples of controllers

Strona 103 - DELL_CMOS

CIM_LogicalElement 65CIM_ParallelControllerThe CIM_ParallelController class identified in Table 3-26 contains a set of objects that control parallel d

Strona 104 - DELL_CMProductInfo

66 CIM_LogicalElementCIM_SerialControllerThe CIM_SerialController class explained in Table 3-27 contains controllers that transfer data one bit at a t

Strona 105 - DELL_BIOSExtensions

CIM_LogicalElement 67CIM_PCIControllerThe CIM_PCIController class listed in Table 3-28 contains a set of devices that follow the Peripheral Component

Strona 106 - Management

68 CIM_LogicalElementCIM_PCIDeviceThe CIM_PCIDevice class shown in Table 3-29 describes the capabilities and management of a PCI device controller on

Strona 107 - Dell-Defined Classes 107

CIM_LogicalElement 69CIM_PCIBridgeThe CIM_PCIBridge class shown in Table 3-30 describes the capabilities and management of a PCI controller providing

Strona 108 - Dell-Defined Classes

Contents 7DELL_BIOSExtensions . . . . . . . . . . . . . . . . . 105Management Object File For Change Management . . . . . . . . . . . . . . . . . .

Strona 109 - Dell-Defined Classes 109

70 CIM_LogicalElementCIM_ProcessorThe CIM_Processor class described in Table 3-31 contains devices that interpret and execute commands, for example, t

Strona 110

CIM_LogicalElement 71Table 3-31. CIM_Processor PropertiesClass Name: CIM_ProcessorParent Class: CIM_LogicalDeviceProperty Description Data Typ eRole

Strona 111 - Classes for Power Management

72 CIM_LogicalElementCoreEnabledCount Indicates the number of core processors enabled. uint16CurrentClockSpeed Indicates the current speed (in MHz) of

Strona 112

CIM_LogicalElement 73ExtendedStates Indicates the setting of the extended capabilities of the processor. This attribute is a bit field. The following

Strona 113 - Dell-Defined Classes 113

74 CIM_LogicalElementFamily Refers to the processor family type. Values for the Family property are as follows:1 - Other2 - Unknown3 - 80864 - 802865

Strona 114

CIM_LogicalElement 75Family (continued)29 - AMD Athlon™ Processor Family30 - AMD29000 Family31 - K6-2+32 - Power PC Family33 - Power PC 60134 - Power

Strona 115 - Dell-Defined Classes 115

76 CIM_LogicalElementFamily (continued)82 - microSPARC II83 - microSPARC IIep84 - UltraSPARC 85 - UltraSPARC II86 - UltraSPARC IIi87 - UltraSPARC III8

Strona 116

CIM_LogicalElement 77Family (continued)139 - Third-Generation AMD Opteron™ Processor Family144 - PA-RISC family145 - PA-RISC 8500146 - PA-RISC 8000147

Strona 117 - Dell-Defined Classes 117

78 CIM_LogicalElement189 - Intel Pentium Extreme Edition processor190 - Intel Core 2 processor200 - S/390 and zseries family201 - ESA/390 G4202 - ESA/

Strona 118

CIM_LogicalElement 79CIM_StorageExtentCIM_StorageExtent identified in Table 3-32 contains devices that manage data storage, for example, hard drives o

Strona 120

80 CIM_LogicalElementCIM_CacheMemoryThe CIM_CacheMemory class explained in Table 3-34 describes the capabilities and management of cache memory. Cache

Strona 121 - Dell-Defined Classes 121

CIM_LogicalElement 81WritePolicy Either defines whether this cache is a write-back or write-through cache or whether this information varies with addr

Strona 122

82 CIM_LogicalElementCIM_SoftwareElementThe CIM_SoftwareElement class described in Table 3-35 is used to define a CIM_SoftwareFeature. The CIM_Softwar

Strona 123 - Dell-Defined Classes 123

CIM_LogicalElement 83SoftwareElementType Indicates the type of software element. Values for SoftwareElementType are:1 - Other2 - Unknown3 - BIOS4 - ES

Strona 124

84 CIM_LogicalElementCIM_BIOSElementThe CIM_BIOSElement class listed in Table 3-36 describes the BIOS for the system. The BIOS controls the following:

Strona 125 - Dell-Defined Classes 125

CIM_LogicalElement 85CIM_SoftwareFeatureThe CIM_SoftwareFeature class shown in Table 3-37 defines a particular function or capability of a product or

Strona 126 - 126 Dell-Defined Classes

86 CIM_LogicalElementDELL_SoftwareFeatureDELL_SoftwareFeature described in Table 3-38 defines the universal resource locator (URL) of the systems mana

Strona 127 - CIM_Dependency

CIM_LogicalElement 87CIM_IRQThe CIM_IRQ class described in Table 3-40 contains IRQ information. An IRQ is a signal that data is about to be sent to or

Strona 128

88 CIM_LogicalElementAvailability Indicates the availability of the IRQ. Values for the Availability property are as follows:1 - Other2 - Unknown3 - A

Strona 129

CIM_LogicalElement 89CIM_MemoryMappedIOThe CIM_MemoryMappedIO class explained in Table 3-41 addresses both memory and port I/O resources for personal

Strona 130

Introduction 9IntroductionThis reference guide documents the Dell™ OpenManage™ Server Administrator Common Information Model (CIM) provider contained

Strona 131

90 CIM_LogicalElementCIM_DMAThe CIM_DMA class explained in Table 3-42 contains DMA information. A DMA channel allows certain types of data transfer be

Strona 132

CIM_LogicalElement 91CIM_RedundancyGroupThe CIM_RedundancyGroup class explained in Table 3-43 is a set of components that provide more instances of a

Strona 133

92 CIM_LogicalElementCIM_ExtraCapacityGroupThe CIM_ExtraCapacityGroup class explained in Table 3-44 applies to systems that have more capability and c

Strona 134 - 134 CIM_Dependency

CIM_LogicalElement 93DELL_PSRedundancyGroupThe DELL_PSRedundancyGroup described in Table 3-45 is a Dell-specific extension of the CIM_PowerSupply clas

Strona 135 - Glossary

94 CIM_LogicalElementDELL_FanRedundancyGroupThe DELL_FanRedundancyGroup described in Table 3-46 defines what constitutes fan redundancy in a system.CI

Strona 136

CIM_LogicalElement 95CIM_ServiceAccessPointThe CIM_ServiceAccessPointGroup class described in Table 3-48 represents the ability to utilize or invoke a

Strona 137 - Glossary 137

96 CIM_LogicalElementTable 3-49. CIM_RemoteServiceAccessPointGroup PropertiesClass Name: CIM_RemoteServiceAccessPointGroupParent Class: CIM_ServiceAc

Strona 138

CIM_LogicalElement 97DELL_RemoteServiceAccessPortThe DELL_RemoteServiceAccessPortGroup class described in Table 3-50 is an extended class of the CIM_R

Strona 139 - Index 139

98 CIM_LogicalElement

Strona 140

Dell-Defined Classes 99Dell-Defined ClassesThe Dell-defined classes are defined and populated by Dell™ rather than by CIM. None of these classes have

Komentarze do niniejszej Instrukcji

Brak uwag