706 Traps
Amperage Probe Failure
1204 Current sensor detected a failure value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete: Current
sensor value (in Amps): <Reading>
If sensor type is discrete: Discrete
current state: <State>
Error A current sensor on the
power supply for the
specified system
exceeded its failure
threshold. The sensor
location, chassis
location, previous state,
and current sensor
value are provided.
Amperage Probe Non-recoverable
1205 Current sensor detected a
non-recoverable value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete: Current
sensor value (in Amps): <Reading>
If sensor type is discrete: Discrete
current state: <State>
Error A current sensor in the
specified system
detected an error from
which it cannot recover.
The sensor location,
chassis location,
previous state, and
current sensor value are
provided.
Table 27-6. Amperage Probe Traps
(continued)
TrapID Description Severity Cause
book.book Page 706 Tuesday, February 28, 2012 2:19 PM