16
Fixed problems
EMC AX4-5 Series Integrated Management Software Release Notes
Platforms Brief description Symptom details
Solution (or
workaround)
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
AX4-5SCF4
AX4-5F8
FLARE Operating
Environment
When a zone configuration is
disabled, storage systems
affected by the zone change
may experience storage
processor bugchecks
(0x01901057, 0x000000d1).
28121930/219399
Frequency of occurrence
:
Rarely under a rare set of
circumstances.
Severity
:
Critical
When a zone configuration
is disabled, storage
systems affected by the
zone change may
experience storage
processor bugchecks
(0x01901057,
0x000000d1).
KnowledgeBase ID
:
None
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
02.23.050.5.705
Fixed in version
:
02.23.050.5.707
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
AX4-5SCF4
AX4-5F8
FLARE Operating
Environment
Following a change to its World
Wide Name (WWN) seed, a
storage system may experience
repeated storage processor
bugchecks (0x0000007E).
29307940/225249
Frequency of occurrence
:
Always under a rare set of
circumstances.
Severity
:
Critical
Following a change to the
World Wide Name (WWN)
seed, a storage system
may experience repeated
storage processor
bugchecks if one of the
storage processors
reboots for any reason
before the change is fully
processed, (0x0000007E).
KnowledgeBase ID
:
None
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
02.23.050.5.705
Fixed in version
:
02.23.050.5.707
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
AX4-5SCF4
AX4-5F8
FLARE Operating
Environment
While a storage processor is
rebooting, a single storage
processor bugcheck
(0x030n2017) may occur.
30368840/232306
Frequency of occurrence
:
Rarely under a specific set of
circumstances
Severity
:
Medium
On an iSCSI connected
storage system, a single
storage processor
bugcheck (0x030n2017)
may occur if the host
aborts an I/O while a
storage processor is
rebooting.
KnowledgeBase ID
:
None
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
02.23.050.5.705
Fixed in version
:
02.23.050.5.707
Przeglądanie stron 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 46 47

Komentarze do niniejszej Instrukcji

Brak uwag