Table 6. Expected translations.
Client location Service Tag location Does OpenManage
Integration for
VMware vCenter
support client
locale?
Can OpenManage
Integration for
VMware vCenter
show pages in client
locale language?
OpenManage
Integration for
VMware vCenter
shows pages in
default English
1 Location A Location A Yes Yes No
2 Location A Location B No No Yes
3 Location A Location B Yes No Yes
4 Location A Location B Yes No Yes
5 Location A Location A No No Yes
Use this following example.
Table 7. Example
Client location Service Tag location Does OpenManage
Integration for
VMware vCenter
support client
locale?
Can OpenManage
Integration for
VMware vCenter
show pages in client
locale language?
OpenManage
Integration for
VMware vCenter
shows pages in
default English
1 France France Yes Yes No
2 Brazil China No No Yes
3 Germany China Yes No Yes
4 China Brazil Yes No Yes
5 India India No No Yes
How come I do not see my new iDRAC version details listed on the vCenter Hosts &
Clusters page?
After the successful completion of a firmware update task in the vSphere Web client’s recent tasks pane, refresh the
Firmware Update page and verify the firmware versions. If the page shows the old versions, then go to Host Compliance
page in OpenManage Integration for VMware vCenter and check the CISOR status of that host. If CISOR is not enabled,
then enable CISOR and reboot host. If the CISOR was already enabled, then login to the iDRAC console, reset iDRAC,
wait for few minutes, and then refresh the Firmware Update page in vSphere Web client.
NOTE: The host compliance is not available in the web client and you would have to use the host compliance
feature from the vSphere Desktop client
How Do I Test Event Settings by Using OMSA to Simulate a Temperature Hardware Fault?
To make sure that events are functioning correctly:
1. In the OMSA user interface, navigate to Alert Management → Platform Events.
2. Select the Enable Platform Event Filter Alerts check box.
3. Scroll down to the bottom, and click Apply Changes.
4. To make sure that a specific event is enabled, such as temperature warning, from the tree on the left, select Main
System Chassis.
5. Under Main System Chassis, select Temperatures.
172