Przeglądanie stron 23
Dell
Dell PowerEdge R310 Technical Guide 23
Figure 13. Redundant PSU Fan Configuration (5 Fans)
Additional details regarding the fans for the R310 include:
The Embedded Server Management logic in the system will control and monitor the speed of the fans. A
fan failure or over-temperature in the system will result in a notification from iDRAC6.
The R310 power supply units do not have any integrated fans; they are cooled by the system fan in front
of them. The system requires a PSU blank (metal cover) in place of the empty power supply slot.
System fan speed is pulse-width modulated.
Fans are non-redundant and not hot-swappable.
4.12 Cabling