Dell OpenManage Server Administrator Version 7.4 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Kontrolery RAID Dell OpenManage Server Administrator Version 7.4. Dell OpenManage Server Administrator Version 7.4 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1

Server Administrator Storage Management

Strona 2 - Copyright

Assigning A Dedicated Hot Spare...177Unassigning A Dedica

Strona 3 - Contents

• Based on the minimum (and even) number of physical disks selection the firmware on the PERC 9 hardware controller recommends the preferred span layo

Strona 4

• When you create a virtual disk using the Advanced Wizard, you can select the physical disk sector from the Sector Size drop-down list. The options a

Strona 5

• Create Virtual Disk Express Wizard• Create Virtual Disk Advanced WizardHot Spare Considerations — T10 Protection Information CapabilityThe following

Strona 6

10Enclosures And BackplanesPhysical disks can be contained in an enclosure or attached to the backplane of a system. An enclosure is attached to the s

Strona 7

• Enclosure And Backplane Health• Enclosure And Backplane Properties And TasksSMART Thermal ShutdownDoes my enclosure support this feature? See Suppor

Strona 8

Table 22. Fan PropertiesProperty DefinitionStatus These icons represent the severity or health of the storage component. — Normal/OK — Warning/Non-cri

Strona 9

Property Definition — Warning/Non-critical — Critical/Failure/ErrorFor more information, see Storage Component Severity.Name Displays the name of the

Strona 10

To Launch The Set Temperature Probe WizardTo launch the Set Temperature Probe wizard:1. In the Server Administrator window, under the system tree, exp

Strona 11

Property Definition• Minimum Warning Threshold Exceeded—The temperature of the enclosure has dropped below the minimum warning threshold.• Maximum War

Strona 12

To verify the EMM firmware version:1. In the Server Administrator window, under the system tree, click Storage dashboard.2. Expand the tree view until

Strona 13

Cables Attached Correctly...193System Requireme

Strona 14

Property DefinitionFirmware Version Indicates the version of the firmware loaded on the EMM. All EMM modules in the enclosure should have the same le

Strona 15 - Overview

Property DefinitionNOTE: If the enclosure is connected to the controller in redundant path mode (for more information, see Setting The Redundant Path

Strona 16 - Supported Controllers

Property Definitiondifferent modes, see the enclosure hardware documentation.The bus configuration switch when toggled on a 220S or 221S enclosure, th

Strona 17 - Supported Enclosures

7. Click Execute.Enclosure — Available TasksThe drop-down menu enclosure tasks are:• Enabling The Enclosure Alarm• Disabling The Enclosure Alarm• Sett

Strona 18

To Locate Set Asset Data In Storage ManagementTo locate this task in storage management:1. In the Server Administrator window, under the system tree,

Strona 19 - Getting Started

Changing The Warning Threshold On The Temperature ProbeThe temperature probes are listed in the Temperature Probes section. To change the temperature

Strona 20 - User Privileges

Changing The Mode On 220S And 221S EnclosuresMake sure that you turn off the enclosure before you toggle the bus configuration switch on a 220S or 221

Strona 21 - Common Storage Tasks

Enclosure ComponentsFor information on attached components, see:• Physical Disk Or Physical Device Properties• EMM Properties• Fan Properties• Power S

Strona 23 - Understanding RAID Concepts

11ConnectorsA controller contains one or more connectors (channels or ports) to which you can attach disks. You can externally access a connector by a

Strona 24 - Performance

On H310 I do not see any option for Fluid Cache...202Cannot add more than 64 VDs for

Strona 25 - Concatenation

3. Click Exit Wizard to cancel the virtual disk creation. In this step, you select the channels and the disks to be used by the virtual disk. The sele

Strona 26 - RAID Level 0 (Striping)

The connector properties can vary depending on the model of the controller. Connector properties may include:Table 27. Connector PropertiesProperty De

Strona 27 - RAID Level 1 (Mirroring)

On a SCSI controller, the Rescan task rescans the controller connectors to verify the currently connected devices or to recognize new devices that hav

Strona 28

Property Definition• Failed — The connector has encountered a failure and is no longer functioning.Connector Type Displays whether the connector is o

Strona 30

12Tape DriveTape drives contain several tape backup units (TBUs) on which data can be backed up. Storage Management enumerates the TBUs that are used

Strona 32

13RAID Controller BatteriesSome RAID controllers have batteries. If the controller has a battery, Storage Management displays the battery under the co

Strona 33

Property Definition• Auto — Storage Management performs an automatic learn cycle based on the set time.• Warn — The learn cycle is past the default 90

Strona 34

The learn cycle recalibrates the battery-integrated circuit so that the controller can determine whether the battery can maintain the controller cache

Strona 35 - Hot Spare Protection Policy

Connector Tasks Supported On The SAS 5/iR, SAS 6/iR, And H200 Controllers... 234Physical Disk Tasks Supported On The SAS 5/iR, SAS 6/

Strona 36 - Storage Component Severity

To Locate Delay Learn Cycle In Storage ManagementTo locate this task in Storage Management:1. In the Server Administrator window, under the system tre

Strona 37 - Alerts Or Events

14Physical Disks Or Physical DevicesPhysical disks or physical devices reside within an enclosure or are attached to the controller. On a RAID control

Strona 38

4. Click Execute.The new disk is displayed in the tree view after the rescan. If the new disk is not displayed, restart the system.For SAS Controllers

Strona 39 - PCIe SSD SubSystem Properties

Disk Is Not Part Of A Redundant Virtual Disk1. Back up data from the virtual disk.2. Delete the virtual disk.3. Replace the disk that is receiving SMA

Strona 40 - PCIe Extender Cards

Property DefinitionTransition Indicates that the physical drive is changing from the spun down state to spun up state.Spun Up Indicates that the physi

Strona 41 - Physical Device Properties

Property Definitionbe returned to a usable state by performing a Format, Initialize, Slow, And Fast Initialize task. If the Format, Initialize, Slow,

Strona 42

Property DefinitionYou may also want to review the alert log to see whether the physical disk or device has generated alerts pertaining to a SMART pre

Strona 43 - Physical Device Tasks

Property DefinitionNOTE: This option is applicable to Micron PCIe SSDs, Non-Volatile Memory Express (NVMe) PCIe SSDs, and SAS/SATA SSDs.Used RAID Disk

Strona 44 - Exporting The Log

Property DefinitionPCIe Negotiated Link Width Displays the current negotiated link width of the physical device.Physical Disk Or Physical Device Tasks

Strona 45 - PCIe SSD

NOTE: The Blink and Unblink tasks are only supported for hotswap physical disks (disks that reside in a carrier). When using an LSI PCI-e U320 control

Strona 46

Health Status Rollup: Lost Both Power Connections To The Enclosure... 253Health Status Rollup: One Or More Physica

Strona 47 - PCIe SSD SubSystem Health

NOTE: Rebuilding a disk may take several hours.Related LinksReplacing A Failed Disk That Is Part Of A Redundant Virtual DiskCanceling A RebuildDoes my

Strona 48

Considerations For Hot Spares On PERC S100 And PERC S300 ControllersGlobal Hot Spare Considerations On A SAS 6/iRSetting The Physical Disk Online Or O

Strona 49

Considerations For Slow InitializeTo Locate Clear In Storage ManagementTo locate this task in storage management:1. In the Server Administrator window

Strona 50 - Fluid Cache Disks

CAUTION: Instant Encrypt Erase permanently erases all data present on the disk.Select the Instant Encrypt Erase task to erase an encrypted physical di

Strona 52

15Virtual DisksA virtual disk refers to a storage created by a RAID controller from one or more physical disks. Although a virtual disk may be created

Strona 53 - Cache I/O Statistics

• PERC 5/E and PERC 5/I• PERC 6/E and PERC 6/I• PERC H310 Adapter, PERC H310 Mini Monolithic, and PERC H310 Mini Blades• PERC H700, PERC H710 Adapter,

Strona 54 - License Settings

to expand the virtual disk, or create new virtual disks in the unused space. The virtual disks have identical RAID level.Also, existing mixed configur

Strona 55

For information about the maximum number of physical disks supported by a virtual disk, see the virtual disk specifications for the controller in Supp

Strona 56

Before creating a virtual disk, you should be familiar with the information in Considerations Before Creating Virtual Disks.Storage Management provide

Strona 57 - Global Tasks

1OverviewServer Administrator Storage Management provides enhanced features for configuring the locally attached RAID and non-RAID disk storage on a s

Strona 58 - Storage Controller Properties

Controller Starting RAID Level Target RAID Level CommentsPERC 5/E and PERC 5/i RAID 1 RAID 0 With or without adding additional disksRAID 1 RAID 5 Add

Strona 59

Choosing RAID Levels And ConcatenationMaintaining The Integrity Of Redundant Virtual DisksDoes my controller support this feature? See Supported Featu

Strona 60

Table 33. Sample Scenarios For Virtual Disk Bad BlocksRAID Level Virtual Disk State Scenario ResultRAID 0 Degraded One bad block on a physical disk.Th

Strona 61

RAID Level Virtual Disk State Scenario Resultlocation. The problem is resolved.Recommendations For Clearing Bad BlocksStorage Management allows you to

Strona 62 - RAID Controller Features

Property Definition — Normal/OK — Warning/Non-critical — Critical/Failure/ErrorFor more information, see Storage Component Severity.Name Displays the

Strona 63 - Write Policy

Property DefinitionEncrypted Displays whether the virtual disk is encrypted. The possible values are Yes and No.Hot Spare Policy Violated Displays whe

Strona 64 - Disk Cache Policy

Property DefinitionWrite Policy Displays the write policy that the controller is using for the selected virtual disk. See RAID Controller Read, Write,

Strona 65 - Non-RAID SAS Controllers

• Changing The Virtual Disk Policy• Replacing A Member Disk• Clearing Virtual Disk Bad Blocks• Encrypting A Virtual DiskReconfiguring A Virtual DiskDo

Strona 66 - Firmware Or Driver Versions

Deleting Data On the Virtual DiskDoes my controller support this feature? See Supported Features.The Delete task destroys all data on the virtual disk

Strona 67 - Controller Health

Canceling A RebuildDoes my controller support this feature? See Supported Features.Select the Cancel Rebuild task to cancel a rebuild that is in progr

Strona 68

• Added support for Software RAID controllers (PERC S110) on systems running the Windows Server 2012 R2 operating system.• Added support for Non-Volat

Strona 69

• Have an Encryption Key• Have Self Encryption Drives (SEDs) virtual disksCreate Virtual Disk Express WizardDoes my controller support this feature? S

Strona 70

5. Select the Express Wizard option and the RAID level from the drop-down list.– Depending on the controller, Concatenated enables you to combine the

Strona 71 - Controller Tasks

selected physical disk. The default values of the virtual disk attributes excluding the RAID level are recommended for the selected RAID level.1. In t

Strona 72 - Enabling The Controller Alarm

4. Click Go to the Create Virtual Disk Wizard.The Create Virtual Disk Wizard (Step 1) <Controller Name> page is displayed.5. Select the Advanced

Strona 73 - Setting The Rebuild Rate

7. Select the required RAID level from the drop-down list.– Depending on the controller, Concatenated enables you to combine the storage capacity of s

Strona 74

NOTE: It is recommended that you use Intelligent Mirroring to create RAID 10 across enclosures for simple and optimum configuration.NOTE: To view the

Strona 75

• Physical disk 0:4Physical Disks SelectedThe Physical Disks Selected section of the page displays the disks you have chosen. In this example, two dis

Strona 76

Policy and the selected physical disk. The default values of the virtual disk attributes excluding the RAID level are recommended for the selected RAI

Strona 77

5. Click Finish to complete the virtual disk creation.The virtual disk is displayed in the Virtual Disk(s) on Controller <Controller Name> page.

Strona 78

NOTE: You cannot reconfigure a virtual disk on a controller that is operating in cluster mode.NOTE: You can create no more than 64 virtual disks on a

Strona 79

• PERC H200 Adapter, PERC H200 Integrated, and PERC H200 Modular• PERC H800 Adapter, PERC H700 Adapter, PERC H700 Integrated, and PERC H700 Modular• P

Strona 80

Channel Redundancy And Thermal ShutdownTo locate Reconfigure In Storage Management1. In the Server Administrator window, under the system tree, expand

Strona 81

To Reconfigure a Virtual Disk (Changing the RAID Level and Size): Step 2 of 31. Select the new RAID level for the virtual disk — The available RAID le

Strona 82

The virtual disk reconfigure step 3 page enables you to review your changes before completing the virtual disk reconfiguration.1. Review your changes.

Strona 83

NOTE: RAID 6 and RAID 60 virtual disks which are T10 PI enabled do not support Slow Initialize.Related LinksFormat, Initialize, Slow, And Fast Initial

Strona 84 - Setting The Reconstruct Rate

To Delete A Virtual DiskTo identify which physical disks are included in the virtual disk, click Blink. The LED lights on the physical disks blink for

Strona 85

To Locate Rename In Storage ManagementTo locate this task in storage management:1. In the Server Administrator window, under the system tree, expand S

Strona 86 - Setting The Patrol Read Mode

CAUTION: Your virtual disk is longer redundant after performing a Split Mirror operation.To Locate Split Mirror In Storage Management 1. In the Server

Strona 87 - To Set The Patrol Read Mode

A dedicated hot spare is an unused backup disk that is assigned to a single virtual disk. When a physical disk in the virtual disk fails, the hot spar

Strona 88

You can copy data from a physical disk, which is a member of a virtual disk, to another physical disk by providing a Replace Member Configuration opti

Strona 89

To Replace a Member Disk: Step 2 of 21. Review your changes. The source Physical Disk table displays details of the source physical disk. The destinat

Strona 91 - Managing The Preserved Cache

6. Click Execute.A pop-up window is displayed confirming the disable operation.Any dirty data for the virtual disk is moved from the cache to the virt

Strona 92 - Encryption Key

16Moving Physical And Virtual Disks From One System To AnotherThis section describes how to move physical and virtual disks from one system to another

Strona 93 - Managing The Encryption Key

5. Use the Foreign Configuration Operations task to import the migrated virtual disks on the receiving controller.NOTE: The Foreign Configuration Oper

Strona 94 - Converting To Non-RAID Disks

17Protecting Your Virtual Disk With A Hot SpareWhen you create a virtual disk using a RAID controller, it enables the system to continue functioning e

Strona 95 - Viewing Available Reports

Dedicated Hot Spare Protection PolicyTable 35. Hot Spare PropertiesProperty DefinitionRAID Level Indicates the RAID level(s) for which you want to con

Strona 96 - Viewing Slot Occupancy Report

• For SAS/iR and PERC H200 family of controllers, you can assign only two global hot spares.• If the status of the virtual disk is displayed as Degrad

Strona 97

In this case, you can unassign the global hot spare after creating a new virtual disk and then assign a new and larger hot spare to cover all redundan

Strona 98

To ensure that the controller firmware always has a healthy physical disk as a global hot spare:• Unassign the hot spare that is assigned as a global

Strona 100

18CacheCade Using Solid-State DrivesCacheCade is used to improve random read performance of the solid-state drive (SSD) based virtual disks. A solid-s

Strona 101

2Getting StartedServer Administrator Storage Management is designed for system administrators who implement hardware RAID solutions and understand cor

Strona 102

The CacheCade(s) page is displayed.1. In the Server Administrator window, under the System tree, expand Storage.2. Click a storage controller. For exa

Strona 103 - Enclosures And Backplanes

3. Type a name for the CacheCade. The size is calculated as follows:CacheCade size = capacity of the smallest SSD * the number of SSDs4. From the avai

Strona 105 - Enclosure Power Supplies

19TroubleshootingThis section contains troubleshooting procedures for common situations as well as for specific problems.Related LinksCommon Troublesh

Strona 106 - Enclosure Temperature Probes

Drivers And FirmwareStorage Management is tested with the supported controller firmware and drivers. In order to function properly, the controller mus

Strona 107

Rebuilding DataReplacing The DiskTo replace the failed disk that is part of a redundant virtual disk:1. Remove the failed disk.2. Insert a new disk. M

Strona 108

Setting The Physical Disk Online Or OfflineRecovering From Removing The Wrong Physical DiskIf the physical disk that you mistakenly removed is part of

Strona 109 - EMM Properties

• The hot spare has been unassigned from the virtual disk — This occurs on some controllers if the hot spare is assigned to more than one virtual disk

Strona 110

Management is only able to recognize extremely small virtual disks if they are dynamic. It is advisable to create virtual disks of larger size when us

Strona 111

Physical Disk Is Offline Or Displays An Error StatusA physical disk may display an error status if it has been damaged, is offline, or was a member of

Strona 112 - Enclosure And Backplane Tasks

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Strona 113 - Enclosure — Available Tasks

https://<localhost>:1311where <localhost> is the assigned name for the managed system and 1311 is the default port.orhttps://<IP addres

Strona 114

Alerts 2146 Through 2150 Received While Performing I/O, Consistency Check, Format, Or Other OperationIf you receive alerts 2146 through 2150 while per

Strona 115 - View Slot Occupancy Report

Storage Management May Delay Displaying Storage Devices After RebootStorage Management requires time after a reboot to find and inventory all attached

Strona 116 - Enclosure Management

• Peripheral Component Interconnect Express (PCIe) Solid-State Drive (SSD) Is Not Visible In The Operating System• PCIe SSD Is Not Visible In Disk Man

Strona 117 - Enclosure Components

Configured mode vs operational mode troubleshooting in cases of Pass Through and Write Through operational mode.When the last but one PCIe SSD is remo

Strona 119 - Connectors

20Frequently Asked QuestionsThis section provides frequently asked questions that address situations commonly experienced in a storage environment.• W

Strona 120 - Connector Health

Replacing A Physical Disk Receiving SMART AlertsHow Do I Recover From Removing The Wrong Physical DiskFor more information, see Recovering From Removi

Strona 121 - Rescanning The Connector

Which RAID Level Is Best For Me?For more information, see Choosing RAID Levels And Concatenation and Comparing RAID Level And Concatenation Performanc

Strona 123 - Connector Components

21Supported FeaturesDifferent controllers support different features. The tasks displayed by the Storage Management menus and other features vary depe

Strona 124

Using The Storage Management Command-Line InterfaceStorage Management has a fully featured command-line interface (CLI). For more information on CLI,

Strona 125 - Tape Drive

Controller Task NamePERC 5/E PERC 5/I PERC 6/E PERC 6/I PERC 6/I ModularTest Alarm Yes No No NA NAReset ConfigurationYes Yes Yes Yes YesSet Rebuild Ra

Strona 126

Controller Task NamePERC 5/E PERC 5/I PERC 6/E PERC 6/I PERC 6/I ModularImport Preview of Foreign ConfigurationNo No Yes with firmware 6.1 and laterYe

Strona 127 - RAID Controller Batteries

Battery Task NamePERC 5/E PERC 5/i PERC 6/E PERC 6/I PERC 6/I ModularDelay Learn Cycle Yes Yes Yes Yes YesConnector Tasks Supported By The PERC 5/ And

Strona 128 - Battery — Available Tasks

Virtual Disk Tasks Supported By The PERC 5/ And PERC 6/ ControllersTable 42. Virtual Disk Tasks Supported by the PERC 5/ and PERC 6/ ControllersVirtua

Strona 129 - Delay The Battery Learn Cycle

Virtual Disk Task NamePERC 5/E PERC 5/I PERC 6/E PERC 6/I PERC 6/I ModularFormat Virtual DiskNo No No No NoCancel Format Virtual Disk No No No No NoRe

Strona 130

Virtual Disk SpecificationPERC 5/E PERC 5/I PERC 6/E PERC 6/I PERC 6/I ModularPhysical Disks per SpanMinimum Stripe Size 8 K 8 K 8 K 8 K 8 KMaximum St

Strona 131

Virtual Disk SpecificationPERC 5/E PERC 5/I PERC 6/E PERC 6/I PERC 6/I ModularMinimum Number of Physical Disks in a RAID 0 1 1 1 1 1Minimum Number of

Strona 132 - For SAS Controllers

RAID Levels Supported By The PERC 5/E And PERC 6 ControllersTable 44. RAID Levels Supported by the PERC 5/E and PERC 6/ ControllersRAID Level PERC 5/E

Strona 133 - Other Disk Procedures

Read, Write, and Cache PolicyPERC 5/E PERC 5/I PERC 6/E PERC 6/I PERC 6/I ModularWrite Cache Enabled ProtectedNo No No No NoCache Policy No No No No N

Strona 134

For enclosure-supported tasks, see Enclosure And Backplane Features.Controller Tasks Supported On The PERC Hardware ControllersTable 47. Controller Ta

Strona 136

Controller Task NamePERC H800PERC H810 AdapterPERC H700 Adapter/IntegratedPERC H700 ModularPERC H710 Adapter/ Mini Monolithic/Mini BladePERC H710P Ada

Strona 137

Controller Task NamePERC H800PERC H810 AdapterPERC H700 Adapter/IntegratedPERC H700 ModularPERC H710 Adapter/ Mini Monolithic/Mini BladePERC H710P Ada

Strona 138 - Physical Disk Tasks

Battery Tasks Supported On The PERC Hardware ControllersTable 48. Battery Tasks Supported on the PERC Hardware ControllersBattery Task NamePERC H800PE

Strona 139 - Rebuilding Data

Physical Disk Tasks Supported By The PERC Hardware ControllersTable 50. Physical Disk Tasks Supported by the PERC Hardware ControllersPhysical Disk Ta

Strona 140 - Canceling A Rebuild

Physical Disk Task NamePERC H800PERC H810 AdapterPERC H700 Adapter/IntegratedPERC H700 ModularPERC H710 Adapter/Mini Blade/Mini MonolithicPERC H710P A

Strona 141

Virtual Disk Task NamePERC H800PERC H810 AdapterPERC H700 Adapter/Integrated/ModularPERC H710 Adapter/Mini Monolithic/Mini BladePERC H710P Adapter/Min

Strona 142 - Enabling Revertible Hot Spare

Virtual Disk Task NamePERC H800PERC H810 AdapterPERC H700 Adapter/Integrated/ModularPERC H710 Adapter/Mini Monolithic/Mini BladePERC H710P Adapter/Min

Strona 143 - Convert To Non-RAID Disk

Virtual Disk SpecificationPERC H800PERC H810 AdapterPERC H700 Adapter/Integrated/ModularPERC H710 Mini BladePERC H710 Adapter/Mini MonolithicPERC H710

Strona 144

Virtual Disk SpecificationPERC H800PERC H810 AdapterPERC H700 Adapter/Integrated/ModularPERC H710 Mini BladePERC H710 Adapter/Mini MonolithicPERC H710

Strona 145 - Virtual Disks

Virtual Disk SpecificationPERC H800PERC H810 AdapterPERC H700 Adapter/Integrated/ModularPERC H710 Mini BladePERC H710 Adapter/Mini MonolithicPERC H710

Strona 146

3Understanding RAID ConceptsStorage Management uses the Redundant Array of Independent Disks (RAID) technology to provide Storage Management capabilit

Strona 147

Virtual Disk SpecificationPERC H800PERC H810 AdapterPERC H700 Adapter/Integrated/ModularPERC H710 Mini BladePERC H710 Adapter/Mini MonolithicPERC H710

Strona 148 - Creating Virtual Disks

RAID Levels Supported By The PERC Hardware ControllersTable 53. RAID Levels Supported by the PERC Hardware ControllersRAID LevelPERC H800PERC H810 Ada

Strona 149

Read, Write, and Cache PolicyPERC H800PERC H810 AdapterPERC H700 Adapter/Integrated/ModularPERC H710 Adapter/Mini Monolithic/Mini BladePERC H710P Adap

Strona 150

Supported Features On The SAS 5iR, SAS 6iR, And PERC H200 ControllersThis section identifies the controller-supported features and whether an enclosur

Strona 151

Controller Task NameSAS 5/iR SAS 6/iR PERC H200Import/Recover Foreign Configuration No Yes YesSet Patrol Read Mode No No NoStart Patrol Read No No N

Strona 152

Physical Disk Task NameSAS 5/IR SAS 6/iR PERC H200backplane and LEDs on the physical disks are present.Assign and Unassign Global Hot Spare No Support

Strona 153 - Virtual Disk Properties

Virtual Disk Task Name SAS 5/IR SAS 6/iR PERC H200Split Mirror No No NoUnmirror No No NoDelete Last Virtual Disk No Yes YesDelete (any) Virtual Disk

Strona 154

Virtual Disk Specifications For The SAS 5/iR, SAS 6/iR, And PERC H200 ControllersTable 62. Virtual Disk Specifications for the SAS 5/iR, SAS 6/iR, and

Strona 155

Virtual Disk Specification SAS 5/IR SAS 6/iR PERC H200Minimum Number of Physical Disks in a RAID 5 NA NA NAMinimum Number of Physical Disks in a RAID

Strona 156 - Virtual Disk Tasks

Read, Write, and Cache PolicySAS 5/IR SAS 6/iR PERC H200Cache Policy No No NoDisk Cache Policy Yes Yes YesCache I/O No No NoDirect I/O No No NoEnc

Strona 157 - Restoring Dead Segments

RAID ConceptsRAID uses particular techniques for writing data to disks. These techniques enable RAID to provide data redundancy or better performance.

Strona 158

Physical Disk Tasks Supported By The PERC S100, PERC S110, And S300 ControllersTable 66. Physical Disk Tasks Supported by the PERC S100, PERC S110, an

Strona 159 - Encrypting A Virtual Disk

Virtual Disk Specifications For The PERC S100, PERC S110, And S300 ControllersTable 68. Virtual Disk Specifications for the PERC S100, PERC S110, and

Strona 160

Virtual Disk Specification PERC S100 PERC S110 PERC S300Minimum Number of Physical Disks in a RAID 10 4 4 4RAID Levels Supported By The PERC S100, PER

Strona 161

Read, Write, and Cache PolicyPERC S100 PERC S110 PERC S300Disk Cache Policy No No NoCache I/O No No NoDirect I/O No No NoEnclosure Support On The P

Strona 162

Controller Task Name Non-RAID SCSI Non-RAID SASRescan Controller No NoCreate Virtual Disk No NoExport Log File No NoClear Foreign Configuration No

Strona 163

Physical Disk Task Name Non-RAID SCSI Non-RAID SASRebuild No NoCancel Rebuild No NoRemove Dead Disk Segments No NoFormat Disk No NoClear No NoCance

Strona 164

Virtual Disk Task Name Non-RAID SCSI Non-RAID SASRestore Dead Disk Segments No NoInitialize Virtual Disk No NoFast Initialize Virtual Disk No NoSlow I

Strona 165

Enclosure Tasks MD1000 StorageMD1120 MD1200 StorageMD1220Controller ReportsSlot Occupancy Report Yes Yes Yes YesMaximum Supported Configuration For S

Strona 167

22Determining The Health Status For Storage ComponentsThe chapter describes how the status of lower-level storage components is “rolled up" into

Strona 168 - Span Edit

volumes, availability or fault-tolerance is achieved by maintaining redundant data. Redundant data includes mirrors (duplicate data) and parity inform

Strona 169

Health Status Rollup: Physical Disks In A Virtual Disk Are Unsupported, Partially, Or Permanently DegradedTable 82. Health Status Rollup: Physical Dis

Strona 170

Health Status Rollup: Virtual Disk Is Degraded; Physical Disks Are Failed Or RebuildingTable 85. Health Status Rollup: Virtual Disk is Degraded; Physi

Strona 171

Health Status Rollup: Enclosure Power Supply Failed Or Power Connection RemovedTable 88. Health Status Rollup: Enclosure Power Supply Failed or Power

Strona 172 - Slow And Fast Initialize

Health Status Rollup: One Enclosure Temperature Probe Is FailedTable 91. Health Status Rollup: One Enclosure Temperature Probe is FailedStorage Subsys

Strona 173 - Deleting A Virtual Disk

Health Status Rollup: Physical Disk Is RebuildingTable 94. Health Status Rollup: Physical Disk is RebuildingStorage SubsystemController Connector Encl

Strona 174 - Renaming A Virtual Disk

When a physical disk in a concatenated or spanned volume fails, the entire volume becomes unavailable. Because the data is not redundant, it cannot be

Strona 175 - Split Mirror

RAID 0 characteristics:• Groups n disks as one large virtual disk with a capacity of (smallest disk size) *n disks.• Data is stored to the disks alter

Strona 176 - Unmirror

RAID 1 characteristics:• Groups n + n disks as one virtual disk with the capacity of n disks. The controllers currently supported by Storage Managemen

Strona 177

The additional parity provides data protection in the event of two disk failures. In the following image, the two sets of parity information are ident

Strona 178

Contents1 Overview...15What Is New In

Strona 179

RAID 50 characteristics:• Groups n*s disks as one large virtual disk with a capacity of s*(n-1) disks, where s is the number of spans and n is the num

Strona 180

RAID 60 characteristics:• Groups n*s disks as one large virtual disk with a capacity of s*(n-2) disks, where s is the number of spans and n is the num

Strona 181 - One System To Another

RAID 10 characteristics:• Groups n disks as one large virtual disk with a capacity of (n/2) disks, where n is an even integer.• Mirror images of the d

Strona 182

Comparing RAID Level And Concatenation PerformanceThe following table compares the performance characteristics associated with the more common RAID le

Strona 183 - Understanding Hot Spares

RAID Level Data AvailabilityRead PerformanceWrite PerformanceRebuild PerformanceMinimum Disks RequiredSuggested UsesRAID 5 Good Sequential reads: good

Strona 184

4Quick Access To Storage Status And TasksThis section describes various methods to determine the status or health of the storage components on your sy

Strona 185

After you set the number of assigned hot spares, any deviation from the protection policy threshold triggers an alert based on the severity level you

Strona 186 - S300 Controllers

• Physical Disk Or Physical Device Properties• Physical Disk Or Physical Device Tasks• EMM Properties• Fan Properties• Power Supply Properties• Temper

Strona 187

storage configuration, such as adding or removing physical disks from a virtual disk or changing a RAID level.You can rescan a controller object to:•

Strona 188

5PCI Express Solid-State Device SupportThis section provides an overview of the Storage Management device management support for Peripheral Component

Strona 190 - Creating A CacheCade

Properties Descriptionomreportcommand. For information on Command Line Interface, see the Server Administrator Command Line Interface User's Guid

Strona 191 - Deleting The CacheCade

Physical Device PropertiesYou can view information about PCIe SSDs and run PCIe SSD tasks on the Physical Device Properties page. To view the complete

Strona 192

Properties Descriptionexceeded and the warranty for the drive expires. The warranty coverage for the drive expires if the value for percent lifetime u

Strona 193 - Troubleshooting

Properties DescriptionPCIe Maximum Link Speed Displays the capable transfer speed of the physical device in GT/s.Fluid Cache Pool Member Indicates whe

Strona 194 - Replacing A Failed Disk

• Unconfigured SED drive• Foreign configured encrypted drives• Unconfigured and foreign SED drive even when an Encryption Key is not present in the co

Strona 195 - Assigning A Hot Spare

Enabling Cryptographic Erase On An Non-Volatile Memory Express (NVMe) PCIe SSDDoes my controller support this feature? See Supported Features.NOTE: Af

Strona 196 - Virtual Disk Troubleshooting

Adding PCIe SSDs To Fluid Cache PoolYou can configure or increase the capacity of the Fluid Cache pool by adding PCIe SSDs.To add a PCIe SSD to a cach

Strona 197 - Cannot Create A Virtual Disk

7. Click OK.Once the device removal is initiated from the cache pool, any dirty data is moved to the back-end disk. While the data migration is in pro

Strona 199 - Is Degraded

6Fluid Cache For DAS Fluid Cache is a server-side caching accelerator that makes high-speed Express Flash (PCIeSSD) a shared, distributed resource. Fl

Strona 200

License Settings...547

Strona 201 - PCIe SSD Troubleshooting

Properties Description• CriticalLicense StateDisplays the status of the Fluid Cache license. The possible options are:• Valid License• ExpiredFluid Ca

Strona 202 - Fluid Cache For DAS

Properties DescriptionConfigured Cache ModeDisplays the configured cache mode for the Fluid Cache disk. Possible values are:• Write Back• Write Throug

Strona 203

Table 9. Physical Device PropertiesProperties DescriptionID Displays the physical device ID as reported by the omreport CLI command.Status Displays th

Strona 204

Properties DescriptionModel Number Displays the model number of the physical device.Capacity Displays the capacity of the physical device.Vendor ID Di

Strona 205 - Frequently Asked Questions

In the Read/Write Bytes per Second for Fluid Cache Disk graph, the performance of cache read, cache write, disk read and disk write for the specified

Strona 206 - How Do I Turn Off An Alarm

Click Exit Wizard to go back to the Information Configuration page.55

Strona 208

7Storage Information And Global TasksUse the Storage information and Global Tasks window to view high-level information about the storage components o

Strona 209 - Supported Features

NOTE: Global Rescan is not supported on non-RAID controllers. You must reboot the system before Storage Management can display the configuration chang

Strona 210

Property DefinitionName Displays the name of the controller. For more detailed information on a controller, click its name on the controller name.Slot

Strona 211

Importing Foreign Configurations...78Importing Or Recover

Strona 212

Property Definitionfailed disk when a rebuild is necessary. For more information on rebuild rate, see Setting The Rebuild Rate.Alarm State Displays wh

Strona 213

8ControllersThis chapter provides information about the supported controllers and controller features in Storage Management.Related LinksRAID Controll

Strona 214

• PERC 6/E• PERC 6/I controller family• SAS 6/iR controller family• PERC S100, S110, and S300 controllers• PERC H200, H700, and H800 controllers• PERC

Strona 215

Controller — Supported Stripe SizesWhen creating a virtual disk, you must specify the stripe size for the virtual disk. Different controllers have dif

Strona 216

NOTE: Storage Management does not allow you to select the Write Back policy for controllers that do not have a battery. The only exceptions are PERC S

Strona 217 - Controllers

The cache policies are:• Enabled — Disk Cache Policy is enabled.• Disabled — Disk Cache Policy is disabled.NOTE: The default setting for Disk Cache Po

Strona 218

• LSI SAS 9300-8e• LSI SAS 9206-16eFirmware Or Driver VersionsUse the firmware or driver versions window to view information about the controller firm

Strona 219

Property DefinitionNOTE: To download the latest storport driver, see the Microsoft Knowledge Base article KB943545 at support.microsoft.com.Controller

Strona 220

Property Definition• — Critical/Failure/ErrorID Displays the ID assigned to the controller by Storage Management. Storage Management numbers the con

Strona 221

Property Definitioninitialization of a virtual disk after it is created. For more information on BGI rate, see Setting Background Initialization Rate.

Strona 222

Enclosure And Backplane Properties And Tasks... 110Changing The Mode On 220S And

Strona 223

Property DefinitionCache Memory Size Displays the size of the cache memory on the controller.Patrol Read Mode Displays the Patrol Read Mode setting

Strona 224

Property DefinitionAvailable Reports Enables you to view patrol read report, check consistency report, slot occupancy report, and physical disk firmwa

Strona 225

• Changing The Controller Properties• Managing The Physical Disk Power• Managing The Encryption Key• Converting To RAID Capable Disks• Converting To N

Strona 226

Select the Disable Alarm task to disable the alarm on the controller. When disabled, the alarm does not sound in the event of a device failure.Turning

Strona 227

To locate Set Rebuild Rate In Storage Management1. Expand the Storage tree object to display the controller objects.2. Select a controller object.3. C

Strona 228

The Export Log task exports the controller log to a text file. This log provides detailed information on the controller activities and can be useful f

Strona 229

The Foreign Configuration Preview page provides a preview of the foreign disks and enables you to perform operations such as, importing, recovering, o

Strona 230

Property Definition• Failed — The foreign disk has encountered a failure and is no longer functioning. You cannot import the foreign configuration.The

Strona 231

3. Click Information/Configuration on the controller Properties page.4. Select Foreign Configuration Operations from the Controller Tasks drop-down me

Strona 232

To Locate Import Or Recover Foreign Configuration In Storage ManagementFor SAS controllers with firmware versions 6.1 and later:1. In the Server Admin

Strona 233 - H200 Controllers

Other Disk Procedures...133Physical

Strona 234

For SAS controllers with firmware version 6.0 and earlier, select Clear Foreign Configuration from the Controller Tasks drop-down menu.Physical Disks

Strona 235

Property Definition• 2108• 2109• 2110• 2111For information on alert messages, see the Server Administrator Messages Reference Guide.Progress Displays

Strona 236

Property DefinitionPCIe Negotiated Link SpeedDisplays the current negotiated transfer speed of the physical device in GT/s.PCIe Maximum Link SpeedDisp

Strona 237

At 100%, the background initialization is the highest priority for the controller. The background initialization time is minimized and has the most im

Strona 238

3. Click Information/Configuration on the controller Properties page.4. Select Set Check Consistency Rate from the Available Tasks drop-down menu.5. C

Strona 239

redundant path is removed. The redundant path ceases to appear only when it is cleared in the storage management.In a daisy-chain scenario, more than

Strona 240

Table 19. Path between Enclosure n and Enclosure n +1Health of Logical Connector Path between Enclosure n and Enclosure n +1Connector 0 (C0) Connector

Strona 241

• The physical disk is included in a virtual disk that is currently undergoing one of the following:– Rebuild– Reconfiguration or reconstruction– Back

Strona 242 - S110, And S300 Controllers

To exit without starting or stopping the Patrol Read, click Go Back to Previous Page.Related LinksSetting The Patrol Read ModeLocate Start Stop Patrol

Strona 243

To Locate Change Controller Properties In Storage Management: Method 21. In the Server Administrator window, under the system tree, expand Storage to

Strona 244

Performing A Check Consistency...158Canceling A Check Cons

Strona 245

Table 20. Manage Physical Disk Power PropertiesProperty DefinitionSpin Down Unconfigured Drives The Enabled option spins down the unconfigured disks i

Strona 246

Managing The Physical Disk PowerManaging Physical Disk Power Using The QoS OptionTo manage physical disk power through the QoS option:1. Select the Cu

Strona 247

CAUTION: You may not be able to use Storage Management to manage the preserved cache in some cases. As an example, consider you have a RAID 1 level wi

Strona 248

4. If you want to save the Encryption Key credentials in a file on the system where Distributed Web Server is running, select the Escrow check box.The

Strona 249 - Storage Components

On an encryption-capable controller, the Manage Encryption Key task allows you to enable encryption in LKM mode. If you enable LKM, you can create an

Strona 250

3. Click Information/Configuration on the controller Properties page.4. In the controller tasks drop-down menu select the task Convert to RAID Capable

Strona 251 - Not Included)

Performing A Check ConsistencyTo Locate View Check Consistency Report In Storage Management1. In the Server Administrator window, under the system tre

Strona 252 - Power Connection Removed

Table 21. Physical Disk Firmware Version Report PropertiesProperty DefinitionName Displays the nexus or location of each drive that has to be updated

Strona 253

Property Definitionto stop or at least slow I/O operations during a DUP online firmware upgrade.Part Number In the event of a drive failure, you can

Strona 254

9Support For PERC 9 Hardware ControllersThe Dell PowerEdge RAID Controller (PERC) family of enterprise-class controllers is designed for enhanced perf

Komentarze do niniejszej Instrukcji

Brak uwag