Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Instrukcja Użytkownika Strona 277

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 276
Moving Physical and Virtual Disks from One System to
14
Moving Physical and Virtual Disks
from One System to Another
This section describes how to move physical and virtual disks from one
system to another.
Required Conditions
This section applies to PERC 4/SC, 4/DC, 4e/DC, 4/Di, PERC 5/E and PERC 5/i, and
SAS 5/iR Controllers
After some planning and preparation, it is possible to migrate physical and
virtual disks from one controller, enclosure or server to another. You can
perform physical and virtual disk migration on PERC 4/SC, 4/DC, 4e/DC,
4/Di, PERC 5/E and PERC 5/i, and SAS 5/iR controllers as long as the
following conditions are met.
General Conditions for SCSI and SAS Controllers
Virtual disks can only be migrated to a controller that is using the same
technology. For example, virtual disks on a SCSI controller must be
migrated to a SCSI controller and virtual disks on a SAS controller must be
migrated to a SAS controller. For more information, see RAID Controller
Technology: SCSI, SATA, ATA, and SAS.
When moving an enclosure, both SCSI and SAS controllers require that
you power down the enclosure and the server before moving the enclosure.
SCSI Controller Conditions
PERC 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, and 4e/Di virtual disks cannot be
migrated to a PERC 2/SC or PERC 2/DC controller. PERC 2/SC and
PERC 2/DC virtual disks can be migrated to a PERC 4/SC, 4/DC, 4e/DC,
4/Di, 4e/Si, or 4e/Di controller.
NOTE: The current version of Storage Management does not support the PERC 2,
2/Si, 2/SC, or 2/DC controllers.
Przeglądanie stron 276
1 2 ... 272 273 274 275 276 277 278 279 280 281 282 ... 389 390

Komentarze do niniejszej Instrukcji

Brak uwag