Dell OpenManage Server Administrator Version 6.0.1 Podręcznik Użytkownika Strona 707

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 780
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 706
Traps 707
RAC Traps
This section describes the traps that are generated by the SNMP agent of the
Remote Access Controller (RAC). All of the enterprise-specific traps documented
in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in
the section "Traps". The trap variables are sent in the order in which they are listed.
Battery Failure
1704 Battery sensor detected
a failure value
Sensor Location:
<Location in chassis>
Chassis Location: <Name
of chassis>
Previous state was:
<State>
Battery sensor status:
<status>
Critical A battery sensor in the
specified system detected
that a battery has failed.
The sensor location,
chassis location, previous
state, and battery sensor
status are provided.
Table 26-17. Generic Traps
Trap
ID
Name Description Severity Category Cause Supported
by RAC
Platform
0CodeStartSNMP agent
is
initializing
itself
Information Status RAC power
on or reset.
All
1 Authentic
ation
Failure
Request
received
with an
invalid
community
name
Critical Error SNMP
request
with an
invalid
community
name.
All
Table 26-16. Battery Traps (continued)
Trap ID Description Severity Cause
book.book Page 707 Tuesday, January 27, 2009 12:37 PM