Ok : Memory
Ok : Power Supplies
Ok : Temperatures
Ok : Voltages
Omreport Chassis Acswitch Or Omreport Mainsystem Acswitch
Use the omreport chassis acswitch or omreport mainsystem acswitch command if the system has redundant AC power
lines that are configured in a failover arrangement. Type:
omreport chassis acswitch
or
omreport mainsystem acswitch
Server Administrator displays the following output:
AC Failover Switch
AC Switch Redundancy
Redundancy Status : Full
Number of devices required
for full redundancy
: 2
Redundancy Mode :
Redundancy Configuration : Input Source Line 1, upon redundancy
restoration, return to Line 1
AC Power Lines
Status : Ok
Location : AC Power Line 1
AC Present : Power Present
Active Source : Active
Status : Ok
Location : AC Power Line 2
AC Present : Power Present
Active Source : Not Active
Server Administrator reports values for the
Redundancy Status and Redundancy Mode fields.