PowerEdge R515 Technical Guide The PowerEdge R515 offers enterprise-class features and superior price for performance.
Dell 10 PowerEdge R515 Technical Guide Feature R510 R515 (8 HDD) R515 (12 HDD) R710 Power Supplies 4-HDD chassis: non-redundant, 480W (80+ SILVER) 8-
Dell 11 PowerEdge R515 Technical Guide 2 System Overview Table 2. Product Features Summary Feature Technical Specification Form Factor 2U rack Proce
Dell 12 PowerEdge R515 Technical Guide Feature Technical Specification Communications Optional add-in NICs: Intel® 10GBase-T Copper Single Port NIC, P
Dell 13 PowerEdge R515 Technical Guide Feature Technical Specification Operating Systems Microsoft® Windows® Small Business Server 2008 Microsoft® Win
Dell 14 PowerEdge R515 Technical Guide 3 Mechanical 3.1 Chassis Description PowerEdge R515 chassis is a 2U rack-mount design that supports the follo
Dell 15 PowerEdge R515 Technical Guide 3.3 Front Panel View and Features The PowerEdge R515 is available in two chassis configurations: 8 hard drive
Dell 16 PowerEdge R515 Technical Guide Figure 5. Back View See the Back-Panel Features and Indicators section in the About Your System chapter of th
Dell 17 PowerEdge R515 Technical Guide Figure 7. Right Side View 3.8 Rails and Cable Management 3.8.1 ReadyRails Sliding Rails ReadyRailsTM Sliding
Dell 18 PowerEdge R515 Technical Guide Figure 8. R515 Mounted in B3 Sliding Rails Figure 9. Back View of R515 Mounted in B3 Sliding Rails with CM
Dell 19 PowerEdge R515 Technical Guide 3.11 Control Panel/LCD The PowerEdge R515 includes one of the following control panel configurations: LCD pa
Dell ii PowerEdge R515 Technical Guide This document is for informational purposes only. Dell reserves the right to make changes without further noti
Dell 20 PowerEdge R515 Technical Guide 3.11.2 LED Panel Configuration Figure 13 and Figure 14 show the LCD panel configuration for the PowerEdge R515
Dell 21 PowerEdge R515 Technical Guide 3.12.4 TPM The TPM is used to generate/store keys, protect/authenticate passwords, and create/store digital ce
Dell 22 PowerEdge R515 Technical Guide For detailed information on replacing parts for the PowerEdge R515, see the Installing System Components chapte
Dell 23 PowerEdge R515 Technical Guide 4 Power, Thermal, Acoustic 4.1 Power Supplies The PowerEdge R515 system is powered by hot-plug redundant 750
Dell 24 PowerEdge R515 Technical Guide Table 4. 750W Power Supply Specifications AC Power Supply (per power supply) Wattage 750W (optional redundant)
Dell 25 PowerEdge R515 Technical Guide Altitude Operating -15.2 to 10,668m (-50 to 35,000ft) Note: For altitudes above 2950 feet, the maximum operatin
Dell 26 PowerEdge R515 Technical Guide Max. Configuration @ 23 ± 2 °C Operating Mode LWA-UL (Bels) LpA (dBA) Prominent Tones CPU HDD RAID DIMM 2 x AM
Dell 27 PowerEdge R515 Technical Guide 5 Processors 5.1 Overview The PowerEdge R515 utilizes the latest four and six core offerings from AMD’s Opte
Dell 28 PowerEdge R515 Technical Guide 5.4 Processor Configurations The PowerEdge R515 is a two-socket server that will operate with either a single p
Dell 29 PowerEdge R515 Technical Guide 6 Memory 6.1 Overview The PowerEdge R515 utilizes DDR3 memory providing a high-performance, high-speed memory
Dell iii PowerEdge R515 Technical Guide Table of Contents 1 Product Comparison ...
Dell 30 PowerEdge R515 Technical Guide The following is not supported: Mixing of RDIMMs and UDIMMs Use of non-ECC UDIMMs For more information on
Dell 31 PowerEdge R515 Technical Guide System Capacity DIMM Slots 1 Socket Channel A Channel B UDIMM RDIMM A1 A3 A2 A4 DIMM speed System speed DIMM sp
Dell 32 PowerEdge R515 Technical Guide 7 Chipset 7.1 Overview The PowerEdge R515 planar uses a dual IOB configuration using the AMD SR5670 chipset wi
Dell 33 PowerEdge R515 Technical Guide 8 BIOS 8.1 Overview The PowerEdge R515 BIOS is based on the Dell BIOS core and supports the following feature
Dell 34 PowerEdge R515 Technical Guide 8.2 Supported ACPI States The following ACPI states are supported: ACPI compliance: S0, S4, S5 NO S1, S2,
Dell 35 PowerEdge R515 Technical Guide Feature Type Enable/Status/ Ctrl bit location Description Power Button Fixed PCH In ACPI mode, OS has control o
Dell 36 PowerEdge R515 Technical Guide Profile Description Custom CPU Power and Performance Management: Maximum Performance, Minimum Power, OS DBPM,
Dell 37 PowerEdge R515 Technical Guide 9 Embedded NICs/LAN on Motherboard (LOM) The Broadcom® 5716 LOM chip is located on the PowerEdge R515 motherbo
Dell 38 PowerEdge R515 Technical Guide 10 I/O Slots 10.1 Overview The PowerEdge R515 includes a total of three PCIe slots and one dedicated internal s
Dell 39 PowerEdge R515 Technical Guide 10.4 PCI Card Dimensions For information about PCIe slots and card dimensions, see the Back-Panel Features and
Dell iv PowerEdge R515 Technical Guide 5.3 Supported Processors ... 27
Dell 40 PowerEdge R515 Technical Guide 11 Storage 11.1 Overview There are two chassis types for the PowerEdge R515: 8 hard drive chassis: 8 x hot-
Dell 41 PowerEdge R515 Technical Guide Table 18. RAID Configurations (12 HDD Chassis) Factory Configuration No Mixed HDD (must be all 2.5" or
Dell 42 PowerEdge R515 Technical Guide Table 19. RAID Configurations (12 HDD Chassis, 12 + 2 HDDs) (12 + 2 HDD) Factory Configuration No Mixed HDD
Dell 43 PowerEdge R515 Technical Guide by the disk drive during normal operation. The bicolor LED is controlled by the SEP device on the backplane. Bo
Dell 44 PowerEdge R515 Technical Guide 12 Video The PowerEdge R515 is equipped with a Matrox® G200eW with 8MB memory integrated in the Nuvoton® WPCM45
Dell 45 PowerEdge R515 Technical Guide 13 Rack Information 13.1 Overview The ReadyRails™ sliding and static rail systems for the R515 provide toolless
Dell 46 PowerEdge R515 Technical Guide The adapter brackets kit includes 6 brackets to accommodate different rail lengths, plus four sets of custom sc
Dell 47 PowerEdge R515 Technical Guide One key factor in selecting the proper rails is identifying the type of rack in which they will be installed. B
Dell 48 PowerEdge R515 Technical Guide Hook-and-loop straps are utilized (rather than plastic tie wraps) to eliminate the risk of cable damage duri
Dell 49 PowerEdge R515 Technical Guide 14 Operating Systems and Virtualization For detailed information, see the following: • Operating System Suppor
Dell v PowerEdge R515 Technical Guide 15.1 Overview/Description ... 50
Dell 50 PowerEdge R515 Technical Guide 15 Systems Management 15.1 Overview/Description Dell aims on delivering open, flexible, and integrated solution
Dell 51 PowerEdge R515 Technical Guide Remote Access Controller) is responsible for acting as an interface between the host system and its management
Dell 52 PowerEdge R515 Technical Guide • Server Sensor monitoring and fault alerting • Secure operation of remote access functions including authen
Dell 53 PowerEdge R515 Technical Guide Feature BMC iDRAC6 Express iDRAC6 Enterprise vFlash Media Security and Authentication Role-based Authority
Dell 54 PowerEdge R515 Technical Guide 16 USB Peripherals The PowerEdge R515 supports the following USB devices: USB key (bootable) Keyboard (on
Dell 55 PowerEdge R515 Technical Guide Appendix A. Statement of Volatility The Dell PowerEdge R515 contains both volatile and non-volatile (NV) compo
Dell 56 PowerEdge R515 Technical Guide LOM (LAN [Network Interface] on Motherboard) Memory Details Size: 4Mb (1MB) Type: [e.g., Flash PROM, EEPROM
Dell 57 PowerEdge R515 Technical Guide TPM (Trusted Platform Module; For boards shipped outside of China; Boards sold to destinations in China do not
Dell 58 PowerEdge R515 Technical Guide Embedded Bootable Memory Device Details Size: 1GB Type: [e.g., Flash PROM, EEPROM]: MMC Can user programs or op
Dell 59 PowerEdge R515 Technical Guide Appendix B. Certifications B.1 Regulatory Certifications Regulatory models: E12S (8 HDD chassis) E13S
Dell vi PowerEdge R515 Technical Guide Figures Figure 1. R515 Chassis Dimensions ...
Dell 60 PowerEdge R515 Technical Guide Country/Region Authority or Mark Ukraine UKRTEST or UKRSERTCOMPUTER United States NRTL Uzbekistan STZ B.3 El
Dell 61 PowerEdge R515 Technical Guide B.4 Ergonomics, Acoustics and Hygienics The product has been certified and bears the Mark, as applicable, of t
Dell 62 PowerEdge R515 Technical Guide Appendix C. Additional Information and Options The PowerEdge R515 system conforms to the industry standards de
Dell 63 PowerEdge R515 Technical Guide Standard URL for information and specifications UEFI Unified Extensible Firmware Interface Specification, v2.1
Dell 7 PowerEdge R515 Technical Guide 1 Product Comparison 1.1 Overview The Dell™ PowerEdge™ R515 is a 2-socket 2U rack server well-suited for databa
Dell 8 PowerEdge R515 Technical Guide The optional Lifecycle Controller helps you perform system diagnostics, hardware configuration, and system deplo
Dell 9 PowerEdge R515 Technical Guide Feature R510 R515 (8 HDD) R515 (12 HDD) R710 Ext Drive Bay(s) 1 for slim optical drive in 4-HDD and 8-HDD chassi