fusionIoDimmInfoBeacon
Writing a true value here will
turn on the LED flashing beacon
for visual card identification. A
false value will turn the LED
fusionIoDimmInfoPCIAddress
Device address on the PCI bus
fusionIoDimmInfoPCIDeviceID
fusionIoDimmInfoPCISubdeviceID
fusionIoDimmInfoPCIVendorID
fusionIoDimmInfoPCISubvendorID
fusionIoDimmInfoPCISlot
fusionIoDimmInfoWearoutIndicator
True = device has surpassed
the wearout threshold.
fusionIoDimmInfoFlashbackIndicator
for driver 2.3.1 and earlier)
True = flashback redundancy is
degraded.
fusionIoDimmInfoWritableIndicator
0 = Write-reduced; 1= non-
writable (read-only); 2=normal;
fusionIoDimmInfoInternalTemp
Current internal temperature of
the device in degrees Celsius
fusionIoDimmInfoHealthPercentage
Estimate of the health of the
drive expressed as the
remaining percentage of drive
life before write rate is reduced
due to wearout. If the health
percentage is not available, the
fusionIoDimmInfoShortTermWearoutDate
fusionIoDimmInfoLongTermWearoutDate
fusionIoDimmInfoShortTermNonWritableDate
fusionIoDimmInfoLongTermNonWritable Date
fusionIoDimmInfoMinimalModeReason
Reason the device is in minimal
mode:
0=unknown; 1=firmware out of
date; 2=low power; 3=dual-
plane mode failed; 5=internal
error; 6=card limit exceeded;
7=device not in minimal mode;
8=unsupported OS;
89
Komentarze do niniejszej Instrukcji