Command
Modes
Auto
Command
History
Version 9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
The authenticator completes authentication only when port-control is set to
auto.
dot1x quiet-period
Set the number of seconds that the authenticator remains quiet after a failed authentication with a client.
Syntax
dot1x quiet-period seconds
To disable quiet time, use the no dot1x quiet-time command.
Parameters
seconds Enter the number of seconds. The range is from 1 to 65535.
The default is 60.
Defaults 60 seconds
Command
Modes
INTERFACE
Command
History
Version 9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
dot1x reauthentication
Enable periodic reauthentication of the client.
Syntax
dot1x reauthentication [interval seconds]
To disable periodic reauthentication, use the no dot1x reauthentication
command.
Parameters
interval
seconds
(Optional) Enter the keyword interval then the interval
time, in seconds, after which reauthentication is initiated.
The range is from 1 to 31536000 (one year). The default is
3600 (1 hour).
Defaults 3600 seconds (1 hour)
Command
Modes
INTERFACE
132
802.1X
Komentarze do niniejszej Instrukcji