22 Event Message Reference
Current Sensor Messages
Current sensors listed in Table 2-5 measure the amount of current (in amperes) that is traversing critical
components. Current sensor messages provide status and warning information for current sensors in a
particular chassis.
1155 Voltage sensor detected a
non-recoverable value
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
If sensor type is not discrete:
Voltage sensor value (in Volts):
<Reading>
If sensor type is discrete:
Discrete voltage state:
<State>
Error A voltage sensor in the specified
system detected an error from
which it cannot recover. The
sensor location, chassis location,
previous state, and voltage
sensor value are provided.
Table 2-5. Current Sensor Messages
Event ID Description Severity Cause
1200 Current sensor has failed
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading>
If sensor type is discrete:
Discrete current state:
<State>
Information A current sensor on the power
supply for the specified system
failed. The sensor location,
chassis location, previous state,
and current sensor value
are provided.
Table 2-4. Voltage Sensor Messages (continued)