Any number of SSDs can be added to a CacheCade virtual disk.
There is no SAS and SATA mixing allowed within a CacheCade virtual disk, so SATA SSDs cannot be added to a
SAS CacheCade virtual disk and vice versa.
HDDs cannot be added to a CacheCade virtual disk.
NOTE: Capacity of drives added to a CacheCade volume must be equal to or greater than the smallest
contributing drive in the virtual disk. The manual resizing of a CacheCade virtual disk cannot be initiated in
the BIOS Configuration Utility. It can only be initiated in the OpenManage storage management application.