26 About Your Solution
E141F CPU # protocol
error. Power
cycle AC.
The system BIOS
has reported a processor
protocol error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 113.
E1420 CPU Bus parity
error. Power
cycle AC.
The system BIOS has
reported a processor bus
parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 113.
E1422 CPU # machine
check error.
Power
cycle AC.
The system BIOS has
reported a machine
check error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 113.
E1610 Power Supply #
(### W)
missing.
Check power
supply.
Specified power supply
was removed or is missing
from the system.
See "Troubleshooting
Power Supply" on
page 96.
E1614 Power Supply #
(### W) error.
Check power
supply.
Specified power supply
has failed.
See "Troubleshooting
Power Supply" on
page 96.
E1618 Predictive
failure on
Power Supply #
(### W).
Check PSU.
An over-temperature
condition or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
See "Troubleshooting
Power Supply" on
page 96.
Table 1-3. LCD Status Messages
(continued)
Code Text Causes Corrective Actions