About Your Solution 29
E1714 Unknown error.
Review & clear
SEL.
The system BIOS has
determined there has
been an error in the
system, but is unable to
determine its origin.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 113.
E171F PCIe fatal
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCIe fatal
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting an
Expansion Card" on
page 101.
E1810 Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
See "Troubleshooting a
Hard Drive" on page 100.
E1812 Hard drive ##
removed. Check
drive.
The specified hard
drive has been removed
from the system.
Information only.
E1920 iDRAC6 Upgrade
Failed.
iDRAC6 upgrade has
failed.
See "Getting Help" on
page 113.
E1A14 SAS cable A
failure. Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 113.
Table 1-3. LCD Status Messages
(continued)
Code Text Causes Corrective Actions