Dell OpenManage Server Administrator Version 6.0.1 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla NAS i serwery pamięci Dell OpenManage Server Administrator Version 6.0.1. Dell OpenManage Server Administrator Version 6.0.1 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 277
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - User's Guide

www.dell.com | support.dell.comDell™ OpenManage™Server Administrator Version 6.0.1Command Line InterfaceUser's Guide

Strona 2 - Notes, Cautions, and Warnings

10 Contentsomreport Storage Help . . . . . . . . . . . . . . . . . 151omreport Controller Status. . . . . . . . . . . . . 151omreport Global Inform

Strona 3 - Contents

100 omconfig: Managing Components Using the Instrumentation Serviceipsource=static | dhcp | systemsoftwarestatic: Static if the IP address of the BMC

Strona 4 - 4 Contents

omconfig: Managing Components Using the Instrumentation Service 101config=serial baudrate=9600 | 19200 | 38400 | 57600 | 1152009600: Sets the connect

Strona 5

102 omconfig: Managing Components Using the Instrumentation Serviceconfig=serial (continued)mode=directbasic | directterminal | directbasicterminal |

Strona 6 - Instrumentation Service 71

omconfig: Managing Components Using the Instrumentation Service 103config=serialoverlan enable=true | false true: Enables serial over LAN for the BMC.

Strona 7

104 omconfig: Managing Components Using the Instrumentation Serviceconfig=terminalmode (continued)echocontrol=enabled | disabledenabled: Enables chara

Strona 8 - Ownership Values 129

omconfig: Managing Components Using the Instrumentation Service 105config=user id=number enable=true | falseid=number: ID (in numeric format) of the u

Strona 9 - Management Service 147

106 omconfig: Managing Components Using the Instrumentation Serviceconfig=user (continued)id=number lanaccesslevel=administrator | operator | user| no

Strona 10 - 10 Contents

omconfig: Managing Components Using the Instrumentation Service 107config=user (continued)id=user id extimpiusergroup=admin | poweruser | custom | non

Strona 11

108 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassis temps/omconfig mainsystem tempsUse the omconfig chassis temps or o

Strona 12 - 12 Contents

omconfig: Managing Components Using the Instrumentation Service 109Setting Minimum and Maximum Warning Threshold ValuesIf you want to set both the upp

Strona 13 - Glossary 225

Contents 11omconfig Import Foreign Configuration . . . . . . 175omconfig Import/Recover Foreign Configuration . . . . . . . . . . . . . . . . . . .

Strona 14 - 14 Contents

110 omconfig: Managing Components Using the Instrumentation ServiceValid Parameters for Voltage Warning ThresholdsTable 4-16 shows the valid parameter

Strona 15 - Introduction

omconfig: Managing Components Using the Instrumentation Service 111When you issue the command and the system sets the values you specify, the followin

Strona 16

112 omconfig: Managing Components Using the Instrumentation ServiceTherefore, for a computer named "myOmsa" running Server Administrator, th

Strona 17 - Primary CLI Commands

omconfig: Managing Components Using the Instrumentation Service 113The parameters for configuring the SNMP root password are the same whether you conf

Strona 18 - Success Messages

114 omconfig: Managing Components Using the Instrumentation Serviceomconfig preferences useraccessDepending on the policies of your enterprise, you ma

Strona 19 - Failure Messages

omconfig: Managing Components Using the Instrumentation Service 115For example, if a fan probe on your system reads a fan RPM of 300 and your minimum

Strona 20

116 omconfig: Managing Components Using the Instrumentation ServiceComponents and Events for Which You Can Set Alert ActionsTable 4-22 lists the compo

Strona 21 - Command Syntax Overview

omconfig: Managing Components Using the Instrumentation Service 117 NOTE: storagectrlbatterywarn and storagectrlbatteryfail events are not available

Strona 22

118 omconfig: Managing Components Using the Instrumentation ServiceExample Current Probe ActionsTo disable system console alert if a current probe det

Strona 23 - Using the omhelp Command

omconfig: Managing Components Using the Instrumentation Service 119To clear the contents of the alert log, type:omconfig system alertlog action=clearo

Strona 24

12 Contentsomconfig Physical Disk Commands . . . . . . . . . . . 193omconfig Blink Physical Disk. . . . . . . . . . . . 194omconfig Unblink Physical

Strona 25 - Using the omhelp Command 25

120 omconfig: Managing Components Using the Instrumentation Serviceomconfig system platformevents/omconfig servermodule platformeventsUse the omconfig

Strona 26 - 26 Using the omhelp Command

omconfig: Managing Components Using the Instrumentation Service 121Table 4-25 lists the components and the events for which you can set platform event

Strona 27

122 omconfig: Managing Components Using the Instrumentation Serviceomconfig system events/omconfig servermodule eventsUse the omconfig system events o

Strona 28

omconfig: Managing Components Using the Instrumentation Service 123SourceAt present, source=snmptraps is a required name=value pair because SNMP is cu

Strona 29

124 omconfig: Managing Components Using the Instrumentation Servicethe same system chassis, you can specify whether you want to be notified for event

Strona 30

omconfig: Managing Components Using the Instrumentation Service 125omconfig system webserver/omconfig servermodule webserverUse the omconfig system we

Strona 31

126 omconfig: Managing Components Using the Instrumentation ServiceTo set the amount of time that the system must be hung before a recovery action is

Strona 32 - <command level 2> -?

omconfig: Managing Components Using the Instrumentation Service 127Example Shutdown CommandsTo set the shutdown action to reboot, type:omconfig system

Strona 33

128 omconfig: Managing Components Using the Instrumentation ServiceExample Thermal Shutdown CommandsTo trigger a thermal shutdown when a temperature p

Strona 34

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 1295omconfig system or servermodule assetinfo: Editing Cost of Ownership V

Strona 35

Contents 13omconfig Set All Temperature Probe Thresholds . . . . . . . . . . . . . . . . . . . . . 214omconfig Reset All Temperature Probe Thresholds

Strona 36

130 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesAdding Acquisition InformationAcquisition refers to the facts about a b

Strona 37

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 131Example Commands for Adding Acquisition InformationTo provide a value f

Strona 38

132 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesAdding Depreciation InformationDepreciation is a set of methods for com

Strona 39

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 133The following message appears:Asset information set successfully.You ca

Strona 40

134 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesExample Command for Adding Extended Warranty InformationTo provide a va

Strona 41

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 135Example Command for Adding Lease InformationTo provide a value for a le

Strona 42

136 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesAdding Maintenance InformationMaintenance refers to activities required

Strona 43

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 137You can enter more than one omconfig system assetinfo or omconfig serve

Strona 44

138 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesExample Command for Adding Outsource InformationTo provide a value for

Strona 45

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 139Example Command for Adding Owner InformationTo provide a value for an o

Strona 46

14 Contents

Strona 47

140 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesExample Command for Adding Service InformationTo provide a value for a

Strona 48

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 141Adding Support InformationSupport refers to technical assistance that t

Strona 49

142 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesExample Command for Adding Support InformationTo provide a value for a

Strona 50

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 143Adding System InformationSystem information includes the primary user o

Strona 51

144 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesAdding Warranty InformationUse the omconfig system warranty or omconfig

Strona 52

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 145The following message appears:Asset information set successfully.You ca

Strona 53

146 omconfig system or servermodule assetinfo: Editing Cost of Ownership Values

Strona 54

Using the Storage Management Service 1476Using the Storage Management ServiceThe CLI of Storage Management enables you to perform all of Storage Manag

Strona 55

148 Using the Storage Management ServiceTable 6-1 describes these command levels. Following the command levels, the omreport and omconfig command synt

Strona 56

Using the Storage Management Service 149Table 6-2. Syntax For Name=Value Pairs For ParametersSyntax Description controller=id Indicates the controller

Strona 57 - Commands for Viewing Logs

Introduction 151IntroductionYou can perform essential systems management tasks using Dell™ OpenManage™ Server Administrator’s graphical user interface

Strona 58

150 Using the Storage Management ServiceUser Privileges for omreport storage and omconfig storageStorage Management requires Administrator privileges

Strona 59

Using the Storage Management Service 151omreport Storage Help Table 6-3 provides the omreport storage command syntax. omreport Controller StatusTable

Strona 60

152 Using the Storage Management Serviceomreport Global Information (Smart Thermal Shutdown Status)Table 6-5 describes the syntax for the omreport Glo

Strona 61 - <component name>

Using the Storage Management Service 153omreport Connector Status Table 6-7describes the syntax for the omreport Connector Commands.omreport Enclosure

Strona 62

154 Using the Storage Management Serviceomreport Temperature Probe StatusTable 6-9 describes the syntax for the omreport Probe CommandsTable 6-9. omre

Strona 63

Using the Storage Management Service 155omreport Fan StatusTable 6-10 describes the syntax for the omreport Fan CommandsTable 6-10. omreport Fan Statu

Strona 64 - Example Command Output

156 Using the Storage Management Serviceomreport Power Supply StatusTable 6-11 describes the syntax for the omreport Power Supply CommandsTable 6-11.

Strona 65 - System Attributes

Using the Storage Management Service 157omreport EMM Status NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the

Strona 66 - Memory Array

158 Using the Storage Management Serviceomreport Physical Disk Status Table 6-13 describes the syntax for the omreport Physical Disk CommandsTable 6-1

Strona 67 - Firmware

Using the Storage Management Service 159omreport Virtual Disk Status Table 6-14 describes the syntax for the omreport Virtual Disk Commandsomconfig Gl

Strona 68

16 Introduction• Display of new memory types (DDR3 Registered, DDR3 Unregistered)• Display of new slot types (PCIe Gen1/2)• Enabling/disabling Non-Uni

Strona 69

160 Using the Storage Management Servicetemperature of 0 or 50° Celsius. Specifying that only the enclosure be shut down during excessive temperatures

Strona 70

Using the Storage Management Service 161Example SyntaxThe omconfig command syntax for disabling thermal shutdown does not require that you specify a c

Strona 71

162 Using the Storage Management ServiceTable 6-16. omconfig Controller CommandsRequired Command Levels (1, 2, 3) Optional name=value pairs omconfig s

Strona 72

Using the Storage Management Service 163omconfig Rescan Controller Use the following omconfig command syntax to rescan a controller. See Dell OpenMana

Strona 73

164 Using the Storage Management Serviceomconfig Enable Controller Alarm Use the following omconfig command syntax to enable the controller alarm. See

Strona 74

Using the Storage Management Service 165omconfig Quiet Controller Alarm Use the following omconfig command syntax to silence an activated controller a

Strona 75 - NOTE: You cannot

166 Using the Storage Management Serviceomconfig Reset Controller Configuration Use the following omconfig command syntax to reset the controller conf

Strona 76

Using the Storage Management Service 167For SCSI, SATA, and ATA Controllers pdisk=connector:enclosureID:portIDwhere connector:enclosureID:portID is th

Strona 77

168 Using the Storage Management Service[cachepolicy=<d | c>] Parameter (Optional)[readpolicy=<ra| nra| ara| rc| nrc>] Parameter (Optional

Strona 78

Using the Storage Management Service 169size=<number | max | min> Parameter (Required) Table 6-18 indicates how to specify the size=<number |

Strona 79

Introduction 17Using CLI Commands from Windows Command PromptsIf you are running the Microsoft Windows® operating system, use the 32-bit command promp

Strona 80

170 Using the Storage Management Service[cachepolicy=<d | c>] Parameter (Optional) Different controllers support different cache policies. Table

Strona 81

Using the Storage Management Service 171[writepolicy=<wb| wt| wc| nwc>] Parameter (Optional) Different controllers support different write polic

Strona 82

172 Using the Storage Management ServiceExample Syntax For example, you may want to create a RAID-5 virtual disk on a PERC 3/QC controller. See the De

Strona 83

Using the Storage Management Service 173omconfig Set Background Initialization RateUse the following omconfig command syntax to set the background ini

Strona 84

174 Using the Storage Management Serviceomconfig Set Check Consistency RateUse the following omconfig command syntax to set the check consistency rate

Strona 85

Using the Storage Management Service 175Depending on the controller, the log file name will either be afa_<mmdd>.log or lsi_<mmdd>.log whe

Strona 86

176 Using the Storage Management ServiceExample Syntax To import and recover foreign configurations on controller 1, enter: omconfig storage controlle

Strona 87

Using the Storage Management Service 177Example SyntaxTo set the patrol read on controller 1 to manual mode, enter:omconfig storage controller action=

Strona 88

178 Using the Storage Management ServiceExample SyntaxTo stop the patrol read task on controller 1, enter:omconfig storage controller action=stoppatro

Strona 89

Using the Storage Management Service 179Complete Syntaxomconfig storage vdisk action=replacememberdisk controller=id vdisk=id source=<PDISKID> d

Strona 90

18 IntroductionTable 1-1 lists the primary CLI commands used by Server Administrator. This guide contains a section for each primary command. NOTE: o

Strona 91

180 Using the Storage Management Serviceomconfig Virtual Disk Commands The following sections provide the omconfig command syntax required to execute

Strona 92

Using the Storage Management Service 181omconfig Blink Virtual Disk Use the following omconfig command syntax to blink the physical disks included in

Strona 93

182 Using the Storage Management Serviceomconfig Initialize Virtual Disk Use the following omconfig command syntax to initialize a virtual disk. Compl

Strona 94

Using the Storage Management Service 183omconfig Fast Initialize Virtual DiskUse the following omconfig command syntax to fast initialize a virtual di

Strona 95

184 Using the Storage Management Serviceomconfig Cancel Background Initialize Use the following omconfig command syntax to cancel the background initi

Strona 96

Using the Storage Management Service 185omconfig Split Mirror Use the following omconfig command syntax to separate mirrored data originally configure

Strona 97

186 Using the Storage Management ServiceComplete Syntax omconfig storage vdisk action=unmirror controller=id vdisk=id where id is the controller ID an

Strona 98

Using the Storage Management Service 187Example for SCSI, SATA, and ATA Controllers To assign the dedicated hot spare described in this example, enter

Strona 99

188 Using the Storage Management ServiceExample for SCSI, SATA, and ATA Controllers To unassign the dedicated hot spare described in this example, ent

Strona 100 - (continued)

Using the Storage Management Service 189omconfig Cancel Check Consistency Use the following omconfig command syntax to cancel a check consistency whil

Strona 101

Introduction 19Message:Temperature probe warning threshold value(s) set successfully.Command:omconfig chassis biossetup attribute=speaker setting=on M

Strona 102

190 Using the Storage Management Serviceomconfig Resume Check Consistency Use the following omconfig command syntax to resume a check consistency afte

Strona 103

Using the Storage Management Service 191omconfig Format Virtual Disk Use the following omconfig command syntax to format a virtual disk. Complete Synt

Strona 104

192 Using the Storage Management ServiceExample for SCSI, SATA, and ATA Controllers In this example, enter: omconfig storage vdisk action=reconfigure

Strona 105

Using the Storage Management Service 193Example Syntax To change the read policy of virtual disk 4 on controller 1 to no-read-ahead, enter: omconfig s

Strona 106

194 Using the Storage Management Serviceomconfig Blink Physical Disk You can blink the light (light emitting diode or LED display) on one or more phys

Strona 107 - NOTE: extimpiusergroup

Using the Storage Management Service 195Example for SAS Controllers To blink the physical disk described in this example, enter: omconfig storage pdis

Strona 108

196 Using the Storage Management Serviceomconfig Prepare to Remove Physical Disk Use the following omconfig command syntax to prepare a physical disk

Strona 109

Using the Storage Management Service 197omconfig Initialize Physical Disk Use the following omconfig command syntax to initialize a physical disk. Com

Strona 110

198 Using the Storage Management Serviceomconfig Offline Physical Disk Use the following omconfig command syntax to offline a physical disk: Complete

Strona 111

Using the Storage Management Service 199Example for SCSI, SATA, and ATA Controllers To offline the physical disk described in this example, enter: omc

Strona 112

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indica

Strona 113

20 IntroductionTy p e :omconfig chassis volts index=3 minwarnthresh=3.300When you enter the revised command with three decimal points, you receive ano

Strona 114 - Defining Alert Actions

200 Using the Storage Management Serviceomconfig Assign Global Hot Spare Use the following omconfig command syntax to assign a physical disk as a glob

Strona 115 - Available Alert Actions

Using the Storage Management Service 201omconfig Unassign Global Hot Spare Use the following omconfig command syntax to unassign a physical disk as a

Strona 116

202 Using the Storage Management Serviceomconfig Rebuild Physical Disk Use the following omconfig command syntax to rebuild a failed physical disk. Re

Strona 117

Using the Storage Management Service 203omconfig Cancel Rebuild Physical DiskUse the following omconfig command syntax to cancel a rebuild that is in

Strona 118 - Commands for Clearing Logs

204 Using the Storage Management Serviceomconfig Remove Dead Segments Use the following omconfig command syntax to recover unusable disk space. See th

Strona 119

Using the Storage Management Service 205omconfig Clear Physical DiskUse the following omconfig command to clear data or a configuration from a physica

Strona 120

206 Using the Storage Management ServiceExample Syntax In this example, you want to cancel the clear of physical disk 3 on connector 0 of controller 1

Strona 121

Using the Storage Management Service 207omconfig Recondition Battery Use the following omconfig command to recondition a controller battery. See the D

Strona 122

208 Using the Storage Management Serviceomconfig Delay Battery Learn CycleUse the following omconfig command to delay the battery learn cycle for a sp

Strona 123 - Severity

Using the Storage Management Service 209Complete Syntax omconfig storage connector action=rescan controller=id connector=id where id is the controller

Strona 124

Introduction 21variables such as owner, primary user phone number, asset tag, and so on. Scripts to populate unique values would set all unique variab

Strona 125 - Example Recovery Commands

210 Using the Storage Management Serviceomconfig Enclosure Commands The following sections provide the omconfig command syntax required to execute enc

Strona 126

Using the Storage Management Service 211Example for SCSI, SATA, and ATA Controllers To enable the alarm on the enclosure attached to connector 2 on co

Strona 127 - Example Shutdown Commands

212 Using the Storage Management Serviceomconfig Set Enclosure Asset Tag Use the following omconfig command syntax to specify the enclosure’s asset ta

Strona 128

Using the Storage Management Service 213Example for SCSI, SATA, and ATA Controllers To specify the asset name to encl43 for the enclosure attached to

Strona 129 - Ownership Values

214 Using the Storage Management ServiceExample for SCSI, SATA, and ATA Controllers In this example, temperature probe 3 resides in the enclosure atta

Strona 130

Using the Storage Management Service 215Complete Syntaxomconfig storage enclosure action=setalltempprobes controller=id enclosure=<ENCLOSUREID>

Strona 131

216 Using the Storage Management ServiceExample Syntax For example, you may want to reset the thresholds for all temperature probes in enclosure 2 on

Strona 132

Working With CLI Command Results 2177Working With CLI Command ResultsServer Administrator Command Line Interface (CLI) users can use the command outpu

Strona 133

218 Working With CLI Command ResultsSUSE® Linux Enterprise Server terminal. To display command output with control over scrolling, type the CLI comman

Strona 134 - Adding Lease Information

Working With CLI Command Results 219Four hours later, you repeat the command. You have no interest in the 11:00 A.M. snapshot as written to fans.txt.

Strona 135

22 IntroductionMany commands use command level 1, command level 2, and command level 3, but do not require any parameters (name=value pairs). Most omr

Strona 136

220 Working With CLI Command ResultsFans.txt now reads as follows:You can use a text editor to insert the time that each block of data was captured. I

Strona 137 - Adding Outsource Information

Working With CLI Command Results 221The available formats include: •List (lst)• Semicolon-separated values (ssv)•Table (tbl)•Raw XML (xml)• Custom del

Strona 138 - Adding Owner Information

222 Working With CLI Command ResultsNo special formatting option is required because list format is the default display format. The network data part

Strona 139

Working With CLI Command Results 223Semicolon-separated Values (ssv)Use the ssv formatting option to deliver output formatted in semicolon-separated v

Strona 140

224 Working With CLI Command ResultsCustom Delimited Format (cdv)Use the cdv formatting option to report exported data in custom delimited format. You

Strona 141 - Adding Support Information

Glossary 225GlossaryThe following list defines or identifies technical terms, abbreviations, and acronyms used in Dell™user documents.AAbbreviation fo

Strona 142

226 GlossaryASICAcronym for application-specific integrated circuit.ASPIAdvanced SCSI programming interface.ASRAbbreviation for automatic system recov

Strona 143 - Adding System Information

Glossary 227backupA copy of a program or data file. As a precaution, back up your computer's hard drive on a regular basis. Before changing the c

Strona 144 - Adding Warranty Information

228 Glossarybootable disketteYou can start your computer from a diskette. To make a bootable diskette, insert a diskette in the diskette drive, type s

Strona 145

Glossary 229capabilityRefers to the actions that an object can perform, or actions that can be taken on a managed object. For example, if a card is ho

Strona 146

Using the omhelp Command 232Using the omhelp CommandThe omhelp command and its equivalent, <command> -?, accesses the CLI's detailed help t

Strona 147 - Using the Storage Management

230 GlossaryCI/OAcronym for comprehensive input/output.cmAbbreviation for centimeter(s).CMCAcronym for Chassis Management Controller.CMOSAcronym for c

Strona 148 - Command Elements

Glossary 231conventional memoryThe first 640 KB of RAM. Conventional memory is found in all computers. Unless they are specially designed, MS-DOS® pro

Strona 149

232 GlossarycursorA marker, such as a block, underscore, or pointer that represents the position at which the next keyboard or mouse action will occur

Strona 150

Glossary 233DIPAcronym for dual in-line package. A circuit board, such as a system board or expansion card, may contain DIP switches for configuring t

Strona 151

234 GlossaryDRAMAcronym for dynamic random-access memory. A computer's RAM is usually made up entirely of DRAM chips. Because DRAM chips cannot s

Strona 152 - Commands

Glossary 235• Support for up to two controllers, each with up to two devices attachedEISAAcronym for Extended Industry-Standard Architecture, a 32-bit

Strona 153

236 GlossaryERA/OAcronym for embedded remote access option.ESDAbbreviation for electrostatic discharge.ESMAcronym for embedded server management.expan

Strona 154

Glossary 237FCCAbbreviation for Federal Communications Commission.FEPROMAcronym for Flash Erasable Programmable Read-Only Memory. Flash memory is a ki

Strona 155

238 GlossaryGBAbbreviation for gigabyte(s). A gigabyte equals 1,024 megabytes or 1,073,741,824 bytes.graphics coprocessorSee coprocessor.groupAs it re

Strona 156

Glossary 239hot plugThe ability to remove and replace a redundant part while the system is being used. Also called a "hot spare."HPFSAbbrevi

Strona 157

24 Using the omhelp Command• thrmshutdown• webserverFigure 2-1 shows the levels of help for a command.Figure 2-1. Different Levels of Help for a Comma

Strona 158 - Replacing

240 GlossaryIHVAcronym for independent hardware vendor. IHVs often develop their own MIBs for components that they manufacture.interlacingA technique

Strona 159

Glossary 241ISAAcronym for Industry-Standard Architecture. A 16-bit expansion bus design. The expansion-card connectors in an ISA computer are also co

Strona 160 - ° Celsius

242 Glossarykey combinationA command requiring you to press multiple keys at the same time. For example, you can reboot your computer by pressing the

Strona 161 - Complete Syntax

Glossary 243LOMAcronym for LAN on Motherboard.LPTnThe device names for the first through third parallel printer ports on your computer are LPT1, LPT2,

Strona 162

244 GlossaryMbpsAbbreviation for megabits per second.MBRAbbreviation for master boot record.MCAAbbreviation for Micro Channel Architecture, which is d

Strona 163

Glossary 245MIDIAbbreviation for musical instrument digital interface.MIFAcronym for management information format. A MIF file contains information, s

Strona 164

246 GlossarymVAbbreviation for millivolt(s).nameThe name of an object or variable is the exact string that identifies it in an SNMP Management Informa

Strona 165

Glossary 247NVRAMAcronym for non-volatile random-access memory. Memory that does not lose its contents when you turn off your computer. NVRAM is used

Strona 166

248 GlossaryPCIAbbreviation for Peripheral Component Interconnect. A standard for local-bus implementation developed by Intel Corporation.PCMCIAPerson

Strona 167 - For SAS Controllers

Glossary 249Plug and PlayAn industry-standard specification that makes it easier to add hardware devices to personal computers. Plug and Play provides

Strona 168

Using the omhelp Command 25For one info value, specify one or more optional parameter(s). Table 2-1 displays the optional parameters for info=acquisit

Strona 169 - Table 6-18. Size Parameter

250 Glossaryprotected modeAn operating mode supported by 80286 or higher microprocessors, protected mode allows operating systems to implement:• A mem

Strona 170

Glossary 251RAMAcronym for random-access memory. The computer's primary temporary storage area for program instructions and data. Each location i

Strona 171 - RAID 10)

252 Glossaryreadme fileA text file included with a software package or hardware product that contains information supplementing or updating the docume

Strona 172

Glossary 253RTCAbbreviation for real-time clock. Battery-powered clock circuitry inside the computer that keeps the date and time after you turn off t

Strona 173

254 Glossaryservice tag numberA bar code label on the computer that identifies it when you call Dell for customer or technical support.SGRAMAcronym fo

Strona 174

Glossary 255SMTPAcronym for Simple Mail Transfer Protocol, a method for exchanging e-mail over the internet.SNMPAbbreviation for Simple Network Manage

Strona 175

256 GlossaryTwo common DIP switches are used on system boards: slide switches and rocker switches. The names of the switches are based on how the sett

Strona 176

Glossary 257system.ini fileA start-up file for the Windows operating system. When you start Windows, it consults the system.ini file to determine a va

Strona 177

258 Glossary• LowerThresholdNon-critical• LowerThresholdCritical• LowerThresholdFataltime-outA specified period of system inactivity that must occur b

Strona 178

Glossary 259unicodeA fixed width, 16-bit world wide character encoding, developed and maintained by the Unicode Consortium.upper memory areaThe 384 KB

Strona 179

26 Using the omhelp Command

Strona 180

260 GlossaryvariableA component of a managed object. A temperature probe, for example, has a variable to describe its capabilities, its health or stat

Strona 181

Glossary 261video driverA program that allows graphics-mode application programs and operating systems to display at a chosen resolution with the desi

Strona 182

262 GlossaryVLSIAbbreviation for very-large-scale integration.VLVESAAcronym for very low voltage enterprise system architecture.vppAbbreviation for pe

Strona 183

Glossary 263win.ini fileA start-up file for the Windows operating system. When you start Windows, it consults the win.ini file to determine a variety

Strona 184

264 Glossary

Strona 185

Index 265IndexSymbols-?omconfig, 77omconfig chassis, 79omreport, 32request for help, 23Aaboutomconfig, 78acquisitioninformation, 130optional parameter

Strona 186

Index 266biosomreport chassis, 36biossetupomconfig chassis, 79omreport chassis, 37blinkomconfig, 216blink physical diskomconfig, 194bmcomconfig chassi

Strona 187 - Example for SAS Controllers

Index 267cmdlogomconfig system, 119omreport system, 57command levels 1,2, and 3omconfig, 72command levels 1,2,3omreport, 29command syntax overview, 21

Strona 188

Index 268defining alert actions, 114delay battery learn cycleomconfig, 208delete virtual diskomconfig, 190delimitersdata fields, 111depreciation infor

Strona 189

Index 269fancontrolomconfig chassis, 89omreport chassis, 40fansomconfig chassis, 88omreport chassis, 40firmwareomreport chassis, 41format virtual disk

Strona 190

omreport: Viewing System Status Using the Instrumentation Service 273omreport: Viewing System Status Using the Instrumentation ServiceThe omreport com

Strona 191

Index 270maximum warning threshold, 109memoryarrays, 30, 66omreport chassis, 44memorymodeomconfig chassis, 93minimum warning threshold, 109Nname=value

Strona 192

Index 271rescan controller, 163reset controller configuration, 166reset temperature probe thresholds, 214-215restore dead segments, 184resume check co

Strona 193

Index 272omconfig enclosure commands, 210omconfig global commands, 159omconfig physical disk commands, 193omconfig preferences, 111cdvformat, 111dirse

Strona 194

Index 273omconfig virtual disk commands, 180omhelp, 17, 23omreport-?, 32about, 34battery status, 152chassis, 35command levels 1, 2, 3, 29command summa

Strona 195

Index 274index, 55slot ID, 55omreport modularchassis, 32omreport storagebattery, 152-153controller, 151enclosure, 153-157globalinfo, 152pdisk, 158vdis

Strona 196

Index 275primary CLI commandomconfig, 17omhelp, 17, 23omreport, 17primary CLI commands, 17processor familyomreport chassis processors, 47processor ver

Strona 197

Index 276shutdownomconfig system, 126omreport system, 64shutdown actionomconfig system platformevents, 120slot IDomreport chassis slots, 55slotsomrepo

Strona 198

Index 277unmirroromconfig, 185user access to Server Administratoradministrators only, 114determining, 114least restrictive, 114most restrictive, 114po

Strona 199

28 omreport: Viewing System Status Using the Instrumentation ServiceConventions for Parameter TablesWhen listing the parameters that a command can tak

Strona 200

omreport: Viewing System Status Using the Instrumentation Service 29Table 3-2. Command Level 1, Level 2, and Level 3 for omreportCommand Level 1Comma

Strona 201

Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 15What's New for Version 6.0.1 . . . . . . . . . . . . . . 15Us

Strona 202

30 omreport: Viewing System Status Using the Instrumentation Serviceinfo U, P, A Shows a status summary for main system chassis components.intrusion U

Strona 203

omreport: Viewing System Status Using the Instrumentation Service 31storage U, P, A See "Using the Storage Management Service."system/server

Strona 204

32 omreport: Viewing System Status Using the Instrumentation ServiceHelp With the omreport CommandUse the omreport -? command to get a list of the ava

Strona 205

omreport: Viewing System Status Using the Instrumentation Service 33Modular Chassis InformationChassis InformationAttribute : ModelValue : Modular Ser

Strona 206

34 omreport: Viewing System Status Using the Instrumentation Serviceomreport aboutUse the omreport about command to learn the product name and version

Strona 207

omreport: Viewing System Status Using the Instrumentation Service 35omreport chassis/omreport mainsystem CommandsUse the omreport chassis or omreport

Strona 208

36 omreport: Viewing System Status Using the Instrumentation ServiceServer Administrator displays the following output:Server Administrator reports va

Strona 209

omreport: Viewing System Status Using the Instrumentation Service 37Server Administrator displays the summary of the BIOS information for your system.

Strona 210

38 omreport: Viewing System Status Using the Instrumentation ServiceNIC 1 Displays whether the first NIC is enabled (with or without PXE/iSCSI) or di

Strona 211

omreport: Viewing System Status Using the Instrumentation Service 39Parallel port address Displays whether the address is located on LPT1, LPT2, and L

Strona 212

4 Contentsomreport modularenclosure . . . . . . . . . . . . . . . 32omreport about . . . . . . . . . . . . . . . . . . . . . 34omreport chassis/om

Strona 213

40 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis bmc/omreport mainsystem bmcThis command is phased-out in this rel

Strona 214

omreport: Viewing System Status Using the Instrumentation Service 41omreport chassis firmware/omreport mainsystem firmwareUse the omreport chassis fir

Strona 215 - ° Celsius, enter:

42 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis hwperformance/omreport mainsystem hwperformanceUse the omreport c

Strona 216

omreport: Viewing System Status Using the Instrumentation Service 43Depending on your configuration, output may resemble the following example:omrepor

Strona 217

44 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis leds/omreport mainsystem ledsUse the omreport chassis leds or omr

Strona 218

omreport: Viewing System Status Using the Instrumentation Service 45An unoccupied memory slot still has a connector name. Output for an unoccupied mem

Strona 219

46 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis nics/omreport mainsystem nicsUse the omreport chassis nics or omr

Strona 220

omreport: Viewing System Status Using the Instrumentation Service 47Maximum Speed is the port speed. Port speed refers to the data transmission rate o

Strona 221 - List (lst)

48 omreport: Viewing System Status Using the Instrumentation ServiceThe following fields are defined for the capabilities present on a particular micr

Strona 222 - Table (tbl)

omreport: Viewing System Status Using the Instrumentation Service 49Speed refers to the rate at which the cache can forward data from the main memory

Strona 223 - Raw XML (xml)

Contents 5omreport chassis memory/omreport mainsystem memory . . . . . . . . . . . . . . . . 44omreport chassis nics/omreport mainsystem nics . . .

Strona 224 - Custom Delimited Format (cdv)

50 omreport: Viewing System Status Using the Instrumentation ServiceExternal Socket Name Silk Screen Name is the name printed on the system board next

Strona 225 - Glossary

omreport: Viewing System Status Using the Instrumentation Service 51omreport chassis pwrmonitoring/omreport mainsystem pwrmonitoringUse the omreport c

Strona 226

52 omreport: Viewing System Status Using the Instrumentation Service•Reading •System Peak Power•System Peak Amperage NOTE: The omreport chassis pwrmo

Strona 227 - Glossary 227

omreport: Viewing System Status Using the Instrumentation Service 53omreport chassis pwrsupplies/omreport mainsystem pwrsuppliesUse the omreport chass

Strona 228

54 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis remoteaccess/omreport mainsystem remoteaccessUse the omreport cha

Strona 229 - Glossary 229

omreport: Viewing System Status Using the Instrumentation Service 55omreport chassis slots/omreport mainsystem slotsUse the omreport chassis slots or

Strona 230

56 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis volts/omreport mainsystem voltsUse the omreport chassis volts or

Strona 231 - Glossary 231

omreport: Viewing System Status Using the Instrumentation Service 57 NOTE: As with all output shown in this guide, the following output is an example

Strona 232

58 omreport: Viewing System Status Using the Instrumentation ServiceHealth: OK means that less than 80 percent of the space allotted for the ESM log i

Strona 233 - Glossary 233

omreport: Viewing System Status Using the Instrumentation Service 59• System Power Probe Detects a Failure• System Peak Power •Power Supply Warning• P

Strona 234

6 Contentsomreport system pedestinations/omreport servermodule pedestinations . . . . . . 62omreport system platformevents/omreport servermodule pl

Strona 235 - Glossary 235

60 omreport: Viewing System Status Using the Instrumentation Serviceomreport system assetinfo/omreport servermodule assetinfoUse the omreport system a

Strona 236

omreport: Viewing System Status Using the Instrumentation Service 61-----------Fans-----------SettingsEnable: CriticalDisable: Informational and Warni

Strona 237 - Glossary 237

62 omreport: Viewing System Status Using the Instrumentation ServiceExample Command for an Event TypeTy p e :omreport system events type=fansoromrepor

Strona 238

omreport: Viewing System Status Using the Instrumentation Service 63Table 3-8 shows the available settings.Table 3-8. Settings for the omreport system

Strona 239 - Glossary 239

64 omreport: Viewing System Status Using the Instrumentation Serviceomreport system platformevents/omreport servermodule platformeventsUse the omrepor

Strona 240

omreport: Viewing System Status Using the Instrumentation Service 65The output that appears in your CLI window depends on the systems management softw

Strona 241 - Glossary 241

66 omreport: Viewing System Status Using the Instrumentation ServiceMain System Chassis/Main SystemChassis• Chassis Model• Chassis Service Tag• Chassi

Strona 242

omreport: Viewing System Status Using the Instrumentation Service 67• Slots Available•Slots Used•Ecc TypeBIOS • Manufacturer •BIOS Version• Release Da

Strona 243 - Glossary 243

68 omreport: Viewing System Status Using the Instrumentation Serviceomreport system thrmshutdown/omreport servermodule thrmshutdownUse the omreport sy

Strona 244

omreport: Viewing System Status Using the Instrumentation Service 69The output that appears in your CLI window depends on the version of the BIOS, RAI

Strona 245 - Glossary 245

Contents 7omconfig chassis frontpanel/omconfig mainsystem frontpanel . . . . . . . . . . . . . . . 90omconfig chassis info/omconfig mainsystem info

Strona 246

70 omreport: Viewing System Status Using the Instrumentation Service

Strona 247 - Glossary 247

omconfig: Managing Components Using the Instrumentation Service 714omconfig: Managing Components Using the Instrumentation ServiceThe omconfig command

Strona 248

72 omconfig: Managing Components Using the Instrumentation ServiceConventions for Parameter TablesWhen listing the parameters that a command can take,

Strona 249 - Glossary 249

omconfig: Managing Components Using the Instrumentation Service 73preferencescdvformat A Specifies the delimiter for separating data fields reported i

Strona 250

74 omconfig: Managing Components Using the Instrumentation Servicecmdlog P, A Allows the administrator to clear the command log.esmlog P, A Allows the

Strona 251

omconfig: Managing Components Using the Instrumentation Service 75chassis/ mainsystembiossetup A Configures the behavior of specific system components

Strona 252

76 omconfig: Managing Components Using the Instrumentation Serviceleds P, A Specifies when to flash a chassis fault LED or chassis identification LED,

Strona 253 - Glossary 253

omconfig: Managing Components Using the Instrumentation Service 77Help With the omconfig CommandUse the omconfig -? command to get a list of the avail

Strona 254

78 omconfig: Managing Components Using the Instrumentation ServiceIn the case of the omconfig system alertaction command, you can use various options

Strona 255 - Glossary 255

omconfig: Managing Components Using the Instrumentation Service 79Server Administrator includes a number of services, each of which has a version numb

Strona 256 - • Various ROM chips

8 Contentsomconfig system recovery/omconfig servermodule recovery . . . . . . . . . . . . . . . 125omconfig system shutdown/omconfig servermodule shu

Strona 257 - • UpperThresholdNon-critical

80 omconfig: Managing Components Using the Instrumentation ServiceTable 4-3 shows the name=value pairs you can use with this command.Table 4-3. BIOS S

Strona 258 - • LowerThresholdFatal

omconfig: Managing Components Using the Instrumentation Service 81attribute=dbs setting=enable | disable enable: Enables Demand Based Power Management

Strona 259 - Glossary 259

82 omconfig: Managing Components Using the Instrumentation Serviceattribute=extserial setting=com1 | com2 | rad com1: Maps external serial connector t

Strona 260

omconfig: Managing Components Using the Instrumentation Service 83attribute=nic1 setting=enabled | enabledwithpxe | disabled | enabledonly | enabledno

Strona 261 - Glossary 261

84 omconfig: Managing Components Using the Instrumentation Serviceattribute=nic3 setting=enabled | enabledwithpxe | disabled | enabledonly | enabledno

Strona 262

omconfig: Managing Components Using the Instrumentation Service 85attribute=ppaddress setting=off | lpt1 | lpt2 | lpt3off: Disables the parallel port

Strona 263 - Glossary 263

86 omconfig: Managing Components Using the Instrumentation Serviceattribute=sata setting=off | ata | raid off: Disables the SATA controller.ata: Sets

Strona 264 - 264 Glossary

omconfig: Managing Components Using the Instrumentation Service 87attribute=serialport2setting=off | auto | com2 |com4off: Disables serial port 2.auto

Strona 265 - Index 265

88 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassis bmc/omconfig mainsystem bmc NOTE: This command is phased-out in th

Strona 266 - Index 266

omconfig: Managing Components Using the Instrumentation Service 89You cannot default one value and set another. In other words, if you default the min

Strona 267 - Index 267

Contents 9Adding Outsource Information . . . . . . . . . . . . . 137Example Command for Adding Outsource Information. . . . . . . . . . . . . . . 1

Strona 268 - Index 268

90 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassis frontpanel/omconfig mainsystem frontpanelUse the omconfig chassis f

Strona 269 - Index 269

omconfig: Managing Components Using the Instrumentation Service 91omconfig chassis info/omconfig mainsystem infoUse the omconfig chassis info or omcon

Strona 270 - Index 270

92 omconfig: Managing Components Using the Instrumentation ServiceIndex 0 always defaults to the main system chassis. The following command omits inde

Strona 271 - Index 271

omconfig: Managing Components Using the Instrumentation Service 93omconfig chassis memorymode/omconfig mainsystem memorymodeUse the omconfig chassis m

Strona 272 - Index 272

94 omconfig: Managing Components Using the Instrumentation ServiceTable 4-9 shows the valid parameters for the command.omconfig chassis pwrmanagement/

Strona 273 - Index 273

omconfig: Managing Components Using the Instrumentation Service 95unit=watt | btuphr | percentwatt: Displays the unit in Watts.btuphr: Displays the un

Strona 274 - Index 274

96 omconfig: Managing Components Using the Instrumentation Service NOTE: Reboot your system for the power profiles setup options to take effect.omcon

Strona 275 - Index 275

omconfig: Managing Components Using the Instrumentation Service 97omconfig chassis pwrmonitoring config=probe index=0 warnthresh=settodefaultoromconfi

Strona 276 - Index 276

98 omconfig: Managing Components Using the Instrumentation Service• Advanced settings for a serial over LAN connection.• Information on a BMC or RAC u

Strona 277 - Index 277

omconfig: Managing Components Using the Instrumentation Service 99nicselection=sharedwithfailoveronall | nic1 | teamednic1nic2 | dracnicsharedwithfail

Komentarze do niniejszej Instrukcji

Brak uwag