Storage Management Group 601
Temperature Probe Maximum Warning
Temperature Probe Maximum Critical
Temperature Probe Current Value
Name temperatureProbeMaxWarning
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.9
Description Identifies the maximum temperature that will force the probe into
a warning state.
Syntax Integer
Access Read-only
Name temperatureProbeMaxCritical
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.10
Description Identifies the maximum temperature that will force the probe into
an error state.
Syntax Integer
Access Read-only
Name temperatureProbeCurValue
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.11
Description Identifies the current temperature of this probe.
Syntax Integer
Access Read-only