Dell OpenManage Server Administrator Version 6.1 Podręcznik Użytkownika Strona 687

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 776
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 686
Traps 687
Amperage Probe Traps
Amperage probes measure the amount of current (in amperes) that is
traversing critical components.
Table 26-6. Amperage Probe Traps
Trap ID Description Severity Cause
Amperage Probe Normal
1202 Current sensor returned to
a normal value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is discrete:
Discrete current state:
<State>
Information A current sensor on the
power supply for the
specified system
returned to a valid range
after crossing a failure
threshold. The sensor
location, chassis
location, previous state,
and current sensor value
are provided.
Amperage Probe Warning
1203 Current sensor detected a
warning value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is discrete:
Discrete current state:
<State>
Warning A current sensor on the
power supply for the
specified system
exceeded its warning
threshold. The sensor
location, chassis
location, previous state,
and current sensor value
are provided.