IPMI 1.5 / 2.0 Command Support List | 44
Does not support
parameter 14, 15.
Set Last Processed Event
ID
S/E 14h M
Yes
No
Get Last Processed Event
ID
S/E 15h M
Yes
No
Alert Immediate S/E 16h M
Yes
No
PET Acknowledge S/E 17h M
Yes
No
OEM Command List
Port Map Configure Command
Table 7-13-1. Port Map Configure Command
Port Map Configure Command NetFn CMD
Fail Over OEM command 34h C8h
Detail Information
Table 7-13-2. Port Map Configure Command Detail Information
Failover OEM command Byte Data Field
Request Data 1 Bit7 : Get/Set configure
0 : Get configure
1 : Set configure
Bit6 ~ bit4: Control by
01 : Jumper
02 : BMC
Bit3 : Enable/Disable Fail Over 1
0 : Enable(1 to 4)
1 : Disable(1 to 2)