Dell OpenManageServer Administrator Version 7.1.2Messages ReferenceGuide
10 Introduction•Pluggable Device Sensor — Monitors the addition, removal, or configuration errors for some pluggable devices, such as memory cards.•Ba
100 Storage Management Message Reference2108 SMART warningWarning / Non-criticalCause: A disk has received a SMART alert (predictive failure). The dis
Storage Management Message Reference 1012109 SMART warning temperatureWarning / Non-criticalCause: A disk has reached an unacceptable temperature and
102 Storage Management Message Reference2109 contdMake sure the enclosure has enough ventilation and that the room temperature is not too hot. See the
Storage Management Message Reference 1032110 SMART warning degradedWarning / Non-criticalCause: A disk is degraded and has received a SMART alert (pre
104 Storage Management Message Reference2112 Enclosure was shut downCritical / Failure / ErrorCause: The physical disk enclosure is either hotter or c
Storage Management Message Reference 1052114 A consistency check on a virtual disk has been paused (suspended)OK / Normal / InformationalCause: The ch
106 Storage Management Message Reference2116 A virtual disk and its mirror have been splitOK / Normal / InformationalCause: A user has caused a mirror
Storage Management Message Reference 1072118 Change write policyOK / Normal / InformationalCause: Auser has changed the write policy for a virtual dis
108 Storage Management Message Reference2121 Device returned to normalOK / Normal / InformationalCause: A device that was previously in an error state
Storage Management Message Reference 1092122 Redundancy degradedWarning / Non-criticalCause: One or more of the enclosure components has failed. For e
Introduction 11The location of the event log file depends on the operating system you are using.• On systems running the Microsoft Windows operating s
110 Storage Management Message Reference2122 contd.The controller status displayed on the Health subtab indicates whether a controller has a Failed or
Storage Management Message Reference 1112123 Redundancy lostWarning / Non-criticalCause: A virtual disk or an enclosure has lost data redundancy. In t
112 Storage Management Message Reference2123 contd.The controller status displayed on the Health subtab indicates whether a controller has a Failed or
Storage Management Message Reference 1132124 Redundancy normal OK / Normal / InformationalCause: Data redundancy has been restored to a virtual disk o
114 Storage Management Message Reference2126 SCSI sense sector reassignWarning / Non-criticalCause: A sector of the physical disk is corrupted and dat
Storage Management Message Reference 1152127 Background initialization (BGI) startedOK / Normal / InformationalCause: BGI of a virtual disk has starte
116 Storage Management Message Reference2130 BGI completed OK / Normal / InformationalCause: BGI of a virtual disk has completed. This alert is for in
Storage Management Message Reference 1172132 Driver version mismatchWarning / Non-criticalCause: The controller driver is not a supported version.Acti
118 Storage Management Message Reference2136 Virtual disk initializationOK / Normal / InformationalCause: Virtual disk initialization is in progress.
Storage Management Message Reference 1192137 Communica-tion timeoutWarning / Non-criticalCause: The controller is unable to communicate with an enclos
12 Introductionsrvadmin-deng/ini directory and set the property UnitextLog.enabled=true. Run the /etc/init.d/dataeng restart command to restart the Se
120 Storage Management Message Reference2137contd.Action: Check for problems with the cables. See the online help for more information on checking the
Storage Management Message Reference 1212139 Enclosure alarm disabledOK / Normal / InformationalCause: A user has disabled the enclosure alarm.Action:
122 Storage Management Message Reference2142 Controller rebuild rate has changedOK / Normal / InformationalCause: A user has changed the controller re
Storage Management Message Reference 1232145 Controller battery lowWarning / Non-criticalCause: The controller battery charge is low.Action: Reconditi
124 Storage Management Message Reference2149 Bad block extended sense errorWarning / Non-criticalCause: A portion of a physical disk is damaged.Action
Storage Management Message Reference 1252153 Enclosure service tag changedOK / Normal / InformationalCause: An enclosure service tag was changed. In m
126 Storage Management Message Reference2157 Controller configuration has been resetOK / Normal / InformationalCause: A user has reset the controller
Storage Management Message Reference 1272159 Virtual disk renamedOK / Normal / InformationalCause: A user has renamed a virtual disk. When renaming a
128 Storage Management Message Reference2161 Dedicated hot spare unassignedOK / Normal / InformationalCause: A physical disk that was assigned as a ho
Storage Management Message Reference 1292161 Cont.Action: Although this alert is provided for informational purposes, you may need to assign a new hot
Introduction 13 NOTE: These messages are typically displayed as one long line. In the following example, the message is displayed using line breaks t
130 Storage Management Message Reference2164 See the Readme file for a list of validated controller driver versionsOK / Normal / InformationalCause: S
Storage Management Message Reference 1312165 The RAID controller firmware and driver validation was not performed. The configuration file cannot be op
132 Storage Management Message Reference2166 The RAID controller firmware and driver validation was not performed. The configuration file is out of d
Storage Management Message Reference 1332167 The current kernel version and the non-RAID SCSI driver version are older than the minimum required level
134 Storage Management Message Reference2168 The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the validat
Storage Management Message Reference 1352170 The controller battery charge level is normal.OK / Normal / InformationalCause: This alert is for informa
136 Storage Management Message Reference2172 The controller battery temperature is normal.OK / Normal / InformationalCause: This alert is for informat
Storage Management Message Reference 1372174 The controller battery has been removed.Warning / Non-criticalCause: The controller cannot communicate wi
138 Storage Management Message Reference2176 The controller battery Learn cycle has started.OK / Normal / InformationalCause: This alert is for inform
Storage Management Message Reference 1392178 The controller battery Learn cycle has timed out.Warning / Non-criticalCause: The controller battery must
14 Introduction•User — The name of the user on whose behalf the event occurred. •Computer — The name of the system where the event occurred.•Source —
140 Storage Management Message Reference2180 The controller battery Learn cycle starts in %1 days. OK / Normal / InformationalCause: This alert is for
Storage Management Message Reference 1412183 Copyback failed on physical disk %1 from physical disk %2.Critical / Failure / ErrorCause: The physical d
142 Storage Management Message Reference2186 The controller cache has been discarded.Warning / Non-criticalCause: The controller has flushed the cache
Storage Management Message Reference 1432188 The controller write policy has been changed to Write Through.OK / Normal / InformationalCause: The contr
144 Storage Management Message Reference2190 The controller has detected a hot-add of an enclosure.OK / Normal / InformationalCause: This alert is for
Storage Management Message Reference 1452192 The virtual disk Check Consistency has made corrections and completed. OK / Normal / InformationalCause:
146 Storage Management Message Reference2195 Dedicated hot spare assigned. Physical disk %1OK / Normal / InformationalCause: This alert is for informa
Storage Management Message Reference 1472198 The physical disk is too small to be used for copyback.OK / Normal / InformationalCause: This alert is fo
148 Storage Management Message Reference2201 A global hot spare failed.Warning / Non-criticalCause: The controller is not able to communicate with a d
Storage Management Message Reference 1492203 A dedicated hot spare failed.Warning / Non-criticalCause: The controller is unable to communicate with a
Introduction 15Chassis location: <Name of chassis>Specifies name of the chassis that generated the message, for example:Chassis location: Main S
150 Storage Management Message Reference2205 A dedicated hot spare has been automatically unassigned.OK / Normal / InformationalCause: The hot spare i
Storage Management Message Reference 1512207 The only hot spare available is a SAS disk. SAS disks cannot replace SATA disks. Warning / Non-criticalCa
152 Storage Management Message Reference2211 The physical disk is not supported.Warning / Non-criticalCause: The physical disk may not have a supporte
Storage Management Message Reference 1532214 Battery charge in progressOK / Normal / InformationalCause: This alert is for informational purposes. Non
154 Storage Management Message Reference2218 None of the Controller Property are set.OK / Normal / InformationalCause: This alert is for informational
Storage Management Message Reference 1552222 Loadbalance and Auto Copyback on Predictive Failure changed.OK / Normal / InformationalCause: This alert
156 Storage Management Message Reference2226 Load balance changedOK / Normal / InformationalCause: This alert is for informational purposes. Action: C
Storage Management Message Reference 1572230 Auto Copyback on Predictive Failure changed.OK / Normal / InformationalCause: This alert is for informati
158 Storage Management Message Reference2234 The Patrol Read rate has changed.OK / Normal / InformationalCause: This alert is for informational purpos
Storage Management Message Reference 1592238 The controller debug log file has been exported.OK / Normal / InformationalCause: The user has attempted
16 IntroductionMemory device bank location: <Bank name in chassis>Specifies the name of the memory bank in the system that generated the message
160 Storage Management Message Reference2242 The Patrol Read operation has started.OK / Normal / InformationalCause: The controller has started the Pa
Storage Management Message Reference 1612245 A virtual disk blink has ceased.OK / Normal / InformationalCause: This alert is for informational purpose
162 Storage Management Message Reference2248 The controller battery is executing a Learn cycle.OK / Normal / InformationalCause: This alert is for inf
Storage Management Message Reference 1632252 The physical disk blink has ceased.OK / Normal / InformationalCause: This alert is for informational purp
164 Storage Management Message Reference2255 The physical disk has been started.OK / Normal / InformationalCause: This alert is for informational purp
Storage Management Message Reference 1652259 An enclosure blink operation has initiated.OK / Normal / InformationalCause: This alert is for informatio
166 Storage Management Message Reference2263 SMART thermal shutdown is disabled.OK / Normal / InformationalCause: This alert is for informational purp
Storage Management Message Reference 1672265 A device is in an unknown state.Warning / Non-criticalCause: The controller cannot communicate with a dev
168 Storage Management Message Reference2266 Controller log file entry: %1OK / Normal / InformationalCause: The %1 indicates a substitution variable.
Storage Management Message Reference 1692268 %1, Storage Management has lost communication with the con-troller. An immediate reboot is strongly recom
Introduction 17SD card device type: <Type of SD card device> Specifies the type of SD card device, for example:SD card device t
170 Storage Management Message Reference2270 The physical disk Clear operation failed.Critical / Failure / ErrorCause: A Clear task was being performe
Storage Management Message Reference 1712272 Patrol Read found an uncorrectable media error.Critical / Failure / ErrorCause: The Patrol Read task has
172 Storage Management Message Reference2273 A block on the physical disk has been punctured by the controller.Critical / Failure / ErrorCause: The co
Storage Management Message Reference 1732276 The dedicated hot spare is too small.Warning / Non-criticalCause: The dedicated hot spare is not large en
174 Storage Management Message Reference2278 The controller battery charge level is below anormal threshold.OK / Normal / InformationalCause: The batt
Storage Management Message Reference 1752280 A disk media error has been corrected.OK / Normal / InformationalCause: A disk media error was detected w
176 Storage Management Message Reference2282 Hot spare SMART polling failed.Critical / Failure / ErrorCause: The controller firmware attempted a SMART
Storage Management Message Reference 1772283 A redundant path is broken. Warning / Non-criticalCause: The controller has two connectors that are conne
178 Storage Management Message Reference2285 A disk media error was corrected during recovery.OK / Normal / InformationalCause: This alert is for info
Storage Management Message Reference 1792289 Multi-bit ECC error on controller DIMM. Critical / Failure / ErrorCause: An error involving multiple bits
18 Introduction
180 Storage Management Message Reference2290 Single-bit ECC error on controller DIMM. Warning / Non-criticalCause: An error involving a single bit has
Storage Management Message Reference 1812293 The EMM has failed.Critical / Failure / ErrorCause: The failure may be caused by a loss of power to the E
182 Storage Management Message Reference2296 An EMM has been inserted.OK / Normal / InformationalCause: This alert is for informational purposes. Acti
Storage Management Message Reference 1832299 Bad PHY %1 Critical / Failure / ErrorCause: There is a problem with a physical connection or PHY. The %1
184 Storage Management Message Reference2300 The enclosure is unstable.Critical / Failure / ErrorCause: The controller is not receiving a consistent r
Storage Management Message Reference 1852301 The enclosure has a hardware error.Critical / Failure / ErrorCause: The enclosure or an enclosure compone
186 Storage Management Message Reference2304 An attempt to hot plug an EMM has been detected. This type of hot plug is not supported.OK / Normal / Inf
Storage Management Message Reference 1872306 Bad block table is 80% full.Warning / Non-criticalCause: The bad block table is used for remapping bad di
188 Storage Management Message Reference2307 Bad block table is full. Unable to log block %1Critical / Failure / ErrorCause: The bad block table is us
Storage Management Message Reference 1892309 A physical disk is incompatible.Warning / Non-criticalCause: Yo u h a v e attempted to replace a disk w
Server Management Messages 192Server Management MessagesThe following tables lists in numerical order each event ID and its corresponding description,
190 Storage Management Message Reference2311 The firmware on the EMMs is not the same version. EMM0 %1 EMM1 %2Warning / Non-criticalCause: The firmwar
Storage Management Message Reference 1912313 A power supply in the enclosure has a DC failure.Warning / Non-criticalCause: The power supply has a DC f
192 Storage Management Message Reference2315 Diagnostic message %1OK / Normal / InformationalCause: The %1 indicates a substitution variable. The text
Storage Management Message Reference 1932318 Problems with the battery or the battery charger have been detected. The battery health is poor.Warning /
194 Storage Management Message Reference2320 Single-bit ECC error. The DIMM is critically degraded.Critical / Failure / ErrorCause: The DIMM is malfun
Storage Management Message Reference 1952322 The DC power supply is switched off.Critical / Failure / ErrorCause: The power supply unit is switched of
196 Storage Management Message Reference2324 The AC power supply cable has been removed.Critical / Failure / ErrorCause: The power cable may be pulled
Storage Management Message Reference 1972326 A foreign configuration has been detected.OK / Normal / InformationalCause: This alert is for information
198 Storage Management Message Reference2327 The NVRAM has corrupted data. The controller is reinitializing the NVRAM.Warning / Non-criticalCause: The
Storage Management Message Reference 1992329 SAS port report: %1Warning / Non-criticalCause: The text for this alert is generated by the controller an
Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potenti
20 Server Management Messages1003 A previously scheduled system BIOS update has been canceledInformation The user decides to cancel the flash BIOS upd
200 Storage Management Message Reference2330 SAS port report: %1OK / Normal / InformationalCause: The %1 indicates a substitution variable. The text f
Storage Management Message Reference 2012332 A controller hot plug has been detected.OK / Normal / InformationalCause: This alert is for informational
202 Storage Management Message Reference2335 Controller event log: %1Warning / Non-criticalCause: The %1 indicates a substitution variable. The text f
Storage Management Message Reference 2032336 Controller event log: %1Critical / Failure / ErrorCause: The %1 indicates a substitution variable. The te
204 Storage Management Message Reference2337 The controller is unable to recover cached data from the battery backup unit (BBU).Critical / Failure / E
Storage Management Message Reference 2052340 The BGI com-pleted with uncorrectable errors.Critical / Failure / ErrorCause: The BGI task encountered er
206 Storage Management Message Reference2342 The Check Consistency found inconsistent parity data. Data redundancy may be lost.Warning / Non-criticalC
Storage Management Message Reference 2072345 The virtual disk initialization failed. Critical / Failure / ErrorCause: The controller cannot communicat
208 Storage Management Message Reference2346 Error occurred: %1Warning / Non-criticalCause: A physical device may have an error. The %1 indicates a su
Storage Management Message Reference 2092347 The rebuild failed due to errors on the source physical disk.Critical / Failure / ErrorHardware RAID:Caus
Server Management Messages 211007 User initiated host system control actionAction requested was: <Action> Information User requested a host syst
210 Storage Management Message Reference2348 The rebuild failed due to errors on the target physical disk.Critical / Failure / ErrorCause: Yo u a r e
Storage Management Message Reference 2112351 A physical disk is marked as missing.OK / Normal / InformationalCause: This alert is for informational pu
212 Storage Management Message Reference2354 Enclosure firmware download in progress.OK / Normal / InformationalCause: This alert is provided for info
Storage Management Message Reference 2132355 Cont.Action: Attempt to download the enclosure firmware again. If problems continue, verify that the cont
214 Storage Management Message Reference2356 SAS SMP communications error %1Critical / Failure / ErrorCause: The text for this alert is generated by t
Storage Management Message Reference 2152357 SAS expander error: %1Critical / Failure / ErrorCause: The %1 indicates a substitution variable. The text
216 Storage Management Message Reference2359 The physical disk is not certified.Warning / Non-criticalCause: The physical disk does not comply with th
Storage Management Message Reference 2172362 Physical disk(s) have been removed from a virtual disk. The virtual disk is in Failed state during the ne
218 Storage Management Message Reference2367 Rebuild is not possible because mixing of different media type (SSD/HDD) and bus protocols (SATA/SAS) is
Storage Management Message Reference 2192369 Virtual Disk Redundancy has been degraded.OK / Normal / InformationalCause: A physical disk in a RAID 6 v
22 Server Management MessagesTemperature Sensor MessagesThe temperature sensors listed in Table 2-2 help protect critical components by alerting the s
220 Storage Management Message Reference2372 Attempted import of Virtual Disk exceeding the limit supported on the controller.OK / Normal / Informatio
Storage Management Message Reference 2212376 Attempted import of Virtual Disk with stale physical diskOK / Normal / InformationalCause: User is attemp
222 Storage Management Message Reference2380 Foreign configuration has been partially imported. Some configuration failed to import.OK / Normal / Info
Storage Management Message Reference 2232381 Controller preserved cache is recovered.OK / Normal / InformationalCause: This alert is provided for info
224 Storage Management Message Reference2384 The Warning level set for the hot spare protection policy is violated for the Virtual Disk.Warning / Non-
Storage Management Message Reference 2252387 A virtual disk bad block medium error is detected.Critical / Failure / ErrorCause: Virtual disk bad block
226 Storage Management Message Reference2387 contd.2To clear these bad blocks, execute the Clear Virtual Disk Bad Blocks task.3Run Patrol Read to ensu
Storage Management Message Reference 2272392 The drive Encryption Key is invalid.Warning / Non-criticalCause: The controller failed to verify the spec
228 Storage Management Message Reference2396 The Check Consistency detected uncorrectable multiple medium errorsCritical / Failure / ErrorCause: The C
Storage Management Message Reference 2292399 The Physical Disk Power status changed from 1% to 2%OK / Normal / InformationalCause: The physical disk p
Server Management Messages 23Table 2-2. Temperature Sensor MessagesEvent IDDescription Severity Cause1050 Temperature sensor has failedSensor location
230 Storage Management Message Reference2403 Virtual Disk is availableOK / Normal / InformationalCause: The operating system detects the newly created
Storage Management Message Reference 2312407 Controller Encryption mode is enabled in LKMInformational Cause: The Local Key Management (LKM) encryptio
232 Storage Management Message Reference2414 Controller CacheCade is deletedInformational Cause: This alert is provided for informational purposes.Act
Storage Management Message Reference 2332417 There is an unrecoverable medium error detected on virtual diskCritical / Failure / Error Cause: Unrecove
234 Storage Management Message Reference2417 cntd.NOTE: If the unrecoverable medium error has not been corrected, it may be reported again by the syst
Storage Management Message Reference 2352426 State change on Physical disk from Non-RAID to READY.Informational Cause: User triggered action.Action: C
236 Storage Management Message Reference2432 The PCIeSSD device was found to be in security locked state. Full initialization has to be done on the se
Storage Management Message Reference 2372702 The following journal mirror has failed.(wwn) %1 : FluidCacheWarning No action required. Clear Alert: No
238 Storage Management Message Reference2874 The following Cache Device has no associated server in the configuration: %1 : FluidCacheWarning There is
Storage Management Message Reference 2392901 The following storage device is either inaccessible or failed.(wwn) %1 (path) %2 : FluidCacheError If the
24 Server Management Messages1052 Temperature sensor returned to a normal valueSensor location: <Location in chassis>Chassis location: <Name
240 Storage Management Message Reference2905 The following cache device is being removed.(wwn) %1 (path) %2 : FluidCacheInformation No action required
Storage Management Message Reference 2412909 The following storage device is in an unknown state.(wwn) %1 (path) %2 : FluidCacheWarning Service is req
242 Storage Management Message Reference2913 The following failed cache device has completed recovery.(wwn) %1 (path) %2 : FluidCacheInformation No ac
Storage Management Message Reference 2432917 Running on an expired evaluation license. No configuration changes will be allowed. Expired days: % 1: Fl
244 Storage Management Message Reference2921 A license has been removed.: FluidCacheInformation A license should be installedClear Alert: None Related
Storage Management Message Reference 2452930 Even though caching was enabled in write-back mode, it is currently operating in write-through mode.: Flu
246 Storage Management Message Reference2933 Caching is no longer degraded to pass-through mode and is now operating in its configured mode.: FluidCac
System Event Log Messages for IPMI Systems 2474System Event Log Messages for IPMI SystemsThe tables in this chapter list the system event log (SEL) me
248 System Event Log Messages for IPMI Systems<Sensor Name/Location> temperature sensor returned to warning state <Reading>.Warning Temper
System Event Log Messages for IPMI Systems 249Voltage Sensor EventsThe voltage sensor event messages monitor the number of volts across critical compo
Server Management Messages 251054 Temperature sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Name of
250 System Event Log Messages for IPMI Systems<Sensor Name/Location> voltage sensor detected a warning <Reading>.Warning Voltage of the mo
System Event Log Messages for IPMI Systems 251Fan Sensor EventsThe cooling device sensors monitor how well a fan is functioning. These messages provid
252 System Event Log Messages for IPMI Systems<Sensor Name/Location> Fan Redundancy sensor redundancy regainedInformation The fan specified by &
System Event Log Messages for IPMI Systems 253Processor Status EventsThe processor status messages monitor the functionality of the processors in a sy
254 System Event Log Messages for IPMI Systems<Processor Entity> status processor sensor terminator not present.Information This event is genera
System Event Log Messages for IPMI Systems 255Power Supply EventsThe power supply sensors monitor the functionality of the power supplies. These messa
256 System Event Log Messages for IPMI Systems<Power Supply Sensor Name> power supply sensor returned to normal state.Information This event is
System Event Log Messages for IPMI Systems 257PS 1 Status: Power supply sensor for PS 1, failure was assertedCritical This event is generated when the
258 System Event Log Messages for IPMI SystemsA predictive failure detected on power supply <number>.Warning This event is generated when the po
System Event Log Messages for IPMI Systems 259An over current fault detected on power supply <number>.Critical The specified power supply detect
26 Server Management MessagesCooling Device MessagesThe cooling device sensors listed in Table 2-3 monitor how well a fan is functioning. Cooling devi
260 System Event Log Messages for IPMI SystemsMemory ECC EventsThe memory ECC event messages monitor the memory modules in a system. These messages mo
System Event Log Messages for IPMI Systems 261BMC Watchdog EventsThe BMC watchdog operations are performed when the system hangs or crashes. These mes
262 System Event Log Messages for IPMI SystemsMemory EventsThe memory modules can be configured in different ways in particular systems. These message
System Event Log Messages for IPMI Systems 263Memory Mirrored redundancy degraded.Warning This event is generated when there is a memory failure in a
264 System Event Log Messages for IPMI SystemsHardware Log Sensor EventsThe hardware logs provide hardware status messages to the system management so
System Event Log Messages for IPMI Systems 265Drive EventsThe drive event messages monitor the health of the drives in a system. These events are gene
266 System Event Log Messages for IPMI SystemsDrive <Drive #>hot spare was deassertedInformational This event is generated when the drive is tak
System Event Log Messages for IPMI Systems 267Intrusion EventsThe chassis intrusion messages are a security measure. Chassis intrusion alerts are gene
268 System Event Log Messages for IPMI SystemsBIOS Generated System EventsThe BIOS-generated messages monitor the health and functionality of the chip
System Event Log Messages for IPMI Systems 269System Event PCIE Fatal Err.Critical This error is generated when a fatal error is detected on the PCIE
Server Management Messages 271102 Fan sensor returned to a normal valueSensor location: <Location in chassis>Chassis location: <Name of chass
270 System Event Log Messages for IPMI SystemsMemory Add(BANK# DIMM#) presence was assertedInformation This event is generated when memory is added to
System Event Log Messages for IPMI Systems 271USB Over-currenttransition to non-recoverableCritical This event is generated when the USB exceeds a pre
272 System Event Log Messages for IPMI SystemsLinkT/FlexAddr: Link Tuning sensor, device option ROM failed to support link tuning or flex address (Mez
System Event Log Messages for IPMI Systems 273A PCI system error was detected on a component at bus <number> device <number> function <
274 System Event Log Messages for IPMI SystemsA fatal IO error detected on a component at bus <number> device <number> function <number
System Event Log Messages for IPMI Systems 275Memory device at location <location> is overheating.Critical This event is generated when system m
276 System Event Log Messages for IPMI SystemsA hardware incompatibility detected between BMC/iDRAC firmware and CPU.Critical This event is generated
System Event Log Messages for IPMI Systems 277POST Code TableTable 4-13 lists the POST Code errors that are generated when a fatal error occurs during
278 System Event Log Messages for IPMI SystemsOperating System Generated System EventsC0 Shutdown test failure This error code indicates a shutdown te
System Event Log Messages for IPMI Systems 279Cable Interconnect EventsThe cable interconnect messages in Table 4-15 are used for detecting errors in
28 Server Management Messages1105 Fan sensor detected a non-recoverable valueSensor location: <Location in chassis>Chassis location: <Name of
280 System Event Log Messages for IPMI SystemsBattery EventsTable 4-16. Battery EventsDescription Severity Cause<Battery sensor Name/Location>Fa
System Event Log Messages for IPMI Systems 281Power And Performance EventsThe power and performance events are used to detect degradation in system pe
282 System Event Log Messages for IPMI SystemsSystem Board Power Optimized: Performance status sensor for System Board, degraded, user defined power c
System Event Log Messages for IPMI Systems 283The system performance degraded because of thermal protection.Warning This event is generated when a cha
284 System Event Log Messages for IPMI SystemsEntity Presence EventsThe entity presence messages are used for detecting different hardware devices.The
System Event Log Messages for IPMI Systems 285MiscellaneousThe following table provides events related to hardware and software components like mezzan
286 System Event Log Messages for IPMI SystemsHdwar version err: Version Change sensor, hardware incompatibility (BMC firmware and CPU mismatch) was a
System Event Log Messages for IPMI Systems 287LinkT/FlexAddr: Link Tuning sensor, failed to get link tuning or flex address data from BMC/iDRAC was as
288 System Event Log Messages for IPMI SystemsBIOS Authenticated Code Module detected an Intel Trusted Execution Technology (TXT) error during POST.Cr
Index 289IndexAAC power cord messages, 49AC power cord sensor, 9AC power cord sensor has failed, 265Asset name changed, 124Asset tag changed, 124BBack
Server Management Messages 29Voltage Sensor MessagesThe voltage sensors listed in Table 2-4 monitor the number of volts across critical components. Vo
290 IndexEEnclosure alarm, 120Enclosure firmware mismatch, 107entity presence messages, 281Error occurred%1, 208event description reference, 14Ffan en
Index 291fan sensor, 251hardware log sensor, 264intrusion, 267memory device, 46memory ECC, 260memory modules, 262pluggable device, 55, 268power supply
292 Indextemperature, 9voltage, 9Service tag changed, 125Single-bit ECC error limit, 142Single-bit ECC error., 180SMART thermal shutdown, 165Smart war
Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . 7What’s New in this Release . . . . . . . . . . . . . . . . 8Messag
30 Server Management Messages1152 Voltage sensor returned to a normal valueSensor location: <Location in chassis>Chassis location: <Name of c
Server Management Messages 311154 Voltage sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Name of cha
32 Server Management MessagesCurrent Sensor MessagesThe current sensors listed in Table 2-5 measure the amount of current (in amperes) that is travers
Server Management Messages 331201 Current sensor value unknownSensor location: <Location in chassis>Chassis location: <Name of chassis>Pre
34 Server Management Messages1203 Current sensor detected a warning valueSensor location: <Location in chassis>Chassis location: <Name of cha
Server Management Messages 35Chassis Intrusion MessagesThe chassis intrusion messages listed in Table 2-6 are a security measure. Chassis intrusion me
36 Server Management MessagesTable 2-6. Chassis Intrusion MessagesEvent IDDescription Severity Cause1250 Chassis intrusion sensor has failedSensor loc
Server Management Messages 371253 Chassis intrusion in progressSensor location: <Location in chassis>Chassis location: <Name of chassis>Pr
38 Server Management MessagesRedundancy Unit MessagesRedundancy means that a system chassis has more than one of certain critical components. Fans and
Server Management Messages 391302 Redundancy not applicableRedundancy unit: <Redundancy location in chassis>Chassis location: <Name of chassi
4 ContentsChassis Intrusion Messages . . . . . . . . . . . . . . 35Redundancy Unit Messages. . . . . . . . . . . . . . . 38Power Supply Messages
40 Server Management Messages1304 Redundancy regainedRedundancy unit: <Redundancy location in chassis>Chassis location: <Name of chassis>P
Server Management Messages 411306 Redundancy lostRedundancy unit: <Redundancy location in chassis>Chassis location: <Name of chassis>Previ
42 Server Management MessagesPower Supply MessagesThe power supply sensors monitor how well a power supply is functioning. The power supply messages l
Server Management Messages 431351 Power supply sensor value unknownSensor location: <Location in chassis>Chassis location: <Name of chassis&g
44 Server Management Messages1353 Power supply detected a warning Sensor location: <Location in chassis>Chassis location: <Name of chassis>
Server Management Messages 451355 Power supply sensor detected a non-recoverable valueSensor location: <Location in chassis>Chassis location: &l
46 Server Management MessagesMemory Device MessagesThe memory device messages listed in Table 2-9 provide status and warning information for memory mo
Server Management Messages 47Fan Enclosure MessagesSome systems are equipped with a protective enclosure for fans. Fan enclosure messages listed in Ta
48 Server Management Messages1454 Fan enclosure removed from system for an extended amount of timeSensor location: <Location in chassis>Chassis
Server Management Messages 49AC Power Cord MessagesThe AC power cord messages listed in Table 2-11 provide status and warning information for power co
Contents 5Voltage Sensor Events . . . . . . . . . . . . . . . . . 249Fan Sensor Events. . . . . . . . . . . . . . . . . . . . 251Processor Status E
50 Server Management MessagesHardware Log Sensor MessagesThe hardware logs provide hardware status messages to systems management software. On certain
Server Management Messages 51Table 2-12. Hardware Log Sensor MessagesEvent IDDescription Severity Cause1550 Log monitoring has been disabledLog type:
52 Server Management MessagesProcessor Sensor MessagesThe processor sensors monitor how well a processor is functioning. Processor messages listed in
Server Management Messages 531602 Processor sensor returned to a normal valueSensor Location: <Location in chassis>Chassis Location: <Name of
54 Server Management Messages1604 Processor sensor detected a failure valueSensor Location: <Location in chassis>Chassis Location: <Name of c
Server Management Messages 55Pluggable Device MessagesThe pluggable device messages listed in Table 2-14 provide status and error information when som
56 Server Management Messages1652 Device removed from systemDevice location: <Location in chassis>Chassis location: <Name of chassis>Addit
Server Management Messages 57Battery Sensor MessagesThe battery sensors monitor how well a battery is functioning. The battery messages listed in Tabl
58 Server Management Messages1702 Battery sensor returned to a normal valueSensor Location: <Location in chassis>Chassis Location: <Name of c
Server Management Messages 59Secure Digital (SD) Card Device MessagesThe SD card device sensors monitor instrumented SD card devices in the system. Ta
6 Contents
60 Server Management Messages1751 SD card device sensor value unknownSensor location: <Location in chassis>Chassis location: <Name of chassis
Server Management Messages 611753 SD card device detected a warningSensor location: <Location in chassis>Chassis location: <Name of chassis&g
62 Server Management Messages1755 SD card device sensor detected a non-recoverable valueSensor location: <Location in chassis>Chassis location:
Server Management Messages 63Chassis Management Controller MessagesThe Alerts sent by Dell M1000e Chassis Management Controller (CMC) are organized by
64 Server Management Messages
Storage Management Message Reference 653Storage Management Message ReferenceThe Dell OpenManage Server Administrator Storage Management’s alert or eve
66 Storage Management Message ReferenceAlert Message Format with Substitution Variables When you view an alert in the Server Administrator alert log,
Storage Management Message Reference 67 NOTE: A, B, C and X, Y, Z in the following examples are variables representing the storage object name or num
68 Storage Management Message ReferenceSAS Power SupplyMessage Format: Power Supply X Controller A, Connector B, Enclosure CFor example, 2312 A power
Storage Management Message Reference 69Alert Message Change HistoryThe following table describes the changes made to the Storage Management alerts fro
Introduction 71IntroductionDell OpenManage Server Administrator generates event messages stored primarily in the operating system or Server Administra
70 Storage Management Message ReferenceAlert Descriptions and Corrective ActionsThe following sections describe alerts generated by the RAID or SCSI c
Storage Management Message Reference 71traps for these alerts use all of the SNMP trap variables. For more information on SNMP support and the MIB, se
72 Storage Management Message Reference2049 Physical disk removedWarning / Non-criticalCause: A physical disk has been removed from the disk group. Th
Storage Management Message Reference 732050 Physical disk offlineWarning / Non-criticalCause: A physical disk in the disk group is offline. The user m
74 Storage Management Message Reference2052 Physical disk insertedOK / Normal / InformationalCause: This alert is for informational purposes. Action:
Storage Management Message Reference 752056 Virtual disk failedCritical / Failure / ErrorCause: One or more physical disks included in the virtual dis
76 Storage Management Message Reference2057 Virtual disk degradedWarning / Non-criticalCause 1: This alert message occurs when a physical disk include
Storage Management Message Reference 772057 contd.Cause 2: A physical disk in the disk group has been removed.Action 2: If a physical disk was removed
78 Storage Management Message Reference2060 Copy of data started from physical disk %2 to physical disk %1.OK / Normal /InformationalCause: This alert
Storage Management Message Reference 792063 Virtual disk reconfiguration startedOK / Normal / InformationalCause: This alert is for informational purp
8 IntroductionWhat’s New in this ReleaseNew Alert messages for Fluid cache for DAS. Messages Not Described in This GuideThis guide describes only even
80 Storage Management Message Reference2067 Virtual disk check consistency cancelledOK / Normal / InformationalCause: The check consistency operation
Storage Management Message Reference 812070 Virtual disk initialization cancelledOK / Normal / InformationalCause: The virtual disk initialization can
82 Storage Management Message Reference2075 Copy of data completed from physical disk %2 to physical disk %1.OK / Normal / InformationalCause: This al
Storage Management Message Reference 832077 Virtual disk format failed.Critical / Failure / ErrorCause: A physical disk included in the virtual disk f
84 Storage Management Message Reference2080 Physical disk initialization failedCritical / Failure / ErrorCause: The physical disk has failed or is not
Storage Management Message Reference 852081 contd.Software RAID:•Perform a backup with the Verify option. • If the file backup fails, try to restore t
86 Storage Management Message Reference2083 Physical disk rebuild failedCritical / Failure / ErrorCause: A physical disk included in the virtual disk
Storage Management Message Reference 872086 Virtual disk format completedOK / Normal / InformationalCause: This alert is for informational purposes. A
88 Storage Management Message Reference2088 Virtual disk initialization completedOK / Normal / InformationalCause: This alert is for informational pur
Storage Management Message Reference 892090Virtual disk reconfiguration completedOK / Normal / InformationalCause: This alert is for informational pur
Introduction 9Server Administrator generates events based on status changes in the following sensors:•Temperature Sensor — Helps protect critical comp
90 Storage Management Message Reference2092 Physical disk rebuild completedOK / Normal / InformationalCause: This alert is for informational purposes.
Storage Management Message Reference 912094 Predictive Failure reported. Warning / Non-criticalCause: The physical disk is predicted to fail. Many phy
92 Storage Management Message Reference2094 cond.If this disk is a hot spare, then unassign the hot spare; perform the Prepare to Remove task on the d
Storage Management Message Reference 932099 Global hot spare unassignedOK / Normal / InformationalCause: A physical disk that was assigned as a hot sp
94 Storage Management Message Reference2099 Cont.Action: Although this alert is provided for informational purposes, you may need to assign a new hot
Storage Management Message Reference 952101 Temperature dropped below the minimum warning thresholdWarning / Non-criticalCause: The physical disk encl
96 Storage Management Message Reference2102 Temperature exceeded the maximum failure thresholdCritical / Failure / ErrorCause: The physical disk enclo
Storage Management Message Reference 972103 Temperature dropped below the minimum failure threshold Critical / Failure / ErrorCause: The physical disk
98 Storage Management Message Reference2106 SMART FPT exceededWarning / Non-criticalCause: A disk on the specified controller has received a SMART ale
Storage Management Message Reference 992107 SMART configuration changeCritical / Failure / ErrorCause: A disk has received a SMART alert (predictive f
Komentarze do niniejszej Instrukcji