omconfig: Managing Components Using the Instrumentation Service 103
To enable broadcast messages if a current probe detects a failure event, type:
omconfig system alertaction event=currentfail
broadcast=true
or
omconfig servermodule alertaction event=
currentfail broadcast=true
Example Fan Probe Actions
To generate alerts when a fan probe detects a failure value, type:
omconfig system alertaction event=fanfail alert=
true
or
omconfig servermodule alertaction event=fanfail
alert=true
Example Chassis Intrusion Actions
To clear all alert actions for chassis intrusion, type:
omconfig system alertaction event=intrusion
clearall=true
or
omconfig servermodule alertaction event=intrusion
clearall=true
Commands for Clearing Logs
NOTE: For more information about alert messages, see the Dell OpenManage
Server Administrator Messages Reference Guide.
You can use the omconfig system or omconfig servermodule command to
clear three logs: the alert log, the command log, and the hardware or ESM log.
To clear the contents of the alert log, type:
omconfig system alertlog action=clear
or
omconfig servermodule alertlog action=clear
NOTE: Entering an invalid RAC user name may prevent the command log from
displaying. Clearing the command log resolves this condition.