134 Using the Storage Management Service
omreport Global Information (Smart Thermal Shutdown Status)
Table 6-5 describes the syntax for the omreport Global Information
Commands.
omreport Battery Status
Table 6-6 describes the syntax for the omreport Battery Commands.
Table 6-5. omreport Global Information Commands
Required Command Levels
(1, 2, 3)
Optional name=
value pairs
Use
omreport storage globalinfo Displays whether smart thermal shutdown is
enabled or disabled. See the "omconfig Global
Enable Smart Thermal Shutdown" command
for more information.
Table 6-6. omreport Battery Commands
Required Command Levels (1, 2, 3) Optional name=value pairs Use
omreport storage battery Displays all batteries present on all
controllers on the system. (Some
controllers do not have batteries).
controller=id
where id is the controller
number. For example:
controller=0
Displays the battery on the
specified controller.