Przeglądanie stron 196
Thermal Group 197
Temperature Probe Upper Noncritical Threshold
Temperature Probe Lower Noncritical Threshold
Temperature Probe Lower Critical Threshold
Temperature Probe Lower Nonrecoverable Threshold
Name temperatureProbeUpperNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.11
Description Defines the user-assigned value of the temperature probe’s
upper noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write
Name temperatureProbeLowerNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12
Description Defines the user-assigned value of the temperature probe’s
lower noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write
Name temperatureProbeLowerCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.13
Description Defines the value of the temperature probe’s lower critical threshold.
Syntax DellSigned32BitRange
Access Read-only
Name temperatureProbeLowerNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.14
Description Defines the value of the temperature probe’s lower
nonrecoverable threshold.
Syntax DellSigned32BitRange
Access Read-only