Strona 1 - 1.50.50 and CMC 4.5

RACADM Command Line Reference Guide for iDRAC7 1.50.50 and CMC 4.5

Strona 3 - Contents

ff00::/8 :: U 256 0 0 ethlKernel IP routing tableDestinationGateway Genmask Flags MSS Window irtt Iface10.94.161.00.0.0.0 255.255.255.0U 0 0 0 bond00.

Strona 4

• Displays the statistics for the integrated NIC.$ racadm nicstatistics NIC.Integrated.1-1Total Bytes Received:0Total Bytes Transmitted:

Strona 5

Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Ping statist

Strona 6

Active CMC Version = X08Standby CMC Version = N/ALast Firmware Update = Wed Nov 21 21:37:56 2007Hardware Version = 2Current IP Addr

Strona 7

racresetDescription Resets iDRAC. The reset event is logged in the iDRAC log.Resets CMC. The reset event is logged in the hardware (SEL) and CMC (RAC)

Strona 8

• To reset CMC.racadm racreset• To reset server 1.racadm racreset -m server-1• To reset servers 1 and 3.racadm racreset -m server-1 server-3racresetcf

Strona 9

Example• Reset the configuration on iDRAC.racadm racresetcfgThe RAC configuration has initiated restoration to factory defaults.Wait up to a minute fo

Strona 10

• To generate and view information about the inventory of virtual disks.raid get vdisksracadm raid get vdisks --refkey <controller FQDDs separated

Strona 11 - Introduction

64k|128k|256k|512k|1M|2M|4M|8M|16M}]-pdkey:<comma separated PD FQDD> [-dcp {enabled|disabled|default}] [-name <VD name>] [-size <VD siz

Strona 12 - RACADM Syntax Usage

– disabled — Does not allow the virtual disk to use the cache.– default — Uses the default cache policy. For SAS drives, use the disabled option and f

Strona 13 - Remote RACADM

1IntroductionThis document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object def

Strona 14 - RACADM Command Options

ReconstructRate = 30 % PatrolReadRate = 30 % PatrolReadMode = Automatic PatrolReadState

Strona 15

This command displays all battery keys connected to the controllers.racadm raid get batteries --refkey RAID.Integrated.1-1Battery.Integrated.1:RAID.In

Strona 16 - Supported RACADM Subcommands

FailurePredicted = NORemainingRatedWriteEndurance = Not ApplicableSecurityStatus = Not CapableBusProtocol

Strona 17

ManufacturedYear = 2012SasAddress = 0x5000C5005952386DFormFactor = 2.5 InchRaidNominalMedi

Strona 18

– This command deletes the specified virtual disk.racadm raid deletevd:Disk.Virtual.0:RAID.Integrated.1-1– This command encrypts the specified virtual

Strona 19

• -u — User name to access the network share.• -p — Password to access the network share.• -l — Image location on the network share; use double quotat

Strona 20 - Other Documents You May Need

rollbackDescription Allows you to roll back the firmware to an earlier version.Synopsisracadm rollback <FQDD>NOTE: To get the list of available

Strona 21 - Contacting Dell

NOTE: The actionpowerstatus is not allowed with -a option.Output Displays an error message if the requested operation is not completed, or a success m

Strona 22

NOTE: • For configuration of staged objects such as BIOS or NIC, commit and reboot job creation must be used to apply the pending values. For more inf

Strona 23 - RACADM Subcommand Details

Output• Object value modified successfully• Unsuccessful message indicating reason for the same.Example• Configure the iDRAC using a file.$ racadm set

Strona 24

– Reset, clear, and import the RAID configuration to the controller.• Manage the properties of the ISM modules using the objects in the iDRAC.ServiceM

Strona 25

– 1 — to use existing groupNOTE: If —e is 0, then admin password is mandatory.• <groupName> — Name of the group for administrative purpose. You

Strona 26

Example• racadm setassettag -m chassis 783839–33• racadm setassettag 783839–33The asset tag was changed successfully.setchassisnameDescription Sets th

Strona 27

• Disable flex address for fabric iDRAC.racadm setflexaddr -f idrac 0setledDescription Sets the state (blinking or not blinking) of the LED on the spe

Strona 28

setniccfgDescription Sets the iDRAC IP address. It displays an error message if the requested operation could not be performed. A success message is d

Strona 29

NOTE: • -o, -k, -p: These options can be specified for chassis only• -6: Sets static IPv6 addresses(w/ -soption). Enables autoconfig for IPv6(w/-d opt

Strona 30

– mmmmmm is the number of microseconds– s is a + (plus) sign or a − (minus) sign, which indicates the sign of the offset.– off is the offset in minute

Strona 31

NOTE: The OMSA server agent must be present and running on the server to use the Display Hostname feature. If the agent is not running, the setting is

Strona 32 - User Guide

Telnet/SSH/serial RACADM:racadm sshpkauth -i <2 to 16> -k <1 to 4> -t<key-text>ViewThe view mode allows the user to view a user-spec

Strona 33

wilU2VLw/iRH1ZymUFnut8ggbPQgqV2L8bsUaMqb5PooIIvV6hy4isCNJU=1024-bit RSA, converted from OpenSSH by [email protected] ID 2:Key ID 3:Key ID

Strona 34

– –1=Base64– –2=PKCS12The current release does not support this option.• -p — Pass phrase for decrypting the PKCS12 file uploaded.• -k — Filename of t

Strona 35

Local RACADMracadm getconfig -g <groupname> [-o <objectname>][-i <indexnumber>]racadm <subcommand>Exampleracadm getconfig -g i

Strona 36

State (S) TexasLocality (L)Round RockOrganization (O)Dell Inc.Organizational Unit (OU)Remote Access GroupCommon Name (CN)iDRAC7 Default certificateIss

Strona 37

racadm sslcertview -t 1 -A00USTexasRound RockDell Inc.Remote Access GroupiDRAC7 default certificateUSTexasRound RockDell Inc.Remote Access GroupiDRAC7

Strona 38

Input• -g — Generates a new CSR.• -s — Returns the status of a CSR generation process (generation in progress, active, or none).• -f — Specifies the f

Strona 39

Example$ racadm sslresetcfgCertificate generated successfully and webserver restarted.NOTE: For more information about managing SSL certificates, see

Strona 40

NOTE: • To run this subcommand, you require the Server Profile Export and Import license.• Backup operation is licensed but restore operation is not l

Strona 41

NOTE: The -dom, -wom, or -dow option must be included in the command for the autoupdate schedule. The * value for the options must be included within

Strona 42

– AutoBackup system to NFS share and encrypt the data.racadm systemconfig backup -f image.img -l 192.168.2.140:/share -u admin -p passwd -n encryptpas

Strona 43

Input• -f <feature> — options are:– AD — Test AD using simple authentication– ADKRB — Test AD using Kerberos authentication– LDAP — Test Generic

Strona 44

ExampleCommands for the cfgIpmiPet group:• Enable the alert.racadm config -g cfgIpmiPet -o cfgIpmiPetAlertEnable -i 1 • Set the destination email IP a

Strona 45

traceroute6Description Traces the network path of routers as the packets traverse from the system to a destination IPv6 address.To run this subcommand

Strona 46

VLanMode = DisabledWakeOnLan = Disabled• To display a single attribute for the specified group, run:racadm get device.<group name>.

Strona 47

For update from repository .xml files are allowed.If a file name is not specified for repository update, then the Catalog.xml is taken as default.• -u

Strona 48

• Upload the update file from a remote NFS share.racadm update -f <updatefile> -l 1.2.3.4:/share• Upload the update file from the local file sys

Strona 49

usercertviewDescription Displays the user certificate or user CA certificate that exists on iDRAC.This subcommand is applicable only for iDRAC.Synopsi

Strona 50

NOTE: • To run this subcommand, you must have the iDRAC7 Enterprise license.• After iDRAC restart, the status of the previous operation performed on t

Strona 51

NOTE: – This feature is not supported in Local RACADM.– Creating vFlash partition from an image file on the CFS or NFS IPv6 enabled network share is n

Strona 52

3iDRAC and CMC Property Database Group and Object DescriptionsThe iDRAC and CMC property database contains the configuration information for iDRAC and

Strona 53

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower ServersCMCcfgRacSecurity No No YescfgRacVirtual Yes Yes NocfgServerInfo No Yes YescfgActiveD

Strona 54

The following sections provide information about the objects in the idRACInfo group.idRacProductInfo (Read Only)DescriptionA text string that identifi

Strona 55

iDRAC Type (Read Only)DescriptionIdentifies the remote access controller type.Legal ValuesProduct IDDefault For CMC: 9For 10G iDRAC: 8For 11G iDRAC6 o

Strona 56

cfgNicIPv4Enable (Read or Write)DescriptionEnables or disables iDRAC or CMC IPv4 stack.Legal Values• 1 (TRUE)• 0 (FALSE)Default0cfgNicSelection (Read

Strona 57

Using The Autocomplete FeatureUse the autocomplete feature to:• Display all the available RACADM commands in the alphabetical order on pressing the &l

Strona 58

NOTE: For iDRAC Enterprise on Blade Servers, this object enables or disables the VLAN capabilities of iDRAC from CMC.Read only for iDRAC on Blade serv

Strona 59

Default0For CMC, this property is used only if cfgNicUseDhcp is set to 1(true), or if both cfgIPv6Enable and cfgIPv6AutoConfig are set to 1(true).The

Strona 60

NOTE: For IPv6, only the DHCPv6 address or static address is registered.Example:racadm getconfig -g cfgLanNetworkingcfgNicEnable=1cfgNicIPv4Enable=1cf

Strona 61

cfgDNSServer2 (Read or Write)DescriptionRetrieves the IPv4 address for DNS server 2. This parameter is only valid if cfgDNSServersFromDHCP is set to 0

Strona 62

cfgNicGateway (Read or Write)DescriptioniDRAC or CMC gateway IPv4 address.The gateway IPv4 address used for static assignment of the RAC IP address. T

Strona 63

cfgNicStaticIPv4Enable (Read or Write)DescriptionEnables or disables the IPv4 stack.Legal Values• 0 — Disabled• 1 — EnabledDefault1 — EnabledNOTE: If

Strona 64

cfgDNSStaticServersFromDHCP (Read or Write)DescriptionSpecifies the DNS server static IP addresses.Legal Values• DNS Addresses are configured on the D

Strona 65

cfgRemoteHostsThis group provides properties that allow configuration of the SMTP server for email alerts.For CMC, this group enables/disables and con

Strona 66

cfgRhostsNtpEnableDescription Enables or disables the use of the Network Time Protocol (NTP) for date and time synchronization.This object is applicab

Strona 67

cfgRhostsSyslogEnable (Read or Write)DescriptionTo allow the RAC and SEL logs to be written to up to three remote syslog servers Enables or disables r

Strona 68

setledsetniccfgsshpkauthsslcertviewsslcertdeletesslcsrgensslEncryptionStrengthsslkeyuploadsslresetcfgswinventorysystemconfigtestemailtesttraptestalert

Strona 69

Default<blank>cfgRhostsSyslogPowerLoggingEnabledDescription To remote syslog servers, Enables or disables power consumption logging.This object

Strona 70

NOTE: In the current CMC firmware version, the objects cfgUserAdminEnable and cfgUserAdminPrivilege are interrelated; changing the value of one proper

Strona 71

Exampleracadm getconfig -g cfgUserAdmin -i 1# cfgUserAdminIndex=1cfgUserAdminEnable=1cfgUserAdminUserName=root# cfgUserAdminPassword=******** (Write-O

Strona 72

Fabric A Administrator0x0000200Fabric B Administrator0x0000400Fabric C Administrator0x0000800ExamplesThe following table provides sample privilege bit

Strona 73

cfgUserAdminPassword (Write Only)DescriptionThe password for this user. User passwords are encrypted and cannot be seen or displayed after the propert

Strona 74

cfgEmailAlertThis group contains parameters to configure iDRAC or CMC email alerting capabilities. Up to four instances of this group are allowed.Use

Strona 75

This object property is specific to CMC.Legal ValuesA string of up to 32 charactersDefault<blank>Exampleracadm getconfig -g cfgEmailAlert -i 2#

Strona 76

An expired web server session logs out the current session.Legal Values60–10800Default1800cfgSsnMgtSshIdleTimeout (Read or Write)DescriptionDefines th

Strona 77

• For iDRAC Enterprise on Blade Servers and CMC: 1800cfgSerialThis group contains configuration parameters for iDRAC or CMC services. One instance of

Strona 78

For CMC:This key specifies the character that ends the serial text console connect (or racadm connect) command.NOTE: The CTRL key is represented by us

Strona 79

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMCTelnet/SSH/SerialLocal RACADMRemote RACADMTelnet/SSH/SerialLocal RACADMRemote RAC

Strona 80 - Host name

cfgSerialConsoleColumnsDescriptionSpecifies the number of columns in the terminal window command line connected to the serial port. To take effect log

Strona 81

cfgSerialHistorySize=8192cfgSerialTelnetEnable=0cfgSerialSshEnable=1cfgSerialTelnetEnable (Read or Write) DescriptionEnables or disables the Telnet co

Strona 82

cfgTrapsThis group displays information for and configures delivery of SNMP traps for a specific user.This group is applicable only for CMC. Use this

Strona 83

cfgRacTuningThis group is used to configure various iDRAC or CMC configuration properties, such as valid ports and security port restrictions.Use this

Strona 84

cfgRacTuneCtrlEConfigDisableDescriptionTo configure iDRAC from the BIOS POST option-ROM, enables or disables the ability of the local user.This object

Strona 85 - Blade Type

• cfgRacTuneIpRanbeMask bit-wise and with cfgRacTuneIpRangeAddrLegal ValuesAn IPv4 address formatted string, for example, 192.168.0.44.Default192.168.

Strona 86

cfgRacTuneIpBlkPenaltyTime (Read or Write)DescriptionDefines the time span in seconds that session requests from an IP address with excessive failures

Strona 87 - Install Date

NOTE: For CMC, the following port numbers are reserved and cannot be used: 21, 68, 69, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, 60106.Legal V

Strona 88

Exampleracadm getconfig -g cfgRacTuning [-m server-<n>] -o<object name> <object value>cfgRacTuneRemoteRacadmEnable=1cfgRacTuneWebser

Strona 89

NOTE: This object property is applicable only to iDRAC.Legal Values• 1 (TRUE — Enables)• 0 (FALSE— Disables)Default1cfgRacTuneLocalConfigDisable (Read

Strona 90

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMCTelnet/SSH/SerialLocal RACADMRemote RACADMTelnet/SSH/SerialLocal RACADMRemote RAC

Strona 91

Default0cfgRacTunePluginType (Read or Write)Description To virtual console from browser, specifies the plug-in type.This object property is applicable

Strona 92

• 1 = Attach• 2 = AutoAttachDefault0cfgVirtualBootOnce (Read or Write)DescriptionEnables or disables the Virtual Media Boot Once feature of iDRAC.If t

Strona 93

For CMC, this group allows you to display and configure a server in the chassis.Use this object with the config or getconfig subcommands.To use this o

Strona 94

cfgServerBIOS (Read Only)Description Displays the server's BIOS revision.This object is applicable only to CMC.Legal ValuesNoneDefaultNonecfgServ

Strona 95

DefaultNonecfgServerPriority (Read/Write)Description Sets the priority level allotted to the server in the chassis for power budgeting purposes.This o

Strona 96

DefaultNonecfgServerDNSIMCName (Read or Write)Description Displays the DNS domain name for the integrated Remote Access Controller (iDRAC).This object

Strona 97

cfgServerBootOnce (Read or Write)Description Enables or disables the server start once feature.For CMC, this object is Write only.Legal Values• 1(True

Strona 98

# cfgServerServiceTag=1S0M0G1cfgServerName=SLOT-01# cfgServerFW=1.40 (Build 12)# cfgServerBIOS=4.0.2# cfgServerBmcMacAddress=00:18:8B:FF:41:43# cfgSer

Strona 99

This object is applicable only to CMC.Legal ValuesAny printable text string of up to 254 characters, with no white space.Default<blank>cfgADEnab

Strona 100

This object is applicable only to iDRAC.Legal ValuesA string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain

Strona 101

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMCTelnet/SSH/SerialLocal RACADMRemote RACADMTelnet/SSH/SerialLocal RACADMRemote RAC

Strona 102

This object is applicable only to CMC.Legal Values• 1 (enabled)• 0 (disabled)Default0cfgADGlobalCatalogDescriptionTo obtain user names, specify the Gl

Strona 103

This object is applicable only to iDRAC.Legal ValuesA string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain

Strona 104

cfgADGcSRVLookupEnable (Read or Write)DescriptionDetermines how the global catalog server is looked up. If using pre‑configured global catalog servers

Strona 105

NOTE: You can specify multiple servers by separating each server with a comma. For example, example.com, sub1.example.comLegal ValuesString.• For iDRA

Strona 106

For CMC: If enabled, the CMC performs DN matching, otherwise the CMC uses the user name provided at login for matching.Legal Values• 1(TRUE) — Use the

Strona 107

cfgLDAPNetworkTimeoutDescription Configures the network timeout in seconds.This object is applicable only to CMC.Legal ValuesPositive integerDefault30

Strona 108

For CMC, this group configures Generic LDAP Role group descriptions and defines the CMC privileges that LDAP-authenticated users are granted.Use this

Strona 109

cfgLocationThis group defines objects that support physical location properties. Use this object with the config or getconfig subcommands.To use this

Strona 110

To use this object property for CMC, you must have the Chassis Configuration Administrator privilege.NOTE: For CMC, you can configure a setting that d

Strona 111

Configure iDRAC 0x00000002Configure Users 0x00000004Clear Logs 0x00000008Execute Server Control Commands 0x00000010Access Virtual Console 0x00000020Ac

Strona 112

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Strona 113

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMCTelnet/SSH/SerialLocal RACADMRemote RACADMTelnet/SSH/SerialLocal RACADMRemote RAC

Strona 114

cfgChassisEPPEnableDescription Enables the Extended Power Performance (EPP).Legal Values• 1 — Enabled• 0 — DisabledDefault0 — DisabledNOTE: For chassi

Strona 115

cfgChassisPowerStatus (Read Only)DescriptionIndicates the power status of the chassis.Legal Values• 1 — (other)• 2 — (unknown)• 3 — (OK)• 4 — (noncrit

Strona 116

Default43221 BTU/hrcfgChassisPowerCapFBTU (Read or Write)DescriptionIndicates the maximum power consumption limit (in BTU/hr) for the entire chassis.

Strona 117

Default0 — (disabled)cfgChassisAllow110VACOperation (Read or Write)Description Enables or disables normal chassis power allocations when any PSU is co

Strona 118

cfgChassisInRedundancyReserve (Read Only)DescriptionIndicates the amount of redundant power (in watts) in reserve that can be utilized in the event if

Strona 119

cfgChassisPowerClearTimestamp (Read Only)DescriptionTime stamp when cfgChassisMinPower and cfgChassisMaxPowerCapacity were reset.Legal ValuesNoneDefau

Strona 120

# cfgSystemEnergyConsumptionClear = ****(Write-Only)cfgChassisServerBasedPowerMgmtMode=0• racadm config -g cfgChassisPower ‑o cfgChassisPowerClear 1Cl

Strona 121

• 4(Administrator)Default4cfgIpmiSolAccumulateInterval (Read or Write)DescriptionSpecifies the typical amount of time that iDRAC waits before transmit

Strona 122

cfgIpmiLanAlertEnable (Read or Write)DescriptionEnables or disables global email alerting. This property overrides all individual email alerting enabl

Strona 123

cfgIpmiPetIPv6AlertEnable (Read or Write)DescriptionEnables or disables the IPv6 alert destination for the trap.Legal Values• 1 (TRUE)• 0 (FALSE)Defau

Strona 124

• For more information about IOM network settings, see the Dell PowerConnect M6220 Switch Important Information document and the Dell PowerConnect 622

Strona 125 - Dell Chassis

cfgIpmiPefEnable (Read or Write)DescriptionEnables or disables a specific platform event filter.Legal Values• 1(TRUE)• 0(FALSE)Default1cfgIpmiPetThis

Strona 126

cfgUserDomainIndex (Read Only)DescriptionRepresents a specific domain.Legal Values1–40DefaultThe index value.cfguserdomainname (Read Only)DescriptionS

Strona 127

This object is applicable only for iDRAC.Legal ValuesNot applicableDefault<blank>cfgServerPowerCapEnable (Read or Write)DescriptionEnables or di

Strona 128

cfgServerPowerConsumptionClear (Write Only)DescriptionClears the current recorded power statistics.This object is applicable only for iDRAC.Legal Valu

Strona 129

cfgServerPowerLastDayAvg (Read Only)DescriptionDisplays the average power value during the last day.This object is applicable only for iDRAC.Legal Val

Strona 130

This object is applicable only for iDRAC.Legal ValuesNot applicableDefaultMaximum power value during the last hour.cfgServerPowerLastHourMaxTime (Read

Strona 131

cfgServerPowerLastDayMaxPower (Read Only)DescriptionDisplays the maximum power value during the last day.This object is applicable only for iDRAC.Lega

Strona 132

• SS = SecondsDefaultTimestamp of the minimum power value during the last week.cfgServerPowerLastWeekMaxPower (Read Only)DescriptionDisplays the maxim

Strona 133

cfgServerActualAmperageConsumption (Read Only)DescriptionDisplays the current power consumption.This object is applicable only for iDRAC.Legal ValuesN

Strona 134

Time in the format: DD MM Date HH:MM:SS YYYYwhere,• DD = Day of the week• MM= Month• Date=Date• YYYY = Year• HH = hour• MM=Minutes• SS = SecondsDefaul

Strona 136

DefaultNonecfgKVMFrontPanelEnableDescriptionEnables or disables front panel access on the iKVM.Legal Values• 1 (enable)• 0 (disable)DefaultNoneExample

Strona 137

Examplesracadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailNameracadm config -g cfgAlerting -o cfgAlertingSourceEmailName [email protected] va

Strona 138

cfgServerPowerSupplyMaxOutputPower (Read Only)DescriptionDisplays the AC output rated power in Watts.Legal ValuesA string of up to 32 characters.Defau

Strona 139

The following sections provide information about the objects in the cfgIPv6LanNetworking group.cfgIPv6Enable (Read or Write)DescriptionEnables or disa

Strona 140

cfgIPv6AutoConfig (Read or Write)DescriptionEnables or disables the IPv6 Auto Configuration option.NOTE: If this value is set to0, the CMC disables au

Strona 141

Default:cfgIPv6Address5 (Read Only)DescriptionThe iDRAC IPv6 fifth address.This object is applicable only for iDRAC.Legal ValuesString representing a

Strona 142

Default:cfgIPv6Address11 (Read Only)DescriptionThe iDRAC IPv6 eleventh address.This object is applicable only for iDRAC.Legal ValuesString representin

Strona 143

NOTE: This property is used only if cfgIPv6AutoConfig is set to 1(true).Legal Values1 (TRUE)0 (FALSE)DefaultFor iDRAC:0 For CMC: 1cfgIPv6DNSServer1 (R

Strona 144

cfgIpv6StaticLanNetworkingThis group is used to configure the IPv6 Static over LAN networking capabilities. This group is applicable only for iDRAC.cf

Strona 145 - Object Descriptions

NOTE: If this object is modified, then the object cfgIPv6Autoconfig is also modified.cfgIPv6StaticDNSServersFromDHCP6 (Read or Write)DescriptionSpecif

Strona 146

2RACADM Subcommand DetailsThis section provides detailed description of the RACADM subcommands including the syntax and valid entries.Guidelines to Qu

Strona 147

cfgNicCurrentGatewayDisplays the static gateway for the CMC IP address.DescriptionDisplays the static gateway for the CMC IP address.Legal ValuesDefau

Strona 148

cfgDNSCurrentServer2DescriptionDisplays the IP address for DNS server 2.Legal ValuesDefaultcfgDNSCurrentDomainNameDescriptionDisplays the DNS domain n

Strona 149

cfgCurrentIPv6AutoConfigWasUsedDescriptionIndicates whether auto configuration is used to obtain IPv6 settings, including stateless IPv6 addresses and

Strona 150

cfgCurrentIPv6DNSServer2DescriptionDisplays the IPv6 address for DNS server 2.Legal ValuesNoneDefaultNoneExampleracadm getconfig -g cfgCurrentIPv6LanN

Strona 151

cfgIpmiSerialChanPrivLimit (Read or Write)DescriptionSpecifies the maximum privilege level allowed on the IPMI serial channel.Legal Values• 2 (User)•

Strona 152

Default1cfgIpmiSerialHandshakeControl (Read or Write)DescriptionEnables or disables the IPMI terminal mode handshake control.Legal Values• 0(FALSE)• 1

Strona 153

cfgSmartCardLogonEnable (Read or Write)DescriptionTo iDRAC using a smart card, enable or disable with Remote RACADM support for access.NOTE: Enabling

Strona 154

• 1 = Auto Negotiation is EnabledDefault1Exampleracadm getconfig -g cfgNetTuningcfgNetTuningNicSpeed=100cfgNetTuningNicFullDuplex=1cfgNetTuningNicMtu=

Strona 155

cfgSensorRedundancyIndex (Read Only)DescriptionSpecifies index for the sensor redundancy group being read. Only power supply redundancy is supported.L

Strona 156

cfgVFlashSDThis group is used to configure the properties for the Virtual Flash SD card. This group is applicable only for iDRAC.NOTE: If the vFlash c

Strona 157

For using single quotation marks:• No character escaping is necessary.• A single quotation mark is not used even with a back slash escaped.NOTE: An em

Strona 158

cfgVFlashSDAvailableSize (Read Only)DescriptionDisplays the available memory (in MB) on the vFlash SD card that can be used to create new partitions.L

Strona 159

cfgVFlashPartitionSize (Read Only)Description Displays the size of the partition.Legal Values 1 MB to 4 GBDefaultNonecfgVFlashPartitionEmulationType (

Strona 160

cfgVFlashPartitionAttachState (Read or Write)DescriptionView or modify the partition to attached or detached.NOTE: Detaching the vFlashPartition by se

Strona 161

cfgRacSecCsrOrganizationName (Read or Write)DescriptionSpecifies the CSR Organization Name (O).Legal ValuesA string of up to 254 characters.Default<

Strona 162

cfgRacSecOrganizationUnit=cfgRacSecLocalityName=cfgRacSecStateName=cfgRacSecCountryCode=cfgRacSecEmailAddr=cfgRacSecCsrKeySize (Read or Write)Descript

Strona 163

4Database Objects With Get and Set CommandsThis chapter provides the database groups and objects that must be used with the get or set subcommands. Th

Strona 164

System.ChassisInfo.Name (Read)Description Provides the name of the chassis. For example: CMC-nobel01.Legal Values String of up to 62 ASCII charactersD

Strona 165

System.LCD.CurrentDisplay (Read Only)DescriptionThe string currently displayed on the LCD.Legal ValuesNoneWrite PrivilegeConfigure iDRACLicense Requir

Strona 166

System.Location.DeviceSize (Read Only)DescriptionIndicates server chassis size.Legal ValuesValues: 1–255Default ValueDepends on the server form factor

Strona 167

System.Location.Chassis.Name (Read Only)DescriptionIndicates the chassis name.Legal ValuesString of up to 128 ASCII charactersWrite PrivilegeConfigure

Strona 168

getkvminfo -- display the KVM module information getled -- display the LED settings on a module getmacaddress -- get MAC/WWN addresse

Strona 169

Default ValueAverage power value during the last day.Write PrivilegeConfigure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneSy

Strona 170

Write PrivilegeConfigure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneSystem.Power.Cap.ActivePolicy.Watts (Read Only)Descript

Strona 171

System.Power.Cap.MaxThreshold (Read Only)DescriptionBecause it is based on the current component inventory, it has maximum server power capacity.Legal

Strona 172

• A/C Input Redundant — In this mode, the system is functional even if one PSU input circuit stops functioning, provided the PSUs are connected to dif

Strona 173

System.Power.EnergyConsumption.Clear (Read or Write)DescriptionClears the cumulative power consumption timestamps.Legal Values1Write PrivilegeConfigur

Strona 174

• 5 — PSU1 and PSU3• 10 — PSU2 and PSU4Write Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.M

Strona 175

System.Power.Max.LastDay (Read Only)DescriptionDisplays the maximum power value during the last day.Legal ValuesValues: 1–65535Default ValueMaximum po

Strona 176

Dependency NoneSystem.Power.Max.LastWeek (Read Only)DescriptionDisplays the maximum power value during the last week.Legal ValuesValues: 1–65535Defaul

Strona 177

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneSystem.Power.Max.PowerClear (Read Only)DescriptionClears the Maximum Power Consumptio

Strona 178

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.Min.LastHour.Timestamp (Read Only)Description Indicates the timestamp o

Strona 179

-4 : show CMC IPv4 information-6 : show CMC IPv6 informationhelp and help <subcommand>DescriptionLists all the subcommands available for use wit

Strona 180

• 1 — EnabledDefault Value• 0 — For platforms that do not support PCIe cards.• 500 W — For platforms that support PCIe cards.Write PrivilegeConfigure

Strona 181

Default Value0 — not applicableSystem.Power.RedundantState (Read Only)DescriptionRetrieves the redundancy state for the chassis.Legal Values• 0 — None

Strona 182

System.Power.Supply.[i].MaxOutputPower (Read Only)DescriptionDisplays the DC output rated power in Watts.Legal ValuesInteger > 0Default 0System.Pow

Strona 183

System.ServerOS.HostName (Read or Write)DescriptionDisplays the host name of the managed server.Legal Values String of up to 256 ASCII charactersWrite

Strona 184

• 255 — NoneDefault value 255 — NoneLicense RequirediDRAC7 ExpressDependency NoneSystem.ThermalSettings.BaseAlgorithm (Read or Write)Description Spec

Strona 185

• 1 — EnabledDefault Value 0 — DisabledWrite Privilege Server ControlLicense RequirediDRAC7 EnterpriseDependency NoneLifecycleController.LCAttributes.

Strona 186

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneLifecycleController.LCAttributes.LifecycleControllerState (Read or Write)Description

Strona 187

iDRAC.ActiveDirectoryTo manage the configuration of the iDRAC Active Directory features, use the objects in this group.iDRAC.ActiveDirectory.AuthTimeo

Strona 188

iDRAC.ActiveDirectory.DCLookupDomainName (Read or Write)Description The configured search domain is used when DCLookupByUserDomain is disabled.Legal V

Strona 189

Write Privilege Configure iDRACLicense RequirediDRAC7 EnterpriseDependencyNoneiDRAC.ActiveDirectory.DomainController3 (Read or Write)Description FQDN

Strona 190

IP Address HW Type Flags HW Address Mask Device192.168.1.1 0x1 0x2 00:00:0C:07:AC:0F* eth0autoupdateschedulerDescription You can automatically update

Strona 191

• IPv6.DNS2iDRAC.ActiveDirectory.GCRootDomain (Read or Write)DescriptionThe names of the Active Directory root domain used for DNS look up.Legal Value

Strona 192

iDRAC.ActiveDirectory.RacDomain (Read or Write)DescriptionActive Directory Domain in which iDRAC resides.Legal Values String of up to 254 ASCII charac

Strona 193

License RequirediDRAC7 EnterpriseDependencyCannot be enabled unless SmartCard Logon Enable is disabled.iDRAC.ADGroupTo manage the configuration of AD

Strona 194

iDRAC.AutoOSLock.AutoOSLockState (Read or Write)Description Enable or Disable OS Auto lock feature.Legal Values • 0 — Disabled• 1 — EnabledDefault Val

Strona 195

Default Value 0 — DisabledWrite Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.InfoTo manage informa

Strona 196

iDRAC.Info.Product (Read Only)Description String identifying the Product.Legal ValuesString of up to 63 ASCII charactersWrite Privilege Configure iDRA

Strona 197

Write Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.IPBlockingTo configure IP address blocking fe

Strona 198

iDRAC.IPBlocking.PenaltyTime (Read or Write)DescriptionDefines the time span in seconds that session requests from an IP address with excessive failur

Strona 199

Write PrivilegeConfigure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPMILanTo configure IPMI over LAN of the system,

Strona 200

DependencyNoneiDRAC.IPMILan.EncryptionKey (Read or Write)Description Enables or disables the IPMI over LAN interface.Legal ValuesString of up to 18 AS

Strona 201

• -pp — Specifies the FTP proxy password.• -po — Specifies the FTP proxy port.• -pt — Specifies the FTP proxy type.• -time — Specifies the time to sch

Strona 202

License Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPMISerial.ChanPrivLimit (Read or Write)Description Specifies the maximum priv

Strona 203

iDRAC.IPMISerial.EchoControl (Read or Write)DescriptionEnables or disables echo control on the IPMI serial interface.Legal Values • 0 — Disabled• 1 —

Strona 204

• 2 — NullDefault Value 2 — NullWrite PrivilegeConfigure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPMISerial.LineE

Strona 205

iDRAC.IPMISOL.AccumulateInterval (Read or Write)Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL ch

Strona 206

• 4—AdministratorDefault Value 4—AdministratorWrite Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.I

Strona 207 - 1-based 5ms

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyCannot be enabled unless IPv4.Enable is enabled.iDRAC.IPv4.DNS1 (Read or Write)Descriptio

Strona 208

iDRAC.IPv4.Enable (Read or Write)DescriptionEnables or disables the iDRAC IPv4 stack.Legal Values• 0 — Disabled• 1 — EnabledDefault Value1 — EnabledWr

Strona 209

iDRAC.IPv4Static.Address (Read or Write)DescriptioniDRAC static IPv4 address. This address can be configured even when DHCP is enabled.Legal ValuesVal

Strona 210

DependencyNoneiDRAC.IPv4Static.Netmask (Read or Write)DescriptioniDRAC static IPv4 subnet mask. This address can be configured even when DHCP is enabl

Strona 211

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPv6.Address 4 (Read Only)Description iDRAC IPv6 fourth address.Legal Values Va

Strona 212

time = 14:30dayofmonth =1repeat = 5applyreboot = 1idracuser = racuser– To clear and display AutoUpdateScheduler parameter:racadm autoupd

Strona 213

iDRAC.IPv6.Address 8 (Read Only)Description iDRAC IPv6 eighth address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLicense RequirediD

Strona 214

iDRAC.IPv6.Address12 (Read Only)Description iDRAC IPv6 twelfth address.Legal ValuesValid IPv6 AddressWrite Privilege Configure iDRACLicense Required i

Strona 215

iDRAC.IPv6.AutoConfig (Read or Write)DescriptionEnables or disables the iDRAC IPv6 auto configuration option.Legal Values• 0 — Disabled• 1 — EnabledDe

Strona 216

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyCannot be Enabled unless IPv6.AutoConfig is enabled.iDRAC.IPv6.Enable (Read or Write)Desc

Strona 217

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPv6StaticTo manage the IPv6 static configuration properties of iDRAC, use the

Strona 218

Default Value0 — DisabledWrite PrivilegeConfigure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.IPv6Static.Gateway (Read

Strona 219

iDRAC.LDAPTo configure properties for LDAP settings, use the objects in this group.iDRAC.LDAP.BaseDN (Read or Write)DescriptionThe Domain Name of the

Strona 220

License RequirediDRAC7 EnterpriseDependencyNoneiDRAC.LDAP.Enable (Read or Write)DescriptionTurns LDAP service on or off.Legal Values• 0 — Disabled• 1

Strona 221

Write PrivilegeConfigure iDRACLicense RequirediDRAC7 EnterpriseDependencyNoneiDRAC.LDAP.SearchFilter (Read or Write)DescriptionA valid LDAP search fil

Strona 222

iDRAC.LDAPRoleGroup.DN (Read or Write)DescriptionThe Domain Name of this group.Legal ValuesString of up to 1024 ASCII charactersWrite PrivilegeConfigu

Strona 223

Contents1 Introduction...

Strona 224

chassisactionDescription Executes a power action on the chassis, iKVM or a server.This subcommand is applicable only for CMC.To use this subcommand, y

Strona 225

• 1 — EnabledDefault Value0 — DisabledWrite PrivilegeConfigure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.LoggingiDRA

Strona 226

NOTE: Always configures the DHCP.Default Values 0 — DisabledWrite Privilege Configure iDRACLicense RequirediDRAC7 EnterpriseDependency NoneiDRAC.NIC.

Strona 227

License RequirediDRAC7 Express (for Blades) or iDRAC7 EnterpriseDependencyNoneiDRAC.NIC.DNSDomainFromDHCP (Read or Write)DescriptionSpecifies that the

Strona 228

iDRAC.NIC.DNSRacName (Read or Write)Description The iDRAC name.Legal ValuesString of up to 63 ASCII charactersWrite Privilege Configure iDRACLicense R

Strona 229

Write Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.NIC.Failover (Read or Write)DescriptionEnables

Strona 230

iDRAC.NIC.Selection (Read or Write)Description Specifies the current mode of operation for the iDRAC network interface controller.Legal Values • 1 — D

Strona 231

iDRAC.NIC.VLanEnable (Read Only)Description Enables or disables the VLAN capabilities of the iDRAC.NOTE: This object is applicable only to iDRAC on Ra

Strona 232

iDRAC.NICStatic.DNSDomainFromDHCP (Read or Write)Description Specifies that the iDRAC DNS domain name must be assigned from the network DHCP server.Le

Strona 233

DependencyNoneiDRAC.NTPConfigGroup.NTP3 (Read or Write)DescriptionConfigure NTP Server 3 Address.Legal ValuesString of up to 254 ASCII characters.Writ

Strona 234

iDRAC.OS-BMC.AdminState (Read or Write)Description On iDRAC pass through, enable or disable administrative state of OS.Legal Values • 0 — Disabled• 1

Strona 235

clearpendingDescription Deletes the pending values of all the attributes (objects) in the device (NIC, BIOS, and Storage).This command is applicable o

Strona 236

iDRAC.Racadm.Enable (Read or Write)Description Enables or disables Remote RACADM interface.Legal Values • 0 — Disabled• 1 — EnabledWrite Privilege Con

Strona 237

Write PrivilegeConfigure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.RFSTo configure Remote file share access to iDRA

Strona 238

iDRAC.Security.CsrCommonName (Read or Write)DescriptionSpecifies the CSR Common Name (CN) that must be an IP as given in the certificate.Legal ValuesS

Strona 239

iDRAC.Security.CsrLocalityName (Read or Write)Description Specifies the CSR Locality (L).Legal Values String of up to 254 ASCII charactersWrite Privil

Strona 240

NOTE: This is supported only for rack and tower systems.iDRAC.Serial.BaudRate (Read or Write)Description Sets the Baud rate on the iDRAC serial port.L

Strona 241

iDRAC.Serial.HistorySize (Read or Write)Description Specifies the maximum size of the serial history buffer.Legal Values Integral values from 0 to 819

Strona 242

iDRAC.SerialRedirection.Enable (Read or Write)DescriptionEnables or disables the console for COM2 port redirection.Legal Values• 0 — Disabled• 1 — Ena

Strona 243

iDRAC.serverboot.FirstBootDeviceDescription Configures the first boot device.Legal Values• Normal• PXE• HDD (Hard Disk Drive)• CD-DVD (Local CD/DVD)•

Strona 244

• 1 — EnabledDefault Value 1 — EnabledWrite Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.Service

Strona 245 - System.ChassisInfo

iDRAC.ServiceModule.WatchdogRecoveryAction (Read and Write)Description Configures recovery action on watchdog alert.Legal Values• 0 — None• 1 — Reboot

Strona 246 - System.LCD

clrraclogDescription Deletes the CMC log.This subcommand is applicable only for CMC.Synopsisracadm clrraclogInputracadm clrraclogclrselDescription Rem

Strona 247 - System.Location

iDRAC.SmartCard.SmartCardCRLEnable (Read or Write)Description Enables or disables the Certificate Revocation List (CRL).Legal Values • 0 — Disabled• 1

Strona 248

iDRAC.SNMP.AgentEnable (Read or Write)Description Enables or disables the SNMP Agent on the iDRAC.Legal Values • 0 — Disabled• 1 — EnabledDefault Valu

Strona 249 - System.Power

License Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.SNMP.TrapFormat (Read or Write)Description Specifies the SNMP format.Legal Val

Strona 250

License RequiredNoneDependencyNoneiDRAC.SSHThe objects in this group provide configuration parameters for the SSH interface to iDRAC.iDRAC.SSH.Enable

Strona 251

iDRAC.SysLogThe objects in this group provide the properties for configuration of the SMTP server.iDRAC.SysLog.Port (Read or Write)DescriptionRemote s

Strona 252 - System.Power.Redundancypolicy

iDRAC.SysLog.Server1 (Read or Write)Description Name of remote syslog server 1.Legal Values String of up to 63 ACSII charactersWrite Privilege Configu

Strona 253

iDRAC.TelnetThe objects in this group provide configuration parameters for the Telnet interface to iDRAC.iDRAC.Telnet.Enable (Read or Write)Descriptio

Strona 254

iDRAC.Time.Timezone (Read or Write)Description Configure the time zone.Legal Values Valid time zone string of up to 32 ASCII characters For example: U

Strona 255

iDRAC.Update.FwUpdatePath (Read or Write)DescriptionSpecifies TFTP path where iDRAC firmware image resides on TFTP server. Path is relative to TFTP ro

Strona 256

iDRAC.Users.Enable (Read or Write)DescriptionEnables or disables an individual user.Legal Values • 0 — Disabled• 1 — EnabledDefault Value0 — Disabled.

Strona 257

For CMC only:racadm config -g <group> -o <object> <value> [-m <module>]InputNOTE: The -f and -p options are not supported for

Strona 258

DependencyBoth username and password must be configured prior to setting this object.iDRAC.Users.Password (Write Only)DescriptionConfiguring the iDRAC

Strona 259

Default Value0 — DisabledWrite Privilege Configure iDRAC and Configure UserLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.Use

Strona 260

iDRAC.vflashpartitionThe objects in this group manage vFlash SD partitions on iDRAC.This group supports the following objects. Up to 16 partitions are

Strona 261 - System.Power.Supply

iDRAC.vflashpartition.FormatType (Read Only)Description Specifies the file system format type of the vFlash SD partition.Legal Values• FAT16• FAT32• E

Strona 262 - System.ServerOS

iDRAC.vflashsd.AvailableSize (Read Only)Description Displays the available memory (in MB) on the vFlash SD card that is used to create new partitions.

Strona 263 - System.ThermalSettings

• 1 — InitializedDefault value NoneWrite Privilege Login and configure iDRACLicense RequirediDRAC7 EnterpriseDependency vFlash SD card must be enabl

Strona 264

iDRAC.VirtualConsoleThe objects in this group enable you to manage virtual console configuration parameters of iDRAC.iDRAC.VirtualConsole.AccessPrivil

Strona 265

iDRAC.VirtualConsole.LocalVideo (Read or Write)DescriptionEnables or disables the local server video.Legal Values• 0 — Disabled• 1 — EnabledDefault Va

Strona 266

Write Privilege Configure iDRACLicense Required iDRAC7 Express (For Blades) or iDRAC7 EnterpriseDependencyNoneiDRAC.VirtualConsole.Timeout (Read or Wr

Strona 267

License RequirediDRAC7 Express (For Blades) or iDRAC7 EnterpriseDependencyNoneiDRAC.VirtualMedia.FloppyEmulation (Read or Write)Description Enables of

Strona 268

For CMC only:• To configure the single property of a group:racadm config -g cfgSerial -o cfgSerialBaudRate• To modify a user password:racadm config -g

Strona 269

Dependency NoneiDRAC.VNCServer.Password (Read or Write)Description Password for logging into VNC session.Legal Values String of up to 8 charactersDef

Strona 270

Default Value1 — EnabledWrite Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneiDRAC.WebServer.HttpPort (Read

Strona 271

iDRAC.WebServer.LowerEncryptionBitLength (Read or Write)Description Lower Encryption Bit Length.Legal Values• 0 — Disabled (Auto Negotiate)• 1 — Enabl

Strona 272

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.BiosBootSettings.BootSeqRetry (Read or Write)Descri

Strona 273

• EnablediScsi• DisabledWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.EmbNic1N

Strona 274

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.EmbNic3Nic4 (Read or Write)DescriptionEnables or disables the

Strona 275

BIOS.IntegratedDevices.IntegratedNetwork1 (Read or Write)DescriptionEnables or disables the Integrated Network Card 1.Legal Values• Enabled• Disabled

Strona 276

DependencyNoneBIOS.IntegratedDevices.InternalSdCard (Read or Write)DescriptionEnables or disables the internal SD Card port.Legal Values• On• OffWrite

Strona 277

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.InternalUsb2 (Read or Write)DescriptionEnables or disables th

Strona 278

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.SriovGlobalEnable (Read or Write)DescriptionEnables or disabl

Strona 279

For more information about clearing the coredump, see the coredumpdelete subcommand.Synopsisracadm coredumpInputNoneOutputNoneExample• racadm coredump

Strona 280

BIOS.MemSettings.MemOpMode (Read Only)DescriptionCurrent memory operating mode.Legal Values• OptimizerMode• SpareMode• MirrorMode• AdvEccMode• SpareWi

Strona 281

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.MemSettings.NodeInterleave (Read or Write)DescriptionIf the system is configured

Strona 282

BIOS.MemSettings.RedundantMemInUse (Read Only)DescriptionDisplay the current redundant memory setting in BIOS.Legal Values• NotInUse• InUseWrite Privi

Strona 283

BIOS.MemSettings.SysMemSpeed (Read Only)DescriptionIndicates the current clock frequency of the main memory.Legal ValuesNoneWrite PrivilegeServer Cont

Strona 284

BIOS.MiscSettings.AssetTag (Read or Write)DescriptionDisplays the current asset tag and the asset tag can be modified.Legal ValuesNoneWrite PrivilegeS

Strona 285

BIOS.MiscSettings.ReportKbdErr (Read or Write)DescriptionEnables or disables the keyboard-related error messages to be reported at system startup.Lega

Strona 286

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency Read Only if OneTimeBootMode is not set to OneTimeBootSeq.B

Strona 287

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.ProcSettings.DataReuse (Read or Write)DescriptionEn

Strona 288

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.LogicalProc (Read or Write)Descriptio

Strona 289

BIOS.ProcSettings.Proc1L3Cache (Read Only)DescriptionAmount of memory in the corresponding processor cache.Legal ValuesNoneWrite PrivilegeServer Contr

Strona 290

where <prefixlen> must be a number between 0 and 128.racadm deploy-m server -<n> -u root -p <password> -d [-6]racadm deploy -m swi

Strona 291

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.Proc2L3Cache (Read Only)DescriptionAm

Strona 292

BIOS.ProcSettings.Proc3L2Cache (Read Only)DescriptionAmount of memory in the corresponding processor cache.Legal ValuesNoneWrite PrivilegeServer Contr

Strona 293

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.Proc4L2Cache (Read Only)DescriptionAmount of memory in the corresp

Strona 294

BIOS.ProcSettings.ProcAdjCacheLine (Read or Write)DescriptionEnables or disables the system optimization for applications that require high utilizatio

Strona 295

BIOS.ProcSettings.ProcCoreSpeed (Read Only)DescriptionClock speed of the processor.Legal ValuesNoneWrite PrivilegeServer ControlLicense RequirediDRAC7

Strona 296

BIOS.ProcSettings.ProcHtAssist (Read or Write)DescriptionWhen enabled it provides filtering of broadcast probes to improve HyperTransport I/O Link ban

Strona 297

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.ProcSettings.ProcVirtualization (Read or Write)DescriptionWhen enabled, the addi

Strona 298

BIOS.ProcSettings.RtidSetting (Read or Write)DescriptionAllocates more RTIDs to the remote socket increasing cache performance between the sockets.Leg

Strona 299

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.eSataPort1DriveType (Read Only)Descri

Strona 300

BIOS.SataSettings.SataPortADriveType (Read Only)DescriptionIndicates type of device attached to this SATA port.Legal ValuesNoneWrite PrivilegeServer C

Strona 301

Example• Set root password, configure static IPV4 address, set first boot device to HDD, and enable boot once for server-1.racadm deploy -m server-1 -

Strona 302

BIOS.SataSettings.SataPortBDriveType (Read Only)DescriptionIndicates type of device attached to this SATA port.Legal ValuesNoneWrite PrivilegeServer C

Strona 303

BIOS.SataSettings.SataPortCDriveType (Read Only)DescriptionIndicates type of device attached to this SATA port.Legal ValuesNoneWrite PrivilegeServer C

Strona 304

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SataSettings.SataPortDDriveType (Read Only)Descript

Strona 305

BIOS.SataSettings.SataPortEDriveType (Read Only)DescriptionIndicates type of device attached to this SATA port.Legal ValuesNoneWrite PrivilegeServer C

Strona 306

DependencyNoneBIOS.SataSettings.SataPortFModel (Read Only)DescriptionDisplays the drive model of the selected device.Legal ValuesNoneWrite PrivilegeSe

Strona 307

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SataSettings.SataPortH (Read or Write)DescriptionSe

Strona 308

BIOS.SerialCommSettingsTo manage the serial port settings, use the objects in the group.BIOS.SerialCommSettings.ConTermType (Read or Write)Description

Strona 309

BIOS.SerialCommSettings.RedirAfterBoot (Read or Write)DescriptionEnables or disables the BIOS console redirection when the operating system is loaded.

Strona 310

BIOS.SlotDisablement.Slot1 (Read or Write)DescriptionControl the configuration of the card installed in slot1.Legal Values• Enabled• Disabled• BootDri

Strona 311

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SlotDisablement.Slot5 (Read or Write)DescriptionCon

Strona 312

• -p <password> — Specifies the password of the remote share to import the file.• -r <reboot type> — Specifies the reboot type. The type c

Strona 313

BIOS.SysInformationTo view information about system configuration, use the objects in this group.BIOS.SysInformation.SysMfrContactInfo (Read Only)Desc

Strona 314

BIOS.SysInformation.SystemModelName (Read Only)DescriptionProvides the product name of the system.Legal ValuesNoneWrite PrivilegeServer ControlLicense

Strona 315

• MaxReliabilityWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyRead Only if SysProfileSettings.SysProfile i

Strona 316

BIOS.SysProfileSettings.MemVolt (Read/Write)DescriptionSets the DIMM voltage selection.Legal Values• AutoVolt• Volt135V• Volt15VLicense RequirediDRAC7

Strona 317

BIOS.SysProfileSettings.ProcCStates (Read or Write)DescriptionEnables or disables the processor C-States.Legal Values• Enabled• DisabledWrite Privileg

Strona 318

• Custom• DenseCfgOptimizedWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SysSecurityTo manage the

Strona 319

Write PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneBIOS.SysSecurity.Aesni (Read or Write)DescriptionDisplay

Strona 320

• SysSecurity.TpmSecurity is not set to OnPbmBIOS.SysSecurity.NmiButton (Read or Write)DescriptionEnables or disables the NMI button on the front pane

Strona 321

• Only lower case alphabets are accepted.• Special characters accepted are +, ",,, — , ., /, ;, [, \, ], `.To enable password modification, J_EN_

Strona 322

BIOS.SysSecurity.TcmClear (Read or Write)DescriptionWarns that clearing the TPM causes loss of all keys in the TPM. It may affect starting the operati

Strona 323

• Updates• Audit• Config• WorknotesValid Severity values are:• Critical• Warning• InfoValid examples of alert descriptors are:• idrac.alert.all• idrac

Strona 324

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyRead Only if SysSecurity.TpmSecurity is set to Off.BIOS.SysSecurity.TpmSecurity (Read or

Strona 325

• UnavailableWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.DCBSettings.EnhancedTransmissionSelecti

Strona 326

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.DeviceLevelConfig.FlowControlSetting (Read or Write)DescriptionConfigure type of

Strona 327

NIC.FCOECapabilities.MaxFrameSize (Read Only)DescriptionIndicates the maximum frame size for each FCoE frame.Legal ValuesNoneWrite PrivilegeServer Con

Strona 328

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.FCOECapabilities.MaxNumberOfFCTargets (Read Only)DescriptionIndicates the maximum

Strona 329

Default ValueDisabledWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.FCoEConfiguration.FirstFCoEBoot

Strona 330

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.FCoEGenParamsThe following section provides information about the objects in the

Strona 331

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.FCoEGenParams.FCoELnkUpDelayTime (Read or Write)DescriptionSpecifies the time FCo

Strona 332

NIC.FrmwImgMenu.ControllerBIOSVersion (Read Only)DescriptionIndicates the controller BIOS version information.Legal ValuesString of up to 8 ASCII char

Strona 333

NIC.GlobalBandwidthAllocation.MinBandwidth (Read or Write)DescriptionSet the minimum percentage of port TX bandwidth allocated to partition.Legal Valu

Strona 334

feature...

Strona 335

• Configure using severity as a parameter. For example, all informational events in storage category are assigned power off as action, and email and s

Strona 336

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNot Available if VndrConfigGroup.iSCSIBootSupport is Unavailable.NIC.IscsiFirstTgtParams.

Strona 337

NIC.IscsiGenParamsThe following section provides information about the objects in the NIC.IscsiGenParams group.NIC.IscsiGenParams.ChapAuthEnable (Read

Strona 338

NIC.IscsiGenParams.FirstHddTarget (Read or Write)DescriptionEnables or disables to check if the iSCSI target appears as the first hard disk drive (HDD

Strona 339

NIC.IscsiGenParams.IscsiViaDHCP (Read or Write)DescriptionEnables the acquisition of iSCSI target parameters from DHCP.Legal Values• Enabled• Disabled

Strona 340

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNot Available if IscsiGenParams.IpVer is set to 'IPv6' and VndrConfigGroup.iSCS

Strona 341

NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Password)DescriptionSet the iSCSI initiator Challenge-Handshake Authentication Protocol (CHAP) secret

Strona 342 - BIOS.BiosBootSettings

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNot available if VndrConfigGroup.iSCSIBootSupport is unavailable.NIC.IscsiInitiatorParams

Strona 343 - BIOS.IntegratedDevices

DependencyNot available if VndrConfigGroup.iSCSIBootSupport is unavailable.NIC.IscsiSecondaryDeviceParams.UseIndTgtName (Read or Write)DescriptionSpec

Strona 344

NIC.IscsiSecondTgtParams.SecondTgtBootLun (Read or Write)DescriptionSpecifies the second iSCSI storage target boot Logical Unit Number (LUN).Legal Val

Strona 345

NOTE: The legal value range may be smaller than the maximum size of 223, based on the vendor configuration of the NIC cards.Write PrivilegeServer Cont

Strona 346

NOTE: To deactivate FlexAddress features, the chassis must be turned off.Synopsisracadm feature -sracadm feature -d -c <featurename>racadm featu

Strona 347

• 100 Mbps Half• 100 Mbps FullWrite PrivilegeServer ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.NICConfig.VLanId (Read

Strona 348

NIC.NICConfig.WakeOnLanLnkSpeed (Read or Write)DescriptionSelect the port speed used for Wake on LAN mode.Legal Values• AutoNeg• 10 Mbps Half• 10 Mbps

Strona 349 - BIOS.MemSettings

NIC.NICPartitioningConfig.NumberPCIEFunctionsSupported (Read Only)DescriptionIndicates the number of physical PCIe functions supported on this port.Le

Strona 350

NIC.VndrConfigGroup.EnergyEfficientEthernet (Read Only)DescriptionIndicates whether Energy Efficient Ethernet capability is supported.Legal ValuesNone

Strona 351

NIC.VndrConfigGroup.FCoEOffloadSupport (Read Only)DescriptionIndicates whether FCoE Offload capability is supported.Legal ValuesNoneWrite PrivilegeSer

Strona 352

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.VndrConfigGroup.ISCSIMacAddr (Read Only)DescriptionIndicates the permanent MAC ad

Strona 353 - BIOS.MiscSettings

NIC.VndrConfigGroup.MacAddr (Read Only)DescriptionIndicates the permanent MAC address assigned during manufacturing.Legal ValuesString of up to 17 cha

Strona 354

NIC.VndrConfigGroup.OnChipThermalSensor (Read Only)DescriptionIndicates whether an on-chip thermal sensor is available.Legal ValuesNoneWrite Privilege

Strona 355 - BIOS.OneTimeBoot

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneNIC.VndrConfigGroup.RXFlowControl (Read Only)DescriptionIndicates whether Receive (RX

Strona 356 - BIOS.ProcSettings

NIC.VndrConfigGroup.TXFlowControl (Read Only)DescriptionIndicates whether Transmit (TX) Flow Control capability is supported.Legal ValuesNoneWrite Pri

Strona 357

Output• No feature card inserted — Action: To verify that the SD card was properly inserted, check the CMC. In a redundant CMC configuration, make sur

Strona 358

NIC.VndrConfigGroup.VirtualLinkControl (Read or Write)DescriptionIndicates whether Virtual Link Control capability is supported.Legal ValuesNoneWrite

Strona 359

License RequirediDRAC7 Express or iDRAC7 EnterpriseDependencyNoneStorage.ControllerThe objects in this group manage storage controller attributes.The

Strona 360

Dependency NoneStorage.Controller.CheckConsistencyRate (Read or Write)Description The Check Consistency rate is the percentage of the system's r

Strona 361

Storage.Controller.EnhancedAutoImportForeignConfig (Read or Write)Description This property indicates the Enhanced Auto Import of Foreign Configuratio

Strona 362

• DisabledDefault valueWrite Privilege Server ControlLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneStorage.Controller.RebuildRate

Strona 363

Dependency NoneStorage.Controller.SupportEnhancedAutoForeignImport (Read Only)Description This is readonly attribute. This property indicates if this

Strona 364

The following section provides information about the objects in this group.Storage.PhysicalDisk.BlockSizeInBytes (Read Only)Description This is readon

Strona 365

• CapableDefault valueWrite Privilege Configure iDRACLicense RequirediDRAC7 Express or iDRAC7 EnterpriseDependency NoneStorage.VirtualDiskThe objects

Strona 366

Storage.VirtualDisk.ReadPolicy (Read or Write)Description The read policies indicate whether or not the controller must read sequential sectors of the

Strona 367 - BIOS.SataSettings

only be a single update operation in progress at any time. In addition, the fwupdate subcommand may only update one or more devices of a single kind a

Strona 368

Input• —u — For iDRAC: The update option performs a checksum of the firmware update file and starts the actual update process. This option may be used

Strona 369

NOTE: iDRAC7 targets are not supported from CMC. To update the iDRAC7 targets, use the CMC GUI.CMC version 3.00 accepts IPv4, IPv6 or fully qualified

Strona 370

To block the firmware downgrade on 3000W AC power supply configuration.racadm fwupdate –s Ready for firmware update racadm fwupdate –g –u –a 10.210.13

Strona 371

For the --clone and --replace options, check the Job ID by running the racadm jobqueue view command. For more information, see jobqueue.Synopsisracadm

Strona 372

NOTE: For --clone and --replace options, only .xml file template is received. These options --clone and --replace cannot be used in the same command.E

Strona 373

• cmc-n — where n=1, 2• fan-n — where n=1–9• ps-n — where n=1–6• chassis• kvm• lcdNOTE: A few of the informational messages are applicable for more th

Strona 374

ping6...

Strona 375

• To display entire information log.racadm getactiveerrors -s infoModule ID = server-1Severity = CriticalMessage = A fabric mismatch deteceted for mez

Strona 376 - BIOS.SerialCommSettings

To run this subcommand, you must have the CMC Login User privilege.Synopsisracadm getassettag [-m <module>]Input -m <module> — Specifies t

Strona 377 - BIOS.SlotDisablement

maximum number of indexes a particular group supports. If -i <index> is not specified, then a value of 1 is assumed for groups, which are tables

Strona 378

getdcinfoDescription Displays general I/O module and daughter card configuration information. Only the CMC controls daughter cards.This subcommand is

Strona 379

server-7 Not Present None N/A None N/Aserver-8 Present FibreChannel 4Invalid None N/Aserver-9 Extension(1) None N/A None N/Aserver-10 Not Present None

Strona 380 - BIOS.SysInformation

getflexaddrDescription Displays enabled/disabled status for the entire chassis. If used with the -i option, the command displays MACs/WWN on a per slo

Strona 381 - BIOS.SysProfileSettings

16 Enabled Not Presentidrac System DisabledDisplay the current flex address setting for slot 1.racadm getflexaddr -i 1 Slot-1 server presence = Presen

Strona 382

Exampleracadm getfanreqinfo[Ambient Temperature Fan Request %]38[Server Module Fan Request Table]<Slot#> <Server Name><Blade Type>

Strona 383

<Slot#> <Server Name><Blade Type> <Power State><Presence> <Fan Request%>1 SLOT-01 PowerEdgeM600ON Present 332 S

Strona 384

Switch-4 N/A None Not Present N/ASwitch-5 N/A None Not Present N/A Switch-6 N/A None Not Present N/ADisplay Enhanced Cooling Mode status.racadm ge

Strona 385 - BIOS.SysSecurity

Displayable Characters...

Strona 386

<Chassis> <IO> <Slot> <Presence><Role> <Unit> <Stack ID>JP4BF2S Switch-1 A1 Present Master N/A N/AJP4BF2S Sw

Strona 387

getledDescription Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).To run this subcommand, you must have th

Strona 388

• -x — Displays the extra MACs (Ethernet or iSCSI) for servers with extra LOM MACs and must be used with -m option.• -a — Displays the Ethernet and iS

Strona 389

Server-5 Present 14:FE:B5:00:F0:B414:FE:B5:00:F0:B514:FE:B5:00:F0:B7Server-6 Not Present Not Installed Not Installed Not InstalledServer-7 Present 14:

Strona 390 - NIC.DCBSettings

Gigabit EthernetPresent 14:FE:B5:00:F0:8314:FE:B5:00:F0:84Server-1-B Gigabit EthernetPresent 14:FE:B5:00:F0:8514:FE:B5:00:F0:86Gigabit EthernetPresent

Strona 391 - NIC.DeviceLevelConfig

iSCSI Present 00:21:9B:FE:39:C100:21:9B:FE:39:C3Server-5-B Gigabit EthernetPresent 14:FE:B5:00:F0:B914:FE:B5:00:F0:BBiSCSI Present 00:10:18:49:EF:1900

Strona 392 - NIC.FCOECapabilities

Server-9-A Gigabit Ethernet Present 14:FE:B5:00:F0:E814:FE:B5:00:F0:E914:FE:B5:00:F0:EAGigabit Ethernet Present 14:FE:B5:00:F0:EB14:FE:B5:00:F0:ECSe

Strona 393

Server-14 Not Installed Not Present Not InstalledNot InstalledNot InstalledServer-15 Not Installed Not Present Not InstalledNot InstalledNot Installed

Strona 394 - NIC.FCoEConfiguration

– fpc-cable• -A — Suppresses headers and labels in the output.Examples• racadm getmodinfo -m switch-1<module> <presence> <pwrState>

Strona 395

Server-6 Present ON OK 1234567Server-7 Present ON OKServer-8 Not Present N/A N/A N/AServer-9 Not Present N/A N/A N/AServer-10 Extension(2) N/A N/A N/A

Strona 396 - NIC.FCoEGenParams

cfgVFlashPartition...

Strona 397 - NIC.FrmwImgMenu

IPv4 settings:NIC Enabled = 1IPv4 Enabled = 1DHCP Enabled = 1IP Address = 10.35.0.64Subnet Mask = 255.255.255.0Gateway = 10

Strona 398 - NIC.GlobalBandwidthAllocation

getpbinfoDescription Displays power budget status information.This subcommand is applicable only for CMC.To run this subcommand, you must have the CMC

Strona 399 - NIC.IscsiFirstTgtParams

2 SLOT-02 OFF 0 W 5 PowerEdgeM8053 SLOT-03 ON 164 W 5 N/A4 SLOT-04 ON 155 W 55 SLOT-05 ON 180 W 56 SLOT-06 ON 180 W 5 PowerEdgeM6007 SLOT-07 ON 170 W

Strona 400

System Potential Power = 68 W (188 BTU/hr)System Input Current Reading = 31.2 A[Real-Time Energy Statistics]System Energy Consumption = 6.4 kWhSystem

Strona 401 - NIC.IscsiGenParams

Example• Display the starting record and the number of records.racadm getraclog -s 10 -c 2• Display a few records and prompt to display another set of

Strona 402

getredundancymodeDescription Displays the redundancy status (Redundant or Non-Redundant) of the CMC.This subcommand is applicable only for CMC.To run

Strona 403

Examples:For CMC:racadm getsensorinfo<senType> <Num> <sensorName><status> <reading> <units> <lc> <uc>F

Strona 404 - NIC.IscsiInitiatorParams

System Board Exhaust TempOk 25 C 3 C 75 CCPU1 Temp Unknown NA NA NASensor Type : FAN<Sensor Name> <Status> <Reading> <lc> <

Strona 405

CPU1 PLL PG Ok Good NA NASystem Board 1.1V PGOk Good NA NACPU1 M23 VDDQ PG Ok Good NA NACPU1 M23 VTT PGOk Good NA NASystem Board FETDRV PGOk Good NA N

Strona 406

DIMM SLOT A2 N/A Absent NA NADIMM SLOT A3 N/A Absent NA NA<Sensor Name> <Status> <State> <lc> <uc>DIMM SLOT A1 Ok Presen

Strona 408

<Sensor Name> <Intrusion> <Status>System Board Intrusion Closed Power ONSensor Type : REDUNDANCY<Sensor Name> <Status> &

Strona 409 - NIC.NICConfig

14 SLOT-14 15 SLOT-15 16 SLOT-16racadm getslotname -i 1Webserver-1getssninfoDescriptionDisplays a list of users that are connect

Strona 410

getsysinfoDescriptionDisplays information related to iDRAC, CMC, managed system, and watchdog configuration.NOTE: The local racadm getsysinfo subcomma

Strona 411 - NIC.NICPartitioningConfig

Enabled = 0Current IP Address 1 = ::Current IP Gateway = ::Autoconfig = 1Link Local IP Address = ::Current IP A

Strona 412 - NIC.VndrConfigGroup

Host Name =OS Name =OS Version =Power Status = ONFresh Air Capable = YesWatchdog Informati

Strona 413

• racadm getversion -l [-m <module>] [-f <filter>]• racadm getversionInput• (none) — Displays the version information for all targets or d

Strona 414

server-2 1.0.3 PowerEdgeM610xserver-4 1.0.0 PowerEdgeM710HDserver-5 1.0.3 PowerEdgeM710server-7 1.0.6 PowerEdgeM620server-9 1.0.5 PowerEdgeM520<Swi

Strona 415

switch-5 Dell PowerConnect M6348 X02switch-6 Dell PowerConnect M6220 A01racadm getversion -l -m server-1<Server> <Component> <Version&g

Strona 416

NIC-PERC S110 Controller3.0.0-0139 2012-10-11RAID-PERC H310 Mini 20.10.1-0084 Reinstall RAID-PERC H310 Mini 20.10.1-0084 Reinstall RAID-PERC H310

Strona 417

NIC FQDD "NIC.Slot.5-1-2" AvailableNIC FQDD "NIC.Slot.5-1-3" AvailableNIC FQDD "NIC.Slot.5-1-4" AvailableTo display the

Strona 418

NIC.IscsiSecondTgtParams...

Strona 419

PCI Sub Vendor ID: 1077PCI Device ID: 2532PCI Sub Device ID: 015c

Strona 420

Fabric Login Retry Count: 0Fabric Login Timeout: 0Port Login Retry Count: 8Port Logi

Strona 421 - Storage.Controller

InputOptions for:racadm inlettemphistory exportSubcommand:• -f — Exports inlet temperature history filename. The maximum length of this parameter is 6

Strona 422

NOTE: To run this subcommand, you must have the Server Profile Export and Import license.Synopsisracadm jobqueue view -i<jobid>where valid optio

Strona 423

Input -f — Specifies the filename of the keytab uploaded. If the file is not specified, the keytab file in the current directory is selected.Output Re

Strona 424

– DE– WSMAN– RACADM– iDRAC_GUI• -c — The category used to filter the records. Provides multiple categories using a "," as the delimiter. The

Strona 425 - Storage.PhysicalDisk

– RemoteUpdate– OsDeployment– USC– Other• —m <Comment> — User comment string for a record that must be inserted in the Lifecycle Controller log.

Strona 426

• Export the complete Lifecycle log in gzip format to a remote CIFS share. racadm lclog export -f log.xml.gz -u admin -p mypass -l //10.94.161.103/sh

Strona 427 - Storage.VirtualDisk

• -o — Overrides the End User License Agreement (EULA) warning and imports, replaces or deletes the license.NOTE: For license operations, <license

Strona 428

• Export license to an NFS share using transaction ID, in this case transaction 27.racadm license export -f License.xml -l 192.168.2.140:/licshare-t 2

Komentarze do niniejszej Instrukcji

Brak uwag