Table 6-12. Host Control Settings
Variable Name:
DellHostControlSettings
NOTE:
An operator can manually cause these actions using SNMP.
Data Type: Integer
Possible Data Values Meaning of Data Value
manualReboot(1) The operator can reboot the host.
manualPowerOFF(2) The operator can power off the host.
manualPowerCycle(4) Power cycle the host.
manualOperatingSystemShutdown(8) The operator can shut down the
operating system on the host.
manualOperatingSystemShutdownThe
nPowerCycle(12)
The operator can shut down the
operating system on the host then
power cycle machine.
Table 6-13. Watchdog Control Capabilities
Variable Name:
DellWatchDogControlCapabilities
NOTE:
When the system determines that the operating system is not responding, it
automatically performs the selected action without operator intervention.
Data Type:
Integer
Possible Data Values Meaning of Data Value
automaticRebootCapable(1) Watchdog controls can be set to
reboot capable host.
automaticPowerCycleCapable(2) Watchdog controls can be set to
power cycleable capable host.
automaticNotificationCapable(4) Watchdog controls can be set to
notify capable host.
automaticWatchDogTimerCapable(8) Watchdog controls can be set to
function automatically.
automaticPowerOffCapable(16) Watchdog controls can be set to
automatically power off host.