Dell PowerEdge 2850 Instrukcja Naprawy

Przeglądaj online lub pobierz Instrukcja Naprawy dla Serwery Dell PowerEdge 2850. Dell PowerEdge 2850 Installation and Troubleshooting Guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide
Introduction
Indicators, Messages, and Codes
Finding Software Solutions
Running System Diagnostics
TroubleshootingYourSystem
Installing System Options
Installing Drives
Getting Help
Jumpers and Connectors
I/O Connectors
Notes, Notices, and Cautions
Abbreviations and Acronyms
For a complete list of abbreviations and acronyms, see the "Glossary" in the User's Guide.
Information in this document is subject to change without notice.
©2004DellInc.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, PowerApp, PowerEdge, PowerConnect, PowerVault, DellNet, Axim, and Latitude are
trademarks of Dell Inc.; Microsoft, MS-DOS, and Windows are registered trademarks of Microsoft Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
June 2004
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Przeglądanie stron 0
1 2 3 4 5 6 ... 75 76

Podsumowanie treści

Strona 1 - Abbreviations and Acronyms

Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide Introduction Indicators, Messages, and Codes Finding Software Solutions Running S

Strona 2 -  Jumpers and Connectors

Network Cable Requirements The NIC supports a UTP Ethernet cable equipped with a standard RJ45-compatible plug. Observe the following cabling restri

Strona 3 - System Board Connectors

Back to Contents Page  Introduction Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide Other Documents You May Need Obtainin

Strona 4

Back to Contents Page  Indicators, Messages, and Codes Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide Indicators on the Opt

Strona 5

Table 2-2. Front-PanelLEDIndicators,Buttons,andConnectors SCSI Hard-Drive Indicator Codes If RAID is activated, two indicators on each of t

Strona 6

Table2-3 lists the drive indicator patterns. Different patterns are displayed as drive events occur in the system. For example, if a hard-drive fai

Strona 7 -  I/O Connectors

Power Indicator Codes The system has indicators on the front panel and the power supplies that signify system power status.  Power-Button Indicator

Strona 8 - Video Connector

Table 2-7. NIC Indicator Codes LCD Status Messages The system's bezel indictor can signify when the system is operating correctly or when th

Strona 9 - Integrated NIC Connectors

range. board (see "Installing Drives"). If the problem persists, see "Troubleshooting Power Supplies" in "Troubleshooting You

Strona 10 - Network Cable Requirements

 Solving Problems Described by LCD Status Messages When a single message appears on the status LCD, locate the code in Table2-8 and perform the sugg

Strona 11 -  Introduction

Table 2-9.SystemMessages  Message  Causes  Corrective Actions Address mark not found Faulty optical/diskette drive subsystem or hard-drive subs

Strona 12

Back to Contents Page  Jumpers and Connectors Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide Jumpers—AGeneralExplanation

Strona 13

I/O parity interrupt at address Faulty or improperly installed expansion card. See "Troubleshooting Expansion Cards" in "Troubleshootin

Strona 14

System Beep Codes If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the pr

Strona 15 - NIC Indicator Codes

If a beep code is emitted, write down the series of beeps and then look it up in Table2-10. If you are unable to resolve the problem by looking up th

Strona 16 - LCD Status Messages

Warning Messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, befo

Strona 17

Back to Contents Page  Finding Software Solutions Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide Before You Begin Troubl

Strona 18 - System Messages

Back to Contents Page  IRQ2 Interrupt controller 1 to enable IRQ8 through IRQ15 IRQ3 Available IRQ4 Serial port 1 (COM1 and COM3) IRQ5 Remote access

Strona 19 - Table 2-9.SystemMessages

Back to Contents Page  Running System Diagnostics Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide Using Server Administrator

Strona 20

 1. Create a set of diagnostics diskettes from the Dell OpenManage Server Assistant CD. See "Using the Dell OpenManage Server Assistant CD"

Strona 21 - System Beep Codes

Back to Contents Page TroubleshootingYourSystem Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide  Safety First—For You a

Strona 22

 Problem l Monitor is not working properly. l Video memory is faulty.  Action  1. Check the system and power connections to the monitor.  2

Strona 23 - Alert Messages

Table A-1. System Board Jumper Settings System Board Connectors See FigureA-3 and TableA-2 for the location and description of system board con

Strona 24 - Before You Begin

If the problem is resolved, replace the faulty mouse. See "Getting Help."  5. Enter the System Setup program and ensure that the mouse cont

Strona 25

 2. Turn off the system and any USB devices.  3. Disconnect the USB devices, and connect the malfunctioning device to the other USB connector.

Strona 26 - From the Utility Partition

In Figure5-1, the covers and bezel are removed to provide an interior view of the system. Figure 5-1. Inside the System The system board holds the

Strona 27 - Error Messages

 1. Fit the tabs on the right end of the bezel into the corresponding slots in the front panel.  2. Rotate the left end of the bezel toward the s

Strona 28 - Checking the Equipment

l Excessive humidity.  Action   1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  2. O

Strona 29 - Troubleshooting the Mouse

 Problem l System message indicates a problem with the battery. l System Setup program loses system configuration information. l System date and

Strona 30

Problem l Systems management software issues a fan-related error message.  Action Ensure that none of the following conditions exist: l Ambient te

Strona 31 - Inside the System

 1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics." 

Strona 32 - Replacing the Bezel

 2. Open or remove the bezel. See "Removing the Bezel."  3. Run the appropriate online diagnostic test. See "Using Server Adminis

Strona 33 - Closing the System

 1. Try using a different CD that you know works properly.  2. Enter the System Setup program and ensure that the drive's IDE or SCSI contro

Strona 34 - Problem

Table A-2. System Board Connectors Expansion-Card Riser-Board Components and PCI Buses FigureA-4 shows the components on the PCI-X expansion-car

Strona 35

 11. Close the system. See "Closing the System."  12. Reconnect the system to the electrical outlet, and turn on the system, including

Strona 36 - Troubleshooting a Fan

If the problem persists, see "Getting Help." Troubleshooting an Integrated RAID Controller  Problem l Error message indicates an integra

Strona 37

 Problem l Error message indicates a RAID controller problem. l RAID controller performs incorrectly or not at all.  Action   1. Run the appro

Strona 38

8. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  9. Open the system. See "Opening the

Strona 39

 11. Close the system. See "Closing the System."  12. Reconnect the system to the electrical outlet, and turn on the system and attache

Strona 40

Back to Contents Page  Installing System Options Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide System Fans Power Suppli

Strona 41

 Replacing a Cooling Fan  1. Ensure that the fan handle is upright and lower the fan into its retention base until the fan is fully seated. Then low

Strona 42

  1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  2. Open the system. See &qu

Strona 43

Expansion Cards The system is available with a PCI-X riser board or an optional PCI-X/PCI Express (PCIe) riser board. The PCI-X riser board provides

Strona 44

4. Disconnect all expansion-card cables.  5. Remove the expansion-card cage. See "Removing the Expansion-Card Cage."  6. Position th

Strona 45 -  Installing System Options

FigureA-5 shows the components on the optional PCI-X/PCIe expansion-card riser board, including the expansion-card slots and buses. Table6-2 lists

Strona 46 - Expansion-Card Cage

a. Open the expansion-card latch. See Figure6-4. b. Grasp the expansion card by its top corners, and carefully remove it from the expansion- car

Strona 47

Table 6-4. Allowable Memory Module Configurations – Single-Ranked and Dual-Ranked Memory Modules  Installing Memory Modules   1. Open the system.

Strona 48 - Expansion Cards

 6. Press down on the memory module with your thumbs while pulling up on the ejectors with your index fingers to lock the memory module into the soc

Strona 49 - Removing an Expansion Card

 3. Press the tab on the end of one of the heat-sink retention levers to disengage the lever, then lift the lever 90 degrees. See Figure6-6. Figu

Strona 50 - System Memory

 9. Unpack the new processor. If any of the pins on the processor appear bent, see "Getting Help."  10. Align the pin-1 corner of the pr

Strona 51 - Installing Memory Modules

 1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  2. Open the system. See "

Strona 52 - Processors

2. Open the system. See "Opening the System" in "Troubleshooting Your System."  3. Remove the two system fans. See "Remov

Strona 53

b. Align the alignment pin on the bottom of the fan tray with the alignment hole on the system board. c. Slide the fan tray straight down. d. P

Strona 54 - System Battery

Back to Contents Page  Installing Drives Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide SCSI Interface Cables SCSI Confi

Strona 55

 4. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  5. Perform a tape backup and ver

Strona 56

 3. Lift up the memory module shroud.  4. Remove the jumper plug from the password jumper. See FigureA-2 to locate the password jumper (labe

Strona 57

l SCSI controller: ¡ Integrated SCSI controller ¡ Optional integrated RAID controller. See "Activating the Integrated RAID Controller."

Strona 58 -  Installing Drives

If the drive has been online, the drive status indicator will blink green two times a second as the drive is powered down. When all indicators are of

Strona 59 - SCSI Hard Drives

4. Replace the bezel. See "Replacing the Bezel" in "Troubleshooting Your System."  5. Reconnect your system and peripherals to

Strona 60 - Removing a SCSI Hard Drive

 12. Gently pull and hold open the RAID battery compartment tab, route the RAID battery cable through the bottom opening, and then lower the RAID b

Strona 61

 1. Unpack the RAID controller card and prepare it for installation. For instructions, see the documentation accompanying the card.  2. Turn off t

Strona 62

 7. Reconfigure the SCSI cable connections to the SCSI backplane as necessary to operate the backplane as a 2/4 split backplane: l If a RAID con

Strona 63

Back to Contents Page  Getting Help Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide Technical Assistance Dell Enterprise

Strona 64

support.jp.dell.com (Japan only) support.euro.dell.com (Europe only) l Electronic Quote Service [email protected] [email protected] (Asian/Pacific c

Strona 65

the system diagnostics.  4. Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diske

Strona 66 -  Getting Help

International Access Code Country Code City Code Anguilla General Support toll-free:800-335-0031 Antigua and Barbuda General Support 1-800-805-5924

Strona 67 - Product Information

Back to Contents Page  I/O Connectors Dell™PowerEdge™2850SystemsInstallationandTroubleshootingGuide Serial Connector PS/2-Compatible Ke

Strona 68 - Dell Contact Numbers

Spare Parts Sales & Extended Service Sales 18664403355 Cayman Islands General Support 1-800-805-7541 Chile (Santiago) Country Code: 56 City Cod

Strona 69

Switchboard 0925331300 France (Paris) (Montpellier) International Access Code: 00 Country Code: 33 City Codes: (1) (4) Website: support.euro.dell.c

Strona 70

Ireland Sales 012044444 U.K. Sales (dial within U.K. only) 08709074000 Fax/SalesFax 012040103 Switchboard 012044444 Italy (Milan) Internationa

Strona 71

Transaction Sales toll-free:0800581 Malaysia (Penang) International Access Code: 00 Country Code: 60 City Code: 4 Technical Support (Dell Precision,

Strona 72

Peru General Support 0800-50-669 Poland (Warsaw) International Access Code: 011 Country Code: 48 City Code: 22 Website: support.euro.dell.com  E-mail

Strona 73

International Access Code: 00 Country Code: 41 City Code: 22 E-mail: [email protected]  E-mail for French-speaking HSB and Corpor

Strona 74

Back to Contents Page  Extended Service and Warranty Sales toll-free:1-800-247-4618 Fax toll-free:1-800-727-8320 Dell Services for the Deaf, Hard-o

Strona 75

Table B-2.SerialConnectorPinAssignments PS/2-Compatible Keyboard and Mouse Connectors The PS/2-compatible keyboard and mouse cables attach t

Strona 76

USB Connectors The system's USB connectors support USB-compliant peripherals such as keyboards, mice, and printers and may also support USB-com