Dell PowerEdge 1850 Instrukcja Naprawy

Przeglądaj online lub pobierz Instrukcja Naprawy dla Serwery Dell PowerEdge 1850. Dell PowerEdge 1850 Installation and Troubleshooting Guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide
Introduction
Indicators, Messages, and Codes
Finding Software Solutions
Running the System Diagnostics
Troubleshooting Your System
Installing System Components
Installing Drives
Getting Help
Jumpers, Switches, and Connectors
I/O Connectors
Notes, Notices, and Cautions
Abbreviations and Acronyms
For a complete list of abbreviations and acronyms, see the Glossary in your User's Guide.
Information in this document is subject to change without notice.
©2004-2009DellInc.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, PowerApp, PowerEdge, PowerConnect, PowerVault, DellNet, Axim, Latitude, and Dell
OpenManage are trademarks of Dell Inc.; Intel and Pentium are registered trademarks of Intel Corporation; Microsoft and Windows are registered trademarks of Microsoft Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
Initial release: 9 Aug 2004
Laste Updated: 17 Jun 2009
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Przeglądanie stron 0
1 2 3 4 5 6 ... 72 73

Podsumowanie treści

Strona 1 - Abbreviations and Acronyms

Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Introduction Indicators, Messages, and Codes Finding Software Solutions Running

Strona 2 - System Board Jumpers

Network Cable Requirements The NIC supports a UTP Ethernet cable equipped with a standard RJ45-compatible plug. Observe the following cabling restr

Strona 3 - System Board Connectors

Back to Contents Page  Introduction Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Other Documents You May Need Your sys

Strona 4 - Riser Board Connectors

Back to Contents Page  Indicators, Messages, and Codes Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Front-Panel Indicato

Strona 5 - SCSI Backplane Connectors

Table 2-2. Front-PanelLEDIndicators,Buttons,andConnectors Back-Panel Features and Indicators Figure2-2 shows the controls, indicators, and

Strona 6

Figure 2-3. NIC Connector Release Latch SCSI Hard-Drive Indicator Codes If RAID is activated, two indicators on each of the hard-drive carriers

Strona 7 -  I/O Connectors

pattern. Table 2-3. Hard-DriveIndicatorPatterns Power Indicator Codes The power button on the front panel controls the power input to the system

Strona 8 - Video Connector

Table 2-6.NICIndicators System Messages System messages appear on the screen during system boot to notify you of a possible problem with the s

Strona 9 - Integrated NIC Connectors

not responding to system requests. Error: Incorrect memory configuration. Ensure memory in slots DIMM1_A and DIMM1_B, DIMM2_A and DIMM2_B, DIMM3_A and

Strona 10 - Network Cable Requirements

System Beep Codes If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the pr

Strona 11 -  Introduction

If a beep code is emitted, write down the series of beeps and then look it up in Table2-8. If you are unable to resolve the problem by looking up the

Strona 12 - System Status Indicators

Back to Contents Page  Jumpers, Switches, and Connectors Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Jumpers—A General

Strona 13

Diagnostics Messages When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record

Strona 14

Back to Contents Page  Finding Software Solutions Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Before You Begin Troub

Strona 15 - NIC Indicator Codes

Back to Contents Page  IRQ0 System timer IRQ1 Keyboard controller IRQ2 Interrupt controller 1 to enable IRQ8 through IRQ15 IRQ3 Available IRQ4 Serial

Strona 16 - System Messages

Back to Contents Page  Running the System Diagnostics Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Using Server Administ

Strona 17

 1. Create a set of diagnostics diskettes from the Dell OpenManage Server Assistant CD. See "Using the Dell OpenManage Server Assistant CD"

Strona 18 - System Beep Codes

l Parameters — If applicable, displays parameters that you can set for the test. Back to Contents Page 

Strona 19 - Warning Messages

Back to Contents Page  Troubleshooting Your System Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Safety First—For You and

Strona 20 - Alert Messages

 2. If the system is connected to a PDU or UPS, turn the PDU or UPS off and then on.  3. If the PDU or UPS is not receiving power, plug it into

Strona 21 - Before You Begin

Problem l System message indicates a problem with the mouse. l Mouse is not functioning properly.  Action  1. Run the appropriate online diagnos

Strona 22

 4. Turn off the system and the serial device, and swap the device with a comparable device.  5. Turn on the system and the serial device. If t

Strona 23 - From the Utility Partition

Table A-1.SystemBoardJumperSettings System Board Connectors See FigureA-3 and TableA-2 for the location and description of the system boar

Strona 24

3. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.  4. Enter the System Setup pro

Strona 25 - Back to Contents Page

  2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals.  3. Remove the system

Strona 26 - Start-Up Routine

Troubleshooting a Wet System  Problem l Liquid spilled on the system. l Excessive humidity.  Action   1. Turn off the system and attached pe

Strona 27 - Checking the Equipment

l Memory modules l Processor(s) l Power supplies l Fans l Drive-carrier connections to the SCSI backplane board  4. Ensure that all cables

Strona 28

If the problem persists, remove the faulty power supply. See "Removing a Power Supply" in "Installing System Components."  4. Ins

Strona 29 - Troubleshooting a NIC

 2. Turn on the system and attached peripherals. If an error message does not appear, go to step 11.  3. Enter the System Setup program and chec

Strona 30 - Opening the System

 4. Open the system. See "Opening the System."  5. Ensure that the diskette drive interface cable is securely connected to the SCSI b

Strona 31 - Closing the System

 5. Open the system. See "Opening the System."  6. Ensure that the optical drive interface cable is securely connected to the optical

Strona 32 - Problem

l Hard drive not recognized by the system.  Action   1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnos

Strona 33

  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

Strona 34

Table A-2.SystemBoardConnectors Riser Board Connectors See FigureA-4, FigureA-5, and FigureA-6 for the location and description of the ris

Strona 35

 2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  3. Open the system. See "Opening t

Strona 36

e. Run the appropriate diagnostic test. If the tests fail, see "Getting Help." Troubleshooting the Microprocessors  Problem l Error

Strona 37

 20. Open the system. See "Opening the System."  21. Reinstall the second processor that you removed in step 10. See "Replacing

Strona 38

Back to Contents Page  Installing System Components Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide System Board Components

Strona 39

System Battery  Replacing the System Battery   1. Enter the System Setup program and record the option settings on the System Setup screens. Se

Strona 40

 1. Open the system. See "Opening the System" in Troubleshooting Your System."  2. Disconnect the fan module's power cable fr

Strona 41

 Replacing a Power Supply  1. Slide the new power supply into the chassis until the power supply is fully seated and the retention latch is engage

Strona 42

 3. Remove the filler bracket on the slot you will be using.  4. Insert the expansion card firmly into the expansion-card connector on the riser

Strona 43 - System Board Components

Removing the Riser Card   1. Open the system. See "Opening the System" in "Troubleshooting Your System."  2. Remove any expa

Strona 44 - System Battery

System Memory The six memory module sockets can accommodate from 256 MB to 16GB of registered ECC PC2-3200 (DDR 2 400) memory. The memory sockets ar

Strona 45 - Power Supplies

Figure A-6. Optional ROMB PCI-Express Riser Card (when available) SCSI Backplane Connectors See FigureA-7 for the location and description of

Strona 46 - Expansion Cards

Table 6-2. Allowable Memory Module Configurations – Single-Ranked and Dual-Ranked Memory Modules  Installing Memory Modules   1. Open the system.

Strona 47 - Riser Card

6. Repeat step 2 through step 5 of this procedure to install the remaining memory modules. See Table6-1 and Table6-2 for sample memory configuration

Strona 48 - Installing the Riser Card

 3. Wait 30 seconds for the heat sink to loosen from the processor.  4. Open the other heat sink retention lever. See Figure6-9.  5. If th

Strona 49 - System Memory

When the processor is positioned correctly, it drops down into the socket with minimal pressure. c. When the processor is fully seated in the socket,

Strona 50 - Installing Memory Modules

c. Press the other end of the card until the remaining two standoffs fit over the card edge.  5. Close the system. See "Closing the System&

Strona 51 - Processor

Back to Contents Page  Installing Drives Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Installing SCSI Hard Drives Ins

Strona 52

 4. Insert the hard drive into the drive bay. See Figure7-1.  5. Close the hard-drive handle to lock the drive in place.  6. Replace the f

Strona 53 - Installing a RAC Card

5. If you are replacing an existing drive, install the new drive in the drive carrier. See"Installing a Diskette or Optical Drive in a Drive Carr

Strona 54

 7. Connect the diskette drive data cable to the diskette drive connector on the SCSI backplane. See Figure7-3.  8. Close the system. See &quo

Strona 55 -  Installing Drives

Connecting an External SCSI Tape Drive This subsection describes how to configure and install an external SCSI tape drive with an optional add-in

Strona 56 - Removing a SCSI Hard Drive

 4. If you removed the riser card insulator in step 3, reinstall it now. See "Installing the Riser Card" in "Installing System Compone

Strona 57

Activating the Optional Integrated RAID Controller This document explains how to activate your system's integrated RAID controller on the optio

Strona 58

 14. Install and configure the RAID software. See the RAID software documentation for more information. Installing a RAID Controller Card See &

Strona 59 - Configuring the Boot Drive

Back to Contents Page  Getting Help Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Technical Assistance Dell Enterprise

Strona 60

support.jp.dell.com (Japan only) support.euro.dell.com (Europe only) l Electronic Quote Service [email protected] [email protected] (Asian/Pacific c

Strona 61 - Connecting the Card

the system diagnostics.  4. Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diske

Strona 62 -  Getting Help

International Access Code Country Code City Code Anguilla General Support toll-free:800-335-0031 Antigua and Barbuda General Support 1-800-805-5924

Strona 63 - Product Information

Spare Parts Sales & Extended Service Sales 18664403355 Cayman Islands General Support 1-800-805-7541 Chile (Santiago) Country Code: 56 City Cod

Strona 64 - Contacting Dell

Switchboard 0925331300 France (Paris) (Montpellier) International Access Code: 00 Country Code: 33 City Codes: (1) (4) Website: support.euro.dell.c

Strona 65

Ireland Sales 012044444 U.K. Sales (dial within U.K. only) 08709074000 Fax/SalesFax 012040103 Switchboard 012044444 Italy (Milan) Internationa

Strona 66

Transaction Sales toll-free:0800581 Malaysia (Penang) International Access Code: 00 Country Code: 60 City Code: 4 Technical Support (Dell Precision,

Strona 67

Back to Contents Page  I/O Connectors Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Serial Connector PS/2-Compatible K

Strona 68

Peru General Support 0800-50-669 Poland (Warsaw) International Access Code: 011 Country Code: 48 City Code: 22 Website: support.euro.dell.com  E-mail

Strona 69

International Access Code: 00 Country Code: 41 City Code: 22 E-mail: [email protected]  E-mail for French-speaking HSB and Corpor

Strona 70

Back to Contents Page  Extended Service and Warranty Sales toll-free:1-800-247-4618 Fax toll-free:1-800-727-8320 Dell Services for the Deaf, Hard-o

Strona 71

Back to Contents Page Dell™PowerEdge™1850SystemsInstallationandTroubleshootingGuide Notes, Notices, and Cautions Abbreviations and Acronym

Strona 72

Figure B-2. Serial Connector Pin Numbers Table B-2.SerialConnectorPinAssignments PS/2-Compatible Keyboard and Mouse Connectors The PS/2-com

Strona 73 - Abbreviations and Acronyms

Table B-4. Video Connector Pin Assignments USB Connectors The system's USB connectors support USB-compliant peripherals such as keyboards, mic

Komentarze do niniejszej Instrukcji

Brak uwag