Dell Computer Drive CMC 3.2 Instrukcja Użytkownika Strona 241

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 292
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 240
iDRAC6 and CMC Property Database Group and Object Descriptions 241
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgServerPowerConsumptionClear (Write Only)
NOTE: This object is applicable only for iDRAC6.
cfgServerPowerCapWatts (Read/Write)
NOTE: This object is applicable only for iDRAC6.
cfgServerPowerCapBtuhr (Read/Write)
NOTE: This object is applicable only for iDRAC6.
cfgServerPowerCapPercent (Read/Write)
NOTE: This object is applicable only for iDRAC6.
Description Resets the cfgServerPeakPowerConsumption (Read/Write)
property to 0 and the cfgServerPeakPowerConsumptionTimestamp
property to the current iDRAC time.
Legal Values 1 (TRUE)
0 (FALSE)
Default None
Description Represents the server power threshold in Watts.
Legal Values A string of up to 32 characters.
Default Server power threshold in Watts.
Description Represents the server power threshold in BTU/hr.
Legal Values A string of up to 32 characters.
Default Server power threshold in BTU/hr.
Description Represents the server power threshold in percentage.
Legal Values A string of up to 32 characters.
Default Server power threshold in percentage.