Configuring Boot From SAN Using iSCSI-Based Dell Storage Arrays
7. Under Initiator Parameters, enter the following information:
IP Address: <host IP Address>
Subnet Mask: <host netmask>
Default Gateway: Not required, if the iSCSI initiator (this host) and the iSCSI target reside on the
same subnet
Primary DNS: Usually not required
Secondary DNS: Usually not required
iSCSI Name: The server will auto-generate an IQN name for this host. If the target is set to
control access based on an IQN name, then this name must be changed to
match the IQN configured on the target (see “Configuring the Dell EqualLogic
Storage System” on page 6 or ”Configuring the PowerVault MD3000i Storage
Array” on page 7).
CHAP ID: (optional)
CHAP Secret: (optional)
Page 15
Przeglądanie stron 16