Dell OpenManage Server Administrator Version 5.5 Podręcznik Użytkownika Strona 107

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 238
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 106
Storage Management Message Reference 107
2103 Temperature
dropped
below the
minimum
failure
threshold
Critical /
Failure /
Error
Cause: The physical disk
enclosure is too cool.
Action: Check if the
thermostat setting is too
low and if the room
temperature is too cool.
Clear Alert
Number:
None.
Related Alert
Number: 2112
LRA Number:
2091
1054
2104 Controller
battery is
reconditioni
ng
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number: 2105.
Related Alert
Number:
None.
LRA Number:
None.
1151
2105 Controller
battery
recondition
is completed
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2105 is a clear
alert for alert
2104.
Related Alert
Number:
None.
LRA Number:
None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Przeglądanie stron 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 237 238

Komentarze do niniejszej Instrukcji