118 Storage Management Message Reference
2122 Redundancy
degraded
Warning /
Non-
critical
Cause: One or more of the
enclosure components has
failed.
For example, a fan or power
supply may have failed.
Although the enclosure is
currently operational, the
failure of additional
components could cause
the enclosure to fail.
Action: Identify and replace
the failed component. To
identify the failed
component, select the
enclosure in the tree view
and click the Health
subtab. Any failed
component will be
identified with a red "X" on
the enclosure’s Health
subtab. Alternatively, you
can select the Storage
object and click the
Health subtab.
Clear Alert
Status: 2124.
Related Alert
Number: 2048
LRA Number:
2090
1305
2122
contd.
The controller status
displayed on the Health
subtab indicates whether
a controller has a failed or
degraded component.
See the enclosure
documentation for
information on replacing
enclosure components and
for other diagnostic
information.
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers