Dell OpenManage Server Administrator Version 6.5 Podręcznik Użytkownika Strona 110

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 250
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 109
110
Storage Management Message Reference
2126 SCSI sense
sector reassign
Warn ing /
Non-critical
Cause:
A sector of the
physical disk is
corrupted and data
cannot be maintained
on this portion of the
disk. This alert is for
informational purposes.
CAUTION:
Any
data residing on the
corrupt portion of the
disk may be lost and you
may need to restore your
data from backup.
Action:
If the physical
disk is part of a non-
redundant virtual disk,
then back up the data
and replace the physical
disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk causes the virtual
disk to fail and may
cause data loss.
If the disk is part of a
redundant virtual disk,
then any data residing
on the corrupt portion
of the disk is reallocated
elsewhere in the
virtual disk.
Clear Alert
Number:
None
Related Alert
Number:
None
LRA Number:
None
903
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Przeglądanie stron 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 249 250

Komentarze do niniejszej Instrukcji

Brak uwag