Dell OpenManage Server Administrator Version 6.5 Podręcznik Użytkownika Strona 209

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 250
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 208
Storage Management Message Reference
209
2384 The Warning
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
Warning /
Non-critical
Cause:
The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action:
Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
1203
2385 The Critical
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
Critical /
Failure / Error
Cause:
The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action:
Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
1204
2386 The drive
could not be
assigned as a
Dedicated Hot
Spare.
Warning /
Non-critical
Cause:
The assignment
of a Dedicated Hot
Spare fails as the disk is
invalid.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Przeglądanie stron 208
1 2 ... 204 205 206 207 208 209 210 211 212 213 214 ... 249 250

Komentarze do niniejszej Instrukcji

Brak uwag