Dell Compellent Series 30 Instrukcja Użytkownika Strona 19

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 70
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 18
13
Configuring a System via the Startup Wizard
2 MB: (Default) Recommended for most application needs.
512 KB: Appropriate for applications with high performance needs or environments
in which Replays are taken frequently under heavy I/O. Selecting this size reduces
the amount of space the System Manager can present to servers.
4 MB: Appropriate for systems that use a large amount of disk space with infrequent
Replays.
5 Prepare for Non-Redundant Storage: Non-redundant storage does not protect data in
the event of a disk failure. Non-redundant storage uses RAID 0. Select Prepare for
Non-Redundant Storage only for data which is backed up in some other way.
6 Click Continue.
7 On the next window, click OK to confirm.
Step 5: Add Controller (dual-controller systems only)
The Add Controller step adds a second controller to a Storage Center.
Figure 7. Add Controller
If... Then...
You are installing a second controller Click Add Controller. The Controller Information dialog
appears. Go to Controller IP Information on page 14.
You are not installing a second controller
(you have a single-controller system)
Click Continue Setup. Go to Step 6: Time Settings on
page 16.
Przeglądanie stron 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 69 70

Komentarze do niniejszej Instrukcji

Brak uwag