Dell Lifecycle Controller 2 Version 1.3.0 Instrukcja Użytkownika Strona 125

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 157
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 124
Lifecycle Controller IntegrationBest Practices Specification
125
ProfileRequireLicenseStatus = LICENSED
RegisteredName = License Management
RegisteredOrganization = 1
RegisteredVersion = 1.0.0
27 Power Supply Profile Use Cases
27.1 Discovery of Power Supply Profile Support
Use the following procedure below to confirm the existence of Power Supply profile support.
Applies to: LC1.5.0+
Prerequisites for script: none
Script: GetPowerSupplyProfile.win
A) The Lifecycle Controller remote service must be in a “ready” state before executing any
other WSMAN commands. The GetRSStatus() method or the GetRemoteServicesAPIStatus()
method may be used depending on the version of the LC Management registered profile.
B) GetLCRegisteredProfiles(): ENUMERATE the DCIM_LCRegisteredProfile class to view all
registered profiles. See section 2.2 for a definition of
ENUMERATE .
C) Search for “RegisteredName=Power Supply” and note its instanceID to use in step D)
D) GetLCRegisteredProfile(): GET the DCIM_LCRegisteredProfile instance using the
InstanceID from C). See Section 2.3 for a definition of
GET.
Results for the InstanceID of DCIM:PowerSupply:2.0.0 shown below. If no instance is returned,
the profile is not supported.
DCIM_LCRegisteredProfile
AdvertiseTypeDescriptions = WS-Identify
AdvertiseTypeDescriptions = Interop Namespace
AdvertiseTypes = 1
AdvertiseTypes = 1
InstanceID = DCIM:PowerSupply:2.0.0
OtherRegisteredOrganization = DCIM
ProfileRequireLicense = Remote Inventory
ProfileRequireLicenseStatus = LICENSED
RegisteredName = Power Supply
RegisteredOrganization = 1
RegisteredVersion = 2.1.0
Przeglądanie stron 124
1 2 ... 120 121 122 123 124 125 126 127 128 129 130 ... 156 157

Komentarze do niniejszej Instrukcji

Brak uwag