126 Storage Management Message Reference
2335 Controller
event log: %1
Warni ng /
Non-critical
Cause: The %1 indicates a
substitution variable. The text for
this substitution variable is generated
by the controller and is displayed
with the alert in the Alert Log. This
text is from events in the controller
event log that were generated while
Storage Management was not
running. This text can vary
depending on the situation.
Action: If there is a problem, review
the controller event log and the
Server Administrator Alert Log for
significant events or alerts that may
assist in diagnosing the problem.
Check the health of the storage
components. See the hardware
documentation for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
2336 Controller
event log: %1
Critical /
Failure /
Error
Cause: The %1 indicates a
substitution variable. The text for
this substitution variable is generated
by the controller and is displayed
with the alert in the Alert Log. This
text is from events in the controller
event log that were generated while
Storage Management was not
running. This text can vary
depending on the situation.
Action: See the hardware
documentation for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2061
754
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers
Przeglądanie stron 125