Dell OpenManage Server Administrator Version 5.4 Podręcznik Użytkownika Strona 83

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 148
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 82
Storage Management Message Reference 83
2122 Redundancy
degraded
Warning /
Non-critical
Cause: One or more of the enclosure
components has failed.
For example, a fan or power supply
may have failed. Although the
enclosure is currently operational, the
failure of additional components
could cause the enclosure to fail.
Action: Identify and replace the failed
component. To identify the failed
component, select the enclosure in
the tree view and click the Health
subtab. Any failed component will be
identified with a red "X" on the
enclosure’s Health subtab.
Alternatively, you can select the
Storage object and click the Health
subtab. The controller status
displayed on the Health subtab
indicates whether a controller has a
failed or degraded component.
See the enclosure documentation for
information on replacing enclosure
components and for other diagnostic
information.
Clear Alert Status: 2124.
Related Alert Number: 2048
LRA Number: 2090
1305
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers
Przeglądanie stron 82
1 2 ... 78 79 80 81 82 83 84 85 86 87 88 ... 147 148

Komentarze do niniejszej Instrukcji

Brak uwag