70 Storage Management Message Reference
2067 Virtual disk
check
consistency
cancelled
Ok / Normal Cause: The check consistency
operation cancelled because a
physical disk in the array has failed or
because a user cancelled the check
consistency operation.
Action: If the physical disk failed, then
replace the physical disk. You can
identify which disk failed by locating
the disk that has a red “X” for its
status. Perform a rescan after
replacing the disk. When performing
a consistency check, be aware that
the consistency check can take a long
time. The time it takes depends on
the size of the physical disk or
the virtual disk.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1201
2070 Virtual disk
initialization
cancelled
Ok / Normal Cause: The virtual disk initialization
cancelled because a physical disk
included in the virtual disk has failed
or because a user cancelled the virtual
disk initialization.
Action: If a physical disk failed, then
replace the physical disk. You can
identify which disk has failed by
locating the disk that has a red “X”
for its status. Perform a rescan after
replacing the disk. Restart the format
physical disk operation. Restart the
virtual disk initialization.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1201
2074 Physical disk
rebuild
cancelled
Ok / Normal Cause: A user has cancelled the
rebuild operation.
Action: Restart the rebuild operation.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
901
Table 4-4. Storage Management Messages (continued)