11. To configure Colubris-only settings in this device group, locate the Colubris section and define the required
fields. Table 68 describes the settings and default values.
12. To configure Symbol-only settings, l
ocate the Symbol section and define the required fields. Table 69
describes the settings and default values.
13. To configure Enterasys R2 settings, locate
the Enterasys R2 section and define the required fields. Table 69
describes the settings and default values.
14. Click Save wh
en radio configurations as described above are complete, or click Save and Apply to retain
changes and push them to network devices. Click Revert to return to the last saved changes.
Table 68 Colubri
s-only Fields and Default Values
Setting Default Description
Rogue Scanning Yes If enabled, Colubris access points in the group will passively scan for rogue access
points at the specified interval. This rogue scan will not break a user’s association
to the network.
Rogue Scanning Interval
(10-6
00 secs)
600 If rogue scanning is enabled, this setting controls the frequency with which scans
are conducted (in minutes). Frequent scans provide the greatest security, but AP
performance and throughput available to user devices may be impacted modestly
during a rogue scan.
Automatic Channel Interval 12 Hours Sets the frequency by which APs monitor radio channels for availability and
ac
tivity.
First Radio 802.11b only
1 Mbps
Sets the operational mode and multicast data rate for the first Colubris radio.
Second Radio
(CN330 only)
802.11b only
1 Mbps
Sets the operational mode and multicast data
rate for the second Colubris radio,
supported only for the Colubris CN330.
Table 69 Symbol-only Fields and Default Values
Setting Default Description
Rogue Scanning Yes If enabled, Symbol access points with 3.9.2 or later firmware in the group will
passively scan for rogue access points at the specified interval. This rogue scan
will not break a user’s association to the network.
Rogue Scanning Interval (5-
480
min)
240 If rogue scanning is enabled, this setting controls the frequency with which scans
are conducted (in minutes). Frequent scans provide the greatest security, but AP
performance and throughput available to user devices may be impacted modestly
during a rogue scan.
Table 70 Enterasys Section Fields and Default Values
Setting Default Description
Operational Mode 802.11b +
802.11g
Drop-down menu defines the 802.11 settings to support with the Enterasys radio
devices in this group. Supported options are as follows:
802.11a only
802.11b only
802.11g only
802.11b + 802.11g