1. To remove the cooling shroud, locate the release tab on the shroud edge that is nearest to the adjacent system board shroud. See Figure3-6.
2. Pull up on the release tab to release the memory cooling shroud.
3. Unseat the shroud from the securing tabs located on the periphery of the shroud.
4. Carefully lift the shroud straight up to disengage it from the system board, and then lift the shroud away from the system.
Figure 3-6. Memory Cooling Shroud
Replacing the Memory Cooling Shroud
1. To install the memory cooling shroud, align the shroud directly over the memory modules and the processors.
2. Using the interior system board cooling shroud as a guide, slowly lower the shroud straight down onto the system, directly over the processors and
memory modules.
3. Gentlypressaroundtheperipheryoftheshrouduntilitengageswiththeexternaltabsandsnapsintoplace.
Power Supplies
Your system supports two power supplies rated at an output of 670 W.
Removing a Power Supply
1. Disconnect the power cable from the power source.
2. Disconnect the power cable from the power supply and remove the cable from the cable retention bracket.
3. Release the locking tab on the left side of the power supply by pressing in toward the right until the power supply is released from the chassis. See
Figure3-7.
NOTICE: The system requires one power supply for the system to operate normally. The system is in the redundant mode when two power supplies
are installed and both power supplies are connected to an AC power source. Remove and replace only one power supply at a time in a system that is
powered on. Operating the system with only one power supply installed and without a power supply blank installed for extended periods of time can
cause the system to overheat.
NOTICE: If you connect the system to a power source in the range of 120 to 220 VAC, the second power supply serves as a redundant, hot-plug power
source.
NOTE: On your rack system, you may have to unlatch and lift the cable management arm if it interferes with power supply removal. For information
about the cable management arm, see the system's Rack Installation Guide.
NOTICE: Onaracksystem,youmayneedtotemporarilyunlatchandliftthecablemanagementarm.Forinformationaboutthecable
management arm, see the system's Rack Installation Guide.