194 omconfig storage Commands
Complete Syntax
omconfig storage pdisk action=unblink controller=
id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical
disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to unblink physical disk 0 on connector 0 of
controller 1. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers
To unblink the physical disk described in this example, type:
omconfig storage pdisk action=unblink controller=1
pdisk=0:0
Example for SAS Controllers
To unblink the physical disk described in this example, type:
omconfig storage pdisk action=unblink controller=1
pdisk=0:2:0
omconfig Prepare to Remove Physical Disk
Use the following omconfig command syntax to prepare a physical disk for
removal:
Complete Syntax
omconfig storage pdisk action=remove controller=id
pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical
disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.