228 omconfig storage Commands
[writepolicy=<wb| wt| wc| nwc>] Parameter (Optional)
Different controllers support different write policies. Table 8-9 indicates how
to specify the [writepolicy=<wb| wt| wc| nwc | fwb>] parameter for each
of the write policies.
[name=<string>] Parameter (Optional)
Use this parameter to specify a name for the virtual disk. For example:
name=VirtualDisk1
[spanlength=<n>] Parameter (Required for RAID 50 and RAID 60 and optional for
RAID 10)
Use this parameter to specify the number of physical disks to be included in
each stripe.
This parameter only applies to RAID-50 virtual disks. If you are
not creating a RAID-50 virtual disk, do not specify this parameter. For
example:
spanlength=3
For RAID 10 on SAS controllers with firmware version 6.1 and later,
spanlength is optional. Also, you can now specify the spanlength as an
even number with a maximum of 8 spans with 32 physical disks each. For
example,
omconfig storage controller action=createvdisk
controller=1 raid=r10 size=min pdisk=
1:1:0,1:1:1,1:1:3,1:1:4,1:1:6,1:1:7,1:1:8,1:1:9
spanlength=4
Table 8-9. Write Policy Parameters
Write Policy writepolicy=wb | wt | wc | fwb | nwc Parameter
Specification
Write–back cache writepolicy=wb
Write–through cache writepolicy=wt
Write cache writepolicy=wc
Force write back writepolicy=fwb
No write cache writepolicy=nwc